SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lim J) ;lar1:(ri)"

Sökning: WFRF:(Lim J) > RISE

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Wang, J., et al. (författare)
  • Final report of the CCQM-K145 : Toxic and essential elements in bovine liver
  • 2020
  • Ingår i: Metrologia. - : IOP Publishing Ltd. - 0026-1394 .- 1681-7575. ; 57:1 A
  • Tidskriftsartikel (refereegranskat)abstract
    • Liver plays a major role in metabolism and acts as a source of energy for the body by storing glycogen. With the growing interest and investigation in the biological effects in recent years, it is important and necessary to develop accurate and comparable analytical methods for elements in bio-samples. It has, however, been 10 years since the tissue sample (bovine liver) of CCQM-K49 key comparison. The purpose of CCQM-K145 is to ensure the comparable and traceable measurement results for essential and toxic elements such as P, S, Zn, Mn, Ni, Mo, Sr, Cr, Co, Pb, As and Hg in bovine liver among NMIs and other designated measurement bodies worldwide. The comparison was agreed by IAWG as 6th IAWG Benchmarking Exercise with Zn and Ni as exemplary elements at the meeting in Korea in the early October 2016. The results of CCQM-K145 are expected to cover the measurement capability and support CMCs claiming for inorganic elements in the similar biological tissue materials and food samples. 30 NMIs and DIs registered in CCQM-K145. With respect to the methodology, a variety of techniques such as IDMS, ICP-OES, ICP-MS(non-ID), AAS and NAA were adopted by the participants. For Zn, Ni, Sr, Pb and Hg measurements, most participants chose ID-ICP-MS method, which showed the better performance in terms of consistency and reliability of the measurement results. In aspect of the traceability for the measurement results in CCQM-K145, most participants used their own (in house) CRMs or other NMI's CRMs to guarantee trace to SI unit. Most participants used similar matrix CRMs for quality control or method validation. Base on different statistic way to calculate the reference mass fraction values and associated uncertainties for each measurand, removal of the suspected extreme values, and discussion at the IAWG meetings, the median values are proposed as the KCRV for Zn, Ni, Mn, Mo, Cr, Pb and Hg; the arithmetic mean values are proposed as the KCRV for P, S, Sr, Co and As. In general, the performances of the majority of CCQM-K145 participants are very good, illustrating their measurement capabilities for Zn, Ni, P, S, Mn, Mo, Sr, Cr, As, Co, Pb and Hg in a complex biological tissue matrix. Bovine liver contains many kinds of nutrients and microelements, it can be regarded as a typical representative material of biological tissue and food. In CCQM-K145, the analytes involved alkali metals and transition elements, metalloids/semi-metals and non metals with a range of mass fraction from mg/g to μg/kg. CCQM-K145 also tested the ability of NMIs/DIs to determine elements that were easy to be lost and polluted, and interfered significantly. The chemical pretreatment methods of samples used in the comparison is suitable for general food and biological matrix samples. A variety of measurement methods used in the comparison represent the main instrumental technology for elemental analysis. Therefore, for supporting CMC claim, CCQM-K145 is readily applicable to measurement of more elements in a wide range of biological materials (including liquids and solids) and meat products. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
  •  
2.
  •  
3.
  • Agostini, Marco, 1987, et al. (författare)
  • Free-Standing 3D-Sponged Nanofiber Electrodes for Ultrahigh-Rate Energy-Storage Devices
  • 2018
  • Ingår i: ACS Applied Materials & Interfaces. - : American Chemical Society (ACS). - 1944-8252 .- 1944-8244. ; 10:40, s. 34140-34146
  • Tidskriftsartikel (refereegranskat)abstract
    • We have designed a self-standing anode built-up from highly conductive 3D-sponged nanofibers, that is, with no current collectors, binders, or additional conductive agents. The small diameter of the fibers combined with an internal spongelike porosity results in short distances for lithium-ion diffusion and 3D pathways that facilitate the electronic conduction. Moreover, functional groups at the fiber surfaces lead to the formation of a stable solid-electrolyte interphase. We demonstrate that this anode enables the operation of Li-cells at specific currents as high as 20 A g-1 (approx. 50C) with excellent cycling stability and an energy density which is >50% higher than what is obtained with a commercial graphite anode.
  •  
4.
  •  
5.
  • Lang, Jenny, et al. (författare)
  • Reliability study of a RF power amplifier with GaN-on-SiC HEMTs
  • 2016
  • Ingår i: ECS Transactions. - Pennington, N.J. : The Electrochemical Society. - 9781607685395 ; , s. 49-59
  • Konferensbidrag (refereegranskat)abstract
    • RF power amplifier demonstrators containing each one GaN-on- SiC, HEMT, CHZ015A-QEG, from UMS in SMD quad-flat noleads package (QFN) were subjected to thermal cycles (TC) and power cycles (PC) and evaluated electrically, thermally and structurally. Two types of lead-free solders (Sn63Pb36Ag2 and SnAgCu (SAC305)) and two types of TIM materials (NanoTIM and TgonTM 805) for PCB attachment to liquid cold plate were tested for thermo-mechanical reliability. Changes in electrical performance of the devices namely reduction of the current saturation value, threshold voltage shift, increase of the leakage current and degradation of the HF performance were observed as a result of an accumulated current stress during PC. No significant changes in the investigated solder or TIM materials were observed.
  •  
6.
  • Lang, Jenny, et al. (författare)
  • Reliability Study of GaN-onSiC HEMT RF Power Amplifiers
  • 2018
  • Ingår i: Advances in Technology Innovation. ; 3:4, s. 157-165
  • Tidskriftsartikel (refereegranskat)abstract
    • The RF power amplifier demonstrators containing each one GaN-on-SiC, HEMT, CHZ015A-QEG, from UMSin SMD quad-flat no-leads package (QFN) were subjected to thermal cycles (TC) and power cycles (PC) andevaluated electrically, thermally and structurally. Two types of solders, Sn63Pb36Ag2 and lead-free SnAgCu(SAC305), and two types of TIM materials, NanoTIM and TgonTM 805, for PCB attachment to the liquid cold platewere tested for thermo-mechanical reliability. Changes in the electrical performance of the devices, namely thereduction of the current saturation value, threshold voltage shift, increase of the leakage current and degradation ofthe HF performance were observed as a result of an accumulated current stress during PC. No significant changes inthe investigated solder or TIM materials were observed.
  •  
7.
  • Lang, Jenny, et al. (författare)
  • Thermo-mechanical reliability and performance degradation of a lead-free RF power amplifier with GaN-on-SiC HEMTs
  • 2017
  • Ingår i: Materials Science Forum. - : Trans Tech Publications. - 9783035710434 ; , s. 715-718
  • Konferensbidrag (refereegranskat)abstract
    • RF power amplifier demonstrators containing each one GaN-on-SiC, HEMT, CHZ015AQEG, from UMS in SMD quad-flat no-leads package (QFN) were subjected to thermal cycles (TC) and power cycles (PC) followed by electrical, thermal and structural evaluation. Two types of solders i.e. Sn63Pb36Ag2 and lead-free SnAgCu (SAC305) and two types of TIM materials (NanoTIM and TgonTM 805) for PCB attachment to liquid cold plate were tested for thermomechanical reliability. Changes in electrical performance of the devices namely reduction of the current saturation value, threshold voltage shift, increase of the leakage current and degradation of the HF performance were observed as a result of an accumulated current stress during PC. No significant changes in the investigated solder or TIM materials were observed.
  •  
8.
  •  
9.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy