SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Larsson Elna Marie) ;pers:(Smedby Örjan)"

Sökning: WFRF:(Larsson Elna Marie) > Smedby Örjan

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Blystad, Ida, 1972- (författare)
  • Clinical Applications of Synthetic MRI of the Brain
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Magnetic Resonance Imaging (MRI) has a high soft-tissue contrast with a high sensitivity for detecting pathological changes in the brain. Conventional MRI is a time-consuming method with multiple scans that relies on the visual assessment of the neuroradiologist. Synthetic MRI uses one scan to produce conventional images, but also quantitative maps based on relaxometry, that can be used to quantitatively analyse tissue properties and pathological changes. The studies presented here apply the use of synthetic MRI of the brain in different clinical settings.In the first study, synthetic MR images were compared to conventional MR images in 22 patients. The contrast, the contrast-to-noise ratio, and the diagnostic quality were assessed. Image quality was perceived to be inferior in the synthetic images, but synthetic images agreed with the clinical diagnoses to the same extent as the conventional images.Patients with early multiple sclerosis were analysed in the second study. In patients with multiple sclerosis, contrast-enhancing white matter lesions are a sign of active disease and can indicate a need for a change in therapy. Gadolinium-based contrast agents are used to detect active lesions, but concern has been raised regarding the long-term effects of repeated use of gadolinium. In this study, relaxometry was used to evaluate whether pre-contrast injection tissue-relaxation rates and proton density can identify active lesions without gadolinium. The findings suggest that active lesions often have relaxation times and proton density that differ from non-enhancing lesions, but with some overlap. This makes it difficult to replace gadolinium-based contrast agent injection with synthetic MRI in the monitoring of MS patients.Malignant gliomas are primary brain tumours with contrast enhancement due to a defective blood-brain barrier. However, they also grow in an infiltrative, diffuse manner, making it difficult to clearly delineate them from surrounding normal brain tissue in the diagnostic workup, at surgery, and during follow-up. The contrast-enhancing part of the tumour is easily visualised, but not the diffuse infiltration. In studies three and four, synthetic MRI was used to analyse the peritumoral area of malignant gliomas, and revealed quantitative findings regarding peritumoral relaxation changes and non-visible contrast enhancement suggestive of non-visible infiltrative tumour growth.In conclusion, synthetic MRI provides quantitative information about the brain tissue and this could improve the diagnosis and treatment for patients.
  •  
2.
  • Blystad, Ida, et al. (författare)
  • Synthetic MRI of the brain in a clinical setting
  • 2012
  • Ingår i: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455. ; 53:10, s. 1158-1163
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Conventional magnetic resonance imaging (MRI) has relatively long scan times for routine examinations, and the signal intensity of the images is related to the specific MR scanner settings. Due to scanner imperfections and automatic optimizations, it is impossible to compare images in terms of absolute image intensity. Synthetic MRI, a method to generate conventional images based on MR quantification, potentially both decreases examination time and enables quantitative measurements.PURPOSE:To evaluate synthetic MRI of the brain in a clinical setting by assessment of the contrast, the contrast-to-noise ratio (CNR), and the diagnostic quality compared with conventional MR images.MATERIAL AND METHODS:Twenty-two patients had synthetic imaging added to their clinical MR examination. In each patient, 12 regions of interest were placed in the brain images to measure contrast and CNR. Furthermore, general image quality, probable diagnosis, and lesion conspicuity were investigated.RESULTS:Synthetic T1-weighted turbo spin echo and T2-weighted turbo spin echo images had higher contrast but also a higher level of noise, resulting in a similar CNR compared with conventional images. Synthetic T2-weighted FLAIR images had lower contrast and a higher level of noise, which led to a lower CNR. Synthetic images were generally assessed to be of inferior image quality, but agreed with the clinical diagnosis to the same extent as the conventional images. Lesion conspicuity was higher in the synthetic T1-weighted images, which also had a better agreement with the clinical diagnoses than the conventional T1-weighted images.CONCLUSION:Synthetic MR can potentially shorten the MR examination time. Even though the image quality is perceived to be inferior, synthetic images agreed with the clinical diagnosis to the same extent as the conventional images in this study.
  •  
3.
  • Blystad, Ida, et al. (författare)
  • Quantitative MRI for Analysis of Active Multiple Sclerosis Lesions without Gadolinium-Based Contrast Agent
  • 2016
  • Ingår i: American Journal of Neuroradiology. - : American Society of Neuroradiology (ASNR). - 0195-6108 .- 1936-959X. ; 37:1, s. 94-100
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: Contrast-enhancing MS lesions are important markers of active inflammation in the diagnostic work-up of MS and in disease monitoring with MR imaging. Because intravenous contrast agents involve an expense and a potential risk of adverse events, it would be desirable to identify active lesions without using a contrast agent. The purpose of this study was to evaluate whether pre-contrast injection tissue-relaxation rates and proton density of MS lesions, by using a new quantitative MR imaging sequence, can identify active lesions.MATERIALS AND METHODS: Forty-four patients with a clinical suspicion of MS were studied. MR imaging with a standard clinical MS protocol and a quantitative MR imaging sequence was performed at inclusion (baseline) and after 1 year. ROIs were placed in MS lesions, classified as nonenhancing or enhancing. Longitudinal and transverse relaxation rates, as well as proton density were obtained from the quantitative MR imaging sequence. Statistical analyses of ROI values were performed by using a mixed linear model, logistic regression, and receiver operating characteristic analysis.RESULTS: Enhancing lesions had a significantly (P < .001) higher mean longitudinal relaxation rate (1.22 ± 0.36 versus 0.89 ± 0.24), a higher mean transverse relaxation rate (9.8 ± 2.6 versus 7.4 ± 1.9), and a lower mean proton density (77 ± 11.2 versus 90 ± 8.4) than nonenhancing lesions. An area under the receiver operating characteristic curve value of 0.832 was obtained.CONCLUSIONS: Contrast-enhancing MS lesions often have proton density and relaxation times that differ from those in nonenhancing lesions, with lower proton density and shorter relaxation times in enhancing lesions compared with nonenhancing lesions.
  •  
4.
  • Blystad, Ida, 1972-, et al. (författare)
  • Quantitative MRI for analysis of peritumoral edema in malignant gliomas
  • 2017
  • Ingår i: PLOS ONE. - : Public Library of Science. - 1932-6203. ; 12:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose Damage to the blood-brain barrier with subsequent contrast enhancement is a hallmark of glioblastoma. Non-enhancing tumor invasion into the peritumoral edema is, however, not usually visible on conventional magnetic resonance imaging. New quantitative techniques using relaxometry offer additional information about tissue properties. The aim of this study was to evaluate longitudinal relaxation R-1, transverse relaxation R-2, and proton density in the peritumoral edema in a group of patients with malignant glioma before surgery to assess whether relaxometry can detect changes not visible on conventional images. Methods In a prospective study, 24 patients with suspected malignant glioma were examined before surgery. A standard MRI protocol was used with the addition of a quantitative MR method (MAGIC), which measured R-1, R-2, and proton density. The diagnosis of malignant glioma was confirmed after biopsy/surgery. In 19 patients synthetic MR images were then created from the MAGIC scan, and ROIs were placed in the peritumoral edema to obtain the quantitative values. Dynamic susceptibility contrast perfusion was used to obtain cerebral blood volume (rCBV) data of the peritumoral edema. Voxel-based statistical analysis was performed using a mixed linear model. Results R-1, R-2, and rCBV decrease with increasing distance from the contrast-enhancing part of the tumor. There is a significant increase in R1 gradient after contrast agent injection (P<.0001). There is a heterogeneous pattern of relaxation values in the peritumoral edema adjacent to the contrast-enhancing part of the tumor. Conclusion Quantitative analysis with relaxometry of peritumoral edema in malignant gliomas detects tissue changes not visualized on conventional MR images. The finding of decreasing R-1 and R-2 means shorter relaxation times closer to the tumor, which could reflect tumor invasion into the peritumoral edema. However, these findings need to be validated in the future.
  •  
5.
  • Blystad, Ida, 1972-, et al. (författare)
  • Quantitative MRI using relaxometry in malignant gliomas detects contrast enhancement in peritumoral oedema
  • 2020
  • Ingår i: Scientific Reports. - : Springer Nature. - 2045-2322. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Malignant gliomas are primary brain tumours with an infiltrative growth pattern, often with contrast enhancement on magnetic resonance imaging (MRI). However, it is well known that tumour infiltration extends beyond the visible contrast enhancement. The aim of this study was to investigate if there is contrast enhancement not detected visually in the peritumoral oedema of malignant gliomas by using relaxometry with synthetic MRI. 25 patients who had brain tumours with a radiological appearance of malignant glioma were prospectively included. A quantitative MR-sequence measuring longitudinal relaxation (R-1), transverse relaxation (R-2) and proton density (PD), was added to the standard MRI protocol before surgery. Five patients were excluded, and in 20 patients, synthetic MR images were created from the quantitative scans. Manual regions of interest (ROIs) outlined the visibly contrast-enhancing border of the tumours and the peritumoral area. Contrast enhancement was quantified by subtraction of native images from post GD-images, creating an R-1-difference-map. The quantitative R-1-difference-maps showed significant contrast enhancement in the peritumoral area (0.047) compared to normal appearing white matter (0.032), p = 0.048. Relaxometry detects contrast enhancement in the peritumoral area of malignant gliomas. This could represent infiltrative tumour growth.
  •  
6.
  • Nordanskog, Pia, 1971- (författare)
  • On electroconvulsive therapy in depression : Clinical, cognitive and neurobiological aspects
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Electroconvulsive therapy (ECT) is used worldwide to treat severe mental disorders. The most common mental disorder, and the third leading cause of disease burden in the world is depression. The clinical efficacy of ECT for severe depression is well-established. However, both the pathophysiology of depression and the mechanism of action of ECT remain elusive.The main aims of this thesis are to address the following issues: 1) the use and practice of ECT in Sweden has not been systematically evaluated since 1975, 2) cognitive side-effects (memory disturbances) are a major concern with ECT and 3) the mechanism of action of ECT remain elusive. The neurobiological aspects of ECT focus on two hypotheses. First, the recent years´ preclinical studies that have provided evidence that ECT induces hippocampal cell proliferation, including neurogenesis. Second, that enhanced functional inhibition of neuronal activity is a key feature.Current use and practice of ECT in Sweden (paper I) is based on data from the national quality register for ECT, the mandatory patient register of the National Board of Health and Welfare and a survey. Treated person rate (TPR) in Sweden 2013 was found to be 41 individuals / 100 000, and thus unchanged since the latest systematic investigation in Sweden 1975. In more than 70% of treatment series the indication was a depressive episode. The selection of patients for ECT and treatment technique in Sweden was similar to that in other western countries, but the consent procedure and the involvement of nurses and nursing assistants in the delivery of ECT differ. Data also shows that there is room for improvement in both the specificity of use and availability of ECT.The second study in this thesis is a longitudinal observational trial where 12 (paper II and III) and 14 (paper IV) patients with depression referred for ECT were investigated. Patients underwent a 3 T MRI structural scanning and DSC-MRI perfusion, a neuropsychological test battery and clinical ratings before ECT, within one to two weeks after ECT and after 6 and 12 months.  In line with preclinical findings and the plasticity hypothesis of mechanism of action of ECT, the hippocampal volume increased after ECT in patients with depression. However, this increase was transient and returned to baseline levels within 6 months. No correlation was found between volumetric changes and clinical effect or cognitive outcome. Instead our results suggested an association to the number of treatments, without relation to the side of stimulation. A right-sided decrease in frontal blood flow distinguished remission from non-remission after ECT. There were significant impairments in verbal episodic memory and verbal fluency within one week after ending the ECT course, but these impairments were transient and no persistent cognitive impairments were seen during the follow-up.In summary, this thesis present the first update on the use and practice of ECT in Sweden in the last 40 years as well as a pioneering MRI-study on the hippocampal volume increase in the treatment of depression with ECT. Supportive to earlier findings we also found the cognitive side-effects that are measurable after ECT to be transient. Furthermore, we found that a decreased frontal blood flow is of importance for the anti-depressive response to ECT.
  •  
7.
  • Persson, Anders, 1953-, et al. (författare)
  • Volume rendering compared with maximum intensity projection for magnetic resonance angiography measurements of the abdominal aorta
  • 2004
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 45:4, s. 453-459
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To compare the volume rendering technique (VRT) with maximum intensity projection (MIP) for aortic diameter measurements in MR angiography (MRA) data sets.Material and Methods: Existing contrast-enhanced 3-dimensional MRA and digital subtraction angiography (DSA) data sets from 20 patients were analyzed. In each MRA data set, two aortic diameters were measured using MIP and VRT. Agreement with DSA measurements, dependence on rendering parameters, and interobserver agreement were assessed.Results: Diameters measured on MIP with fixed parameters showed no significant difference compared with DSA and with freely selected parameters a slight overestimation relative to DSA. Diameters measured on VRT were larger than on DSA. For both MIP and VRT, the measurements depended on the chosen parameters. The error relative to DSA was larger for VRT than for MIP with fixed parameters but not with freely chosen parameters. Interobserver agreement did not differ significantly.Conclusions: VRT is not suitable for diameter measurements of the abdominal aorta with fixed parameter settings but may be useful with user-selected settings.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy