SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lindahl Bertil) ;pers:(Plebani Mario)"

Sökning: WFRF:(Lindahl Bertil) > Plebani Mario

  • Resultat 1-10 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Body, Richard, et al. (författare)
  • The Use of Very Low Concentrations of High-sensitivity Troponin T to Rule Out Acute Myocardial Infarction Using a Single Blood Test
  • 2016
  • Ingår i: Academic Emergency Medicine. - : Wiley. - 1069-6563 .- 1553-2712. ; 23:9, s. 1005-1013
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Recent single-center and retrospective studies suggest that acute myocardial infarction (AMI) could be immediately excluded without serial sampling in patients with initial high-sensitivity cardiac troponin T (hs-cTnT) levels below the limit of detection (LoD) of the assay and no electrocardiogram (ECG) ischemia. Objective: We aimed to determine the external validity of those findings in a multicenter study at 12 sites in nine countries. Methods: TRAPID-AMI was a prospective diagnostic cohort study including patients with suspected cardiac chest pain within 6 hours of peak symptoms. Blood drawn on arrival was centrally tested for hs-cTnT (Roche; 99th percentile = 14 ng/L, LoD = 5 ng/L). All patients underwent serial troponin sampling over 4-14 hours. The primary outcome, prevalent AMI, was adjudicated based on sensitive troponin I (Siemens Ultra) levels. Major adverse cardiac events (MACE) including AMI, death, or rehospitalization for acute coronary syndrome with coronary revascularization were determined after 30 days. Results: We included 1,282 patients, of whom 213 (16.6%) had AMI and 231 (18.0%) developed MACE. Of 560 (43.7%) patients with initial hs-cTnT levels below the LoD, four (0.7%) had AMI. In total, 471 (36.7%) patients had both initial hs-cTnT levels below the LoD and no ECG ischemia. These patients had a 0.4% (n = 2) probability of AMI, giving 99.1% (95% confidence interval [CI] = 96.7% to 99.9%) sensitivity and 99.6% (95% CI = 98.5% to 100.0%) negative predictive value. The incidence of MACE in this group was 1.3% (95% CI = 0.5% to 2.8%). Conclusions: In the absence of ECG ischemia, the detection of very low concentrations of hs-cTnT at admission seems to allow rapid, safe exclusion of AMI in one-third of patients without serial sampling. This could be used alongside careful clinical assessment to help reduce unnecessary hospital admissions.
  •  
2.
  • Giannitsis, Evangelos, et al. (författare)
  • How to use D-dimer in acute cardiovascular care
  • 2017
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 2048-8726 .- 2048-8734. ; 6:1, s. 69-80
  • Tidskriftsartikel (refereegranskat)abstract
    • D-dimer testing is important to aid in the exclusion of venous thromboembolic events (VTEs), including deep venous thrombosis and pulmonary embolism, and it may be used to evaluate suspected aortic dissection. D-dimer is produced upon activation of the coagulation system with the generation and subsequent degradation of cross-linked fibrin by plasmin. Many different assays for D-dimer testing are currently used in routine care. However, these tests are neither standardized nor harmonized. Consequently, only clinically validated assays and assay specific decision limits should be used for routine testing. For the exclusion of pulmonary embolism/deep vein thrombosis, age-adjusted cut-offs are recommend. Clinicians must be aware of the validated use of their hospital's D-dimer assay to avoid inappropriate use of this biomarker in routine care.
  •  
3.
  • Mair, Johannes, et al. (författare)
  • Editor's Choice-What to do when you question cardiac troponin values
  • 2018
  • Ingår i: European Heart Journal. - : SAGE PUBLICATIONS LTD. - 2048-8726 .- 2048-8734. ; 7:6, s. 577-586
  • Tidskriftsartikel (refereegranskat)abstract
    • High-sensitivity cardiac troponin assays enable cardiac troponin measurement with a high degree of analytical sensitivity and a low level of analytical imprecision at the low measuring range. One of the most important advantages of these new assays is that they allow novel, more rapid approaches for ruling in or ruling out acute myocardial infarctions. The increase in the early diagnostic sensitivity of high-sensitivity cardiac troponin assays comes at the cost of a reduced acute myocardial infarction specificity of the biomarker, because more patients with other causes of acute or chronic myocardial injury without overt myocardial ischaemia are detected than with previous cardiac troponin assays. Increased troponin concentrations that do not fit with the clinical presentation are seen in the daily routine, mainly as a result of a variety of pathologies, and if tested in the same sample, even discrepancies between high-sensitivity cardiac troponin I and troponin T test results may sometimes be found as well. In addition, analytically false-positive test results occasionally may occur since no assay is perfect. In this review, we summarise the biochemical, pathophysiological and analytical background of the work-up for such a clinical setting.
  •  
4.
  • Mair, Johannes, et al. (författare)
  • Will sacubitril-valsartan diminish the clinical utility of B-type natriuretic peptide testing in acute cardiac care?
  • 2017
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 2048-8726 .- 2048-8734. ; 6:4, s. 321-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Since the approval of sacubitril-valsartan for the treatment of chronic heart failure with reduced ejection fraction, a commonly raised suspicion is that a wider clinical use of this new drug may diminish the clinical utility of B-type natriuretic peptide testing as sacubitril may interfere with B-type natriuretic peptide clearance. In this education paper we critically assess this hypothesis based on the pathophysiology of the natriuretic peptide system and the limited published data on the effects of neprilysin inhibition on natriuretic peptide plasma concentrations in humans. As the main clinical application of B-type natriuretic peptide testing in acute cardiac care is and will be the rapid rule-out of suspected acute heart failure there is no significant impairment to be expected for B-type natriuretic peptide testing in the acute setting. However, monitoring of chronic heart failure patients on sacubitril-valsartan treatment with B-type natriuretic peptide testing may be impaired. In contrast to N-terminal-proBNP, the current concept that the lower the B-type natriuretic peptide result in chronic heart failure patients, the better the prognosis during treatment monitoring, may no longer be true.
  •  
5.
  • McCord, James, et al. (författare)
  • Prognostic Utility of a Modified HEART Score in Chest Pain Patients in the Emergency Department
  • 2017
  • Ingår i: Circulation. Cardiovascular Quality and Outcomes. - : LIPPINCOTT WILLIAMS & WILKINS. - 1941-7713 .- 1941-7705. ; 10:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Background-The TRAPID-AMI trial study ( High-Sensitivity Troponin-T Assay for Rapid Rule-Out of Acute Myocardial Infarction) evaluated high-sensitivity cardiac troponin-T ( hs-cTnT) in a 1-hour acute myocardial infarction ( AMI) exclusion algorithm. Our study objective was to evaluate the prognostic utility of a modified HEART score ( m-HS) within this trial. Methods and Results-Twelve centers evaluated 1282 patients in the emergency department for possible AMI from 2011 to 2013. Measurements of hs-cTnT ( 99th percentile, 14 ng/L) were performed at 0, 1, 2, and 4 to 14 hours. Evaluation for major adverse cardiac events ( MACEs) occurred at 30 days ( death or AMI). Low-risk patients had an m-HS <= 3 and had either hs-cTnT<14 ng/L over serial testing or had AMI excluded by the 1-hour protocol. By the 1-hour protocol, 777 ( 60%) patients had an AMI excluded. Of those 777 patients, 515 ( 66.3%) patients had an m-HS <= 3, with 1 ( 0.2%) patient having a MACE, and 262 ( 33.7%) patients had an m-HS <= 4, with 6 ( 2.3%) patients having MACEs ( P=0.007). Over 4 to 14 hours, 661 patients had a hs-cTnT<14 ng/L. Of those 661 patients, 413 ( 62.5%) patients had an m-HS <= 3, with 1 ( 0.2%) patient having a MACE, and 248 ( 37.5%) patients had an m-HS >= 4, with 5 ( 2.0%) patients having MACEs ( P=0.03). Conclusions-Serial testing of hs-cTnT over 1 hour along with application of an m-HS identified a low-risk population that might be able to be directly discharged from the emergency department.
  •  
6.
  • McCord, James, et al. (författare)
  • Symptoms Predictive of Acute Myocardial Infarction in the Troponin Era : Analysis From the TRAPID-AMI Study.
  • 2019
  • Ingår i: Critical Pathways in Cardiology. - 1535-282X .- 1535-2811. ; 18:1, s. 10-15
  • Tidskriftsartikel (refereegranskat)abstract
    • The TRAPID-AMI (High Sensitivity Cardiac Troponin T assay for rapid Rule-out of Acute Myocardial Infarction) study evaluated a rapid "rule-out" acute myocardial infarction (AMI). We evaluated what symptoms were associated with AMI as part of a substudy of TRAPID-AMI. There were 1282 patients evaluated from 12 centers in Europe, the United States of America, and Australia from 2011 to 2013. Multiple symptom variables were prospectively obtained and evaluated for association with the final diagnosis of AMI. Multivariate logistic regression analysis was done, and odds ratios (OR) were calculated. There were 213/1282 (17%) AMIs. Four independent predictors for the diagnosis of AMI were identified: radiation to right arm or shoulder [OR = 3.0; confidence interval (CI): 1.8-5.0], chest pressure (OR = 2.5; CI: 1.3-4.6), worsened by physical activity (OR = 1.7; CI: 1.2-2.5), and radiation to left arm or shoulder (OR = 1.7; CI: 1.1-2.4). In the entire group, 131 (10%) had radiation to right arm or shoulder, 897 (70%) had chest pressure, 385 (30%) worsened with physical activity, and 448 (35%) had radiation to left arm or shoulder. Duration of symptoms was not predictive of AMI. There were no symptoms predictive of non-AMI. Relationship between AMI size and symptoms was also studied. For 213 AMI patients, cardiac troponins I values were divided into 4 quartiles. Symptoms including pulling chest pain, supramammillary right location, and right arm/shoulder radiation were significantly more likely to occur in patients with larger AMIs. In a large multicenter trial, only 4 symptoms were associated with the diagnosis of AMI, and no symptoms that were associated with a non-AMI diagnosis.
  •  
7.
  • Mueller, Christian, et al. (författare)
  • Multicenter Evaluation of a 0-Hour/1-Hour Algorithm in the Diagnosis of Myocardial Infarction With High-Sensitivity Cardiac Troponin T
  • 2016
  • Ingår i: Annals of Emergency Medicine. - : Elsevier BV. - 0196-0644 .- 1097-6760. ; 68:1, s. 76-87
  • Tidskriftsartikel (refereegranskat)abstract
    • Study objective: We aim to prospectively validate the diagnostic accuracy of the recently developed 0-h/1-h algorithm, using high-sensitivity cardiac troponin T (hs-cTnT) for the early rule-out and rule-in of acute myocardial infarction. Methods: We enrolled patients presenting with suspected acute myocardial infarction and recent (<6 hours) onset of symptoms to the emergency department in a global multicenter diagnostic study. Hs-cTnT (Roche Diagnostics) and sensitive cardiac troponin I (Siemens Healthcare) were measured at presentation and after 1 hour, 2 hours, and 4 to 14 hours in a central laboratory. Patient triage according to the predefined hs-cTnT 0-hour/1-hour algorithm (hs-cTnT beloow 12 ng/L and Delta 1 hour below 3 ng/L to rule out; hs-cTnT at least 52 ng/L r Delta 1 hour at least 5 ng/L to rule in; remaining patients to the "observational zone") was compared against a centrally adjudicated final diagnosis by 2 independent cardiologists (reference standard). The final diagnosis was based on all available information, including coronary angiography and echocardiography results, follow-up data, and serial measurements of sensitive cardiac troponin I, whereas adjudicators remained blinded to hs-cTnT. Results: Among 1,282 patients enrolled, acute myocardial infarction was the final diagnosis for 213 (16.6%) patients. Applying the hs-cTnT 0-hour/1-hour algorithm, 813 (63.4%) patients were classified as rule out, 184 (14.4%) were classified as rule in, and 285 (22.2%) were triaged to the observational zone. This resulted in a negative predictive value and sensitivity for acute myocardial infarction of 99.1% (95% confidence interval [CI] 98.2% to 99.7%) and 96.7% (95% CI 93.4% to 98.7%) in the rule-out zone (7 patients with false-negative results), a positive predictive value and specificity for acute myocardial infarction of 77.2% (95% CI 70.4% to 83.0%) and 96.1% (95% CI 94.7% to 97.2%) in the rule-in zone, and a prevalence of acute myocardial infarction of 22.5% in the observational zone. Conclusion: The hs-cTnT 0-hour/1-hour algorithm performs well for early rule-out and rule-in of acute myocardial infarction.
  •  
8.
  •  
9.
  • Mueller, Christian, et al. (författare)
  • Use of copeptin for rapid rule-out of acute myocardial infarction
  • 2018
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 2048-8726 .- 2048-8734. ; 7:6, s. 570-576
  • Tidskriftsartikel (refereegranskat)abstract
    • Copeptin is currently understood as a quantitative marker of endogenous stress. It rises rapidly in multiple acute disorders including acute myocardial infarction. As a single variable, it has only modest diagnostic accuracy for acute myocardial infarction. However, the use of copeptin within a dual-marker strategy together with conventional cardiac troponin increases the diagnostic accuracy and particularly the negative predictive value of cardiac troponin alone for acute myocardial infarction. The rapid rule-out of acute myocardial infarction is the only application in acute cardiac care mature enough to merit consideration for routine clinical care. However, the dual-marker approach seems to provide only very small incremental value when used in combination with sensitive or high-sensitivity cardiac troponin assays. This review aims to update and educate regarding the potential and the procedural details, as well as the caveats and challenges of using copeptin in clinical practice.
  •  
10.
  • Mueller-Hennessen, Matthias, et al. (författare)
  • Combined testing of copeptin and high-sensitivity cardiac troponin T at presentation in comparison to other algorithms for rapid rule-out of acute myocardial infarction
  • 2019
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273 .- 1874-1754. ; 276, s. 261-267
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: We aimed to directly compare the diagnostic and prognostic performance of a dual maker strategy (DMS) with combined testing of copeptin and high-sensitivity (hs) cardiac troponin T (cTnT) at time of presentation with other algorithms for rapid rule-out of acute myocardial infarction (AMI).METHODS: 922 patients presenting to the emergency department with suspected AMI and available baseline copeptin measurements qualified for the present TRAPID-AMI substudy. Diagnostic measures using the DMS (copeptin <10, <14 or < 20 pmol/L and hs-cTnT≤14 ng/L), the 1 h-algorithm (hs-cTnT<12 ng/L and change <3 ng/L at 1 h), as well as the hs-cTnT limit-of-blank (LoB, <3 ng/L) and -detection (LoD, <5 ng/L) were compared. Outcomes were assessed as combined end-points of death and myocardial re-infarction.RESULTS: True-negative rule-out using the DMS could be achieved in 50.9%-62.3% of all patients compared to 35.0%, 45.3% and 64.5% using LoB, LoD or the 1 h-algorithm, respectively. The DMS showed NPVs of 98.1%-98.3% compared to 99.2% for the 1 h-algorithm, 99.4% for the LoB and 99.3% for the LoD. Sensitivities were 93.5%-94.8%, as well as 96.8%, 98.7% and 98.1%, respectively. Addition of clinical low-risk criteria such as a HEART-score ≤ 3 to the DMS resulted in NPVs and sensitivities of 100% with a true-negative rule-out to 33.8%-41.6%. Rates of the combined end-point of death/MI within 30 days ranged between 0.2% and 0.3% for all fast-rule-out protocols.CONCLUSION: Depending on the applied copeptin cut-off and addition of clinical low-risk criteria, the DMS might be an alternative to the hs-cTn-only-based algorithms for rapid AMI rule-out with comparable diagnostic measures and outcomes.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy