SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Li J) ;lar1:(ri)"

Sökning: WFRF:(Li J) > RISE

  • Resultat 1-10 av 44
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Wang, J., et al. (författare)
  • Final report of the CCQM-K145 : Toxic and essential elements in bovine liver
  • 2020
  • Ingår i: Metrologia. - : IOP Publishing Ltd. - 0026-1394 .- 1681-7575. ; 57:1 A
  • Tidskriftsartikel (refereegranskat)abstract
    • Liver plays a major role in metabolism and acts as a source of energy for the body by storing glycogen. With the growing interest and investigation in the biological effects in recent years, it is important and necessary to develop accurate and comparable analytical methods for elements in bio-samples. It has, however, been 10 years since the tissue sample (bovine liver) of CCQM-K49 key comparison. The purpose of CCQM-K145 is to ensure the comparable and traceable measurement results for essential and toxic elements such as P, S, Zn, Mn, Ni, Mo, Sr, Cr, Co, Pb, As and Hg in bovine liver among NMIs and other designated measurement bodies worldwide. The comparison was agreed by IAWG as 6th IAWG Benchmarking Exercise with Zn and Ni as exemplary elements at the meeting in Korea in the early October 2016. The results of CCQM-K145 are expected to cover the measurement capability and support CMCs claiming for inorganic elements in the similar biological tissue materials and food samples. 30 NMIs and DIs registered in CCQM-K145. With respect to the methodology, a variety of techniques such as IDMS, ICP-OES, ICP-MS(non-ID), AAS and NAA were adopted by the participants. For Zn, Ni, Sr, Pb and Hg measurements, most participants chose ID-ICP-MS method, which showed the better performance in terms of consistency and reliability of the measurement results. In aspect of the traceability for the measurement results in CCQM-K145, most participants used their own (in house) CRMs or other NMI's CRMs to guarantee trace to SI unit. Most participants used similar matrix CRMs for quality control or method validation. Base on different statistic way to calculate the reference mass fraction values and associated uncertainties for each measurand, removal of the suspected extreme values, and discussion at the IAWG meetings, the median values are proposed as the KCRV for Zn, Ni, Mn, Mo, Cr, Pb and Hg; the arithmetic mean values are proposed as the KCRV for P, S, Sr, Co and As. In general, the performances of the majority of CCQM-K145 participants are very good, illustrating their measurement capabilities for Zn, Ni, P, S, Mn, Mo, Sr, Cr, As, Co, Pb and Hg in a complex biological tissue matrix. Bovine liver contains many kinds of nutrients and microelements, it can be regarded as a typical representative material of biological tissue and food. In CCQM-K145, the analytes involved alkali metals and transition elements, metalloids/semi-metals and non metals with a range of mass fraction from mg/g to μg/kg. CCQM-K145 also tested the ability of NMIs/DIs to determine elements that were easy to be lost and polluted, and interfered significantly. The chemical pretreatment methods of samples used in the comparison is suitable for general food and biological matrix samples. A variety of measurement methods used in the comparison represent the main instrumental technology for elemental analysis. Therefore, for supporting CMC claim, CCQM-K145 is readily applicable to measurement of more elements in a wide range of biological materials (including liquids and solids) and meat products. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
  •  
2.
  • Buker, O., et al. (författare)
  • Metrological support for LNG custody transfer and transport
  • 2016
  • Ingår i: Proceedings of the 17th International Flow Measurement Conference (FLOMEKO 2016).
  • Konferensbidrag (refereegranskat)abstract
    • In the framework of the ongoing EMRP Joint Research Project (JRP) ENG 60 “Metrology for LNG” (2014-2017), co-funded by the European Union, a number of metrological challenges associated with custody transfer and transport of LNG will be faced. The project consists of four technical work packages (WP), whereby the main objective is to reduce the measurement uncertainty of LNG custody transfer by a factor two. The focus in WP1 is the design and development of a traceable mid-scale calibration standard for LNG mass and volume flow. The goal is to provide traceable mass and volume flow calibrations up to 400 m3/h (180000 kg/h). In WP2, the emphasis is on the development and validation of a LNG sampling and composition measurement reference standard, consisting of sampler, vaporizer, gas standards, and gas chromatography (GC), which will be used to  test and calibrate commercially available LNG sampling and composition measurement systems. The priority in WP3 is given to the development and validation of a method for the determination of the methane number, including correlations based on the LNG composition and corrections for traces of nitrogen and higher hydrocarbons. Since physical properties and quantities play an important role in LNG custody transfer, WP4 comprises reference quality density measurements of LNG to validate and improve models for LNG density predictions, the uncertainty evaluation of enthalpy and calorific value calculations and the development of a novel cryogenic sensor for the simultaneous measurement of speed-of-sound and density. The present paper gives an overview of recently achieved objectives within the project and provides an outlook to future activities.
  •  
3.
  • Hallström, J., et al. (författare)
  • Worldwide comparison of lightning impulse voltage measuring systems at the 400-kV level
  • 2007
  • Ingår i: IEEE Transactions on Instrumentation and Measurement. - 0018-9456 .- 1557-9662. ; 56:2, s. 388-391
  • Tidskriftsartikel (refereegranskat)abstract
    • An international comparison of lightning and switching impulse voltage measuring systems was arranged and coordinated by the Helsinki University of Technology (MIKES-TKK), Espoo, Finland, between 1999 and 2002. The number of participants was 26, including the coordinator. This paper summarizes the results obtained by those eight National Metrology Institutes that participated in the comparison. A 400-kV transfer reference measuring system for measuring lightning impulse voltages was prepared by the coordinator. In addition, a 1-kV impulse voltage calibrator system, including calibrators for both standard lightning and switching impulses, was circulated. © 2007 IEEE.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Larzelere, W, et al. (författare)
  • MEASUREMENT OF THE INTERNAL INDUCTANCE OF IMPULSEVOLTAGE GENERATORS AND THE LIMITS OF LI FRONT TIMES
  • 2017
  • Konferensbidrag (refereegranskat)abstract
    • The recent push to higher testing voltages for research and production tests onUHV system components rated above 800kV class has led to difficulties in achieving thestandard waveshapes as required by IEC60060 Parts 1 and 2 and other existing IEC,IEEE/ANSI and other standards. One of the limiting components in achieving themaximum capacitive loading on an impulse generator for standard lightning impulse fronttimes is the inductance of the circuit. The total inductance of the circuit is comprised ofthe internal inductance of the impulse generator and the inductance of the loop toconnect to the load. The higher the voltage class of test objects, the larger the loop,yielding more inductance that in turn, reduces the test capacitance that can be connectedand still remain inside the overshoot requirements of the standards. The internalinductance of the impulse generator is comprised of the wiring of the stages and thestage capacitor inductance and/or the inductance of the waveshaping resistors. Thispaper shows the results of methods to measure and calculate the internal inductance ofseveral impulse generators and we review the formulas for calculating the maximum loadof an impulse generator with a given internal inductance. We believe these methods givemore realistic values than adding up nameplate inductance values from an impulsegenerator. The paper also reviews the pros and cons of higher stage capacitances inimpulse generators to test larger loads that are ultimately limited by the circuit inductancevalue. The intent of this paper is to assist in the revision of future IEC and IEEE standardsfor impulse testing apparatus in the UHV range
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 44

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy