SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lindholm Carita) "

Sökning: WFRF:(Lindholm Carita)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ainsbury, Elizabeth A., et al. (författare)
  • Inter- and intra-laboratory comparison of a multibiodosimetric approach to triage in a simulated, large scale radiation emergency
  • 2014
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 90:2, s. 193-202
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The European Union's Seventh Framework Programme-funded project 'Multi-disciplinary biodosimetric tools to manage high scale radiological casualties' (MULTIBIODOSE) has developed a multiparametric approach to radiation biodosimetry, with a particular emphasis on triage of large numbers of potentially exposed individuals following accidental exposures. In November 2012, an emergency exercise took place which tested the capabilities of the MULTIBIODOSE project partners. The exercise described here had a dual purpose: Intercomparison of (i) three biodosimetric assays, and (ii) the capabilities of the seven laboratories, with regards to provision of triage status for suspected radiation exposed individuals. Materials and methods: Three biological dosimetry tools - the dicentric, micronucleus and gamma-H2AX (the phosphorylated form of member X of histone H2A, in response to DNA double-strand breaks) foci assays - were tested, in addition to provision of the triage status results (low exposure: <1 Gy; medium exposure: 1-2 Gy; high exposure: >2 Gy) by the MULTIBIODOSE software. The exercise was run in two modes: An initial triage categorisation of samples (based on the first dose estimates for each assay received from each laboratory) followed by collation of the full set of estimated doses (all the results from all modes of each assay carried out by the participating laboratories) calculated using as many modes of operation as possible of the different assays developed during the project. Simulated acute whole body and partial body exposures were included. Results: The results of the initial triage categorisation and the full comparison of assays and methods within and between laboratories are presented here. Conclusions: The data demonstrate that the MULTIBIODOSE approach of applying multiparametric tools to radiation emergencies is valid and effective.
  •  
2.
  • Ainsbury, Elizabeth A., et al. (författare)
  • MULTIBIODOSE RADIATION EMERGENCY TRIAGE CATEGORIZATION SOFTWARE
  • 2014
  • Ingår i: Health Physics. - 0017-9078 .- 1538-5159. ; 107:1, s. 83-89
  • Tidskriftsartikel (refereegranskat)abstract
    • In this note, the authors describe the MULTIBIODOSE software, which has been created as part of the MULTIBIODOSE project. The software enables doses estimated by networks of laboratories, using up to five retrospective (biological and physical) assays, to be combined to give a single estimate of triage category for each individual potentially exposed to ionizing radiation in a large scale radiation accident or incident. The MULTIBIODOSE software has been created in Java. The usage of the software is based on the MULTIBIODOSE Guidance: the program creates a link to a single SQLite database for each incident, and the database is administered by the lead laboratory. The software has been tested with Java runtime environment 6 and 7 on a number of different Windows, Mac, and Linux systems, using data from a recent intercomparison exercise. The Java program MULTIBIODOSE_1.0.jar is freely available to download from http://www.multibiodose.eu/software or by contacting the software administrator: MULTIBIODOSE-software@gmx.com.
  •  
3.
  • Francesc Barquinero, Joan, et al. (författare)
  • RENEB biodosimetry intercomparison analyzing translocations by FISH
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 30-35
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: In the framework of RENEB, several biodosimetry exercises were conducted analyzing different endpoints. Among them, the analysis of translocations is considered the most useful method for retrospective biodosimetry due to the relative stability of their frequency with post irradiation time. The aim of this study was to harmonize the accuracy of translocation-based biodosimetry within the RENEB consortium. Materials and methods: An initial telescoring exercise analyzing FISH metaphase images was done to harmonize chromosome aberration descriptions. Then two blind intercomparison exercises (IE) were performed, by sending irradiated blood samples to each partner. Samples were cultured and stained by each partner using their standard protocol and translocation frequency was used to produce dose estimates. Results: The coefficient of variation in the 1st IE (CV = 0.34) was higher than in the 2nd IE (CV = 0.16 and 0.23 in the two samples analyzed), for the genomic frequency of total translocations. Z-score analysis revealed that eight out of 10 and 17 out of 20 dose estimates were satisfactory in the 1st and 2nd IE, respectively. Conclusions: The results obtained indicate that, despite the problems identified in few partners, which can be corrected, the RENEB consortium is able to carry out retrospective biodosimetry analyzing the frequency of translocations by FISH.
  •  
4.
  •  
5.
  • Jaworska, Alicja, et al. (författare)
  • Operational guidance for radiation emergency response organisations in Europe for using biodosimetric tools developed in EU MULTIBIODOSE project
  • 2015
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 164:1-2, s. 165-169
  • Tidskriftsartikel (refereegranskat)abstract
    • In the event of a large-scale radiological emergency, the triage of individuals according to their degree of exposure forms an important initial step of the accident management. Although clinical signs and symptoms of a serious exposure may be used for radiological triage, they are not necessarily radiation specific and can lead to a false diagnosis. Biodosimetry is a method based on the analysis of radiation-induced changes in cells of the human body or in portable electronic devices and enables the unequivocal identification of exposed people who should receive medical treatment. The MULTIBIODOSE (MBD) consortium developed and validated several biodosimetric assays and adapted and tested them as tools for biological dose assessment in a mass-casualty event. Different biodosimetric assays were validated against the 'gold standard' of biological dosimetry-the dicentric assay. The assays were harmonised in such a way that, in an emergency situation, they can be run in parallel in a network of European laboratories. The aim of this guidance is to give a concise overview of the developed biodosimetric tools as well as how and when they can be used in an emergency situation.
  •  
6.
  • Kiuru, Anne, et al. (författare)
  • XRCC1 and XRCC3 variants and risk of glioma and meningioma
  • 2008
  • Ingår i: Journal of Neuro-Oncology. - : Springer. - 0167-594X .- 1573-7373. ; 88, s. 135-142
  • Tidskriftsartikel (refereegranskat)abstract
    • Several single nucleotide polymorphisms (SNPs) affecting DNA repair capacity and modifying cancer susceptibility have been described. We evaluated the association of SNPs Arg194Trp, Arg280His, and Arg399Gln in the X-ray cross-complementing group 1 (XRCC1) and Thr241Met in the X-ray cross-complementing group 3 (XRCC3) DNA repair genes with the risk of brain tumors. The Caucasian study population consisted of 701 glioma (including 320 glioblastoma) cases, 524 meningioma cases, and 1,560 controls in a prospective population-based case-control study conducted in Denmark, Finland, Sweden, and the UK. The studied SNPs were not significantly associated with the risk of brain tumors. The highest odds ratios (ORs) for the associations were observed between the homozygous variant genotype XRCC1 Gln399Gln and the risk of glioma (OR = 1.32; 95% confidence interval, CI, 0.97-1.81), glioblastoma (OR = 1.48; 95% CI, 0.98-2.24), and meningioma (OR = 1.34; 95% CI, 0.96-1.86). However, in pair-wise comparisons a few SNP combinations were associated with the risk of brain tumors: Among others, carriers of both homozygous variant genotypes, i.e., XRCC1 Gln399Gln and XRCC3 Met241Met, were associated with a three-fold increased risk of glioma (OR = 3.18; 95% CI, 1.26-8.04) and meningioma (OR = 2.99; 95% CI, 1.16-7.72). In conclusion, no significant association with brain tumors was found for any of the polymorphisms, when examined one by one. Our results indicated possible associations between combinations of XRCC1 and XRCC3 SNPs and the risk of brain tumors.
  •  
7.
  • Kulka, Ulrike, et al. (författare)
  • RENEB - Running the European Network of biological dosimetry and physical retrospective dosimetry
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 2-14
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. Results: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. Conclusions: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.
  •  
8.
  • Lindholm, Carita, et al. (författare)
  • Premature chromosome condensation (PCC) assay for dose assessment in mass casualty accidents
  • 2010
  • Ingår i: Radiation Research. - 0033-7587 .- 1938-5404. ; 173:1, s. 71-8
  • Tidskriftsartikel (refereegranskat)abstract
    • The study was undertaken to establish a dose calibration curve for a practical PCC ring assay and to apply it in a simulated mass casualty accident. The PCC assay was validated against the conventional dicentric assay. A linear relationship was established for PCC rings after (60)Co gamma irradiation with doses up to 20 Gy. In the simulated accident experiment, 62 blood samples were analyzed with both the PCC ring assay and the conventional dicentric assay, applying a triage approach. Samples received various uniform and non-uniform (10-40% partial-body) irradiations up to doses of 13 Gy. The results indicated that both assays yielded good dose estimates for the whole-body exposure scenario, although in the lower-dose range (0-6 Gy) dicentric scoring resulted in more accurate whole-body estimates, whereas PCC rings were better in the high-dose range (>6 Gy). Neither assay was successful in identifying partial-body exposures, most likely due to the low numbers of cells scored in the triage mode. In conclusion, the study confirmed that the PCC ring assay is suitable for use as a biodosimeter after whole-body exposure to high doses of radiation. However, there are limitations for its use in the triage of people exposed to high, partial-body doses.
  •  
9.
  • Oestreicher, Ursula, et al. (författare)
  • RENEB intercomparisons applying the conventional Dicentric Chromosome Assay (DCA)
  • 2017
  • Ingår i: International Journal of Radiation Biology. - : Informa UK Limited. - 0955-3002 .- 1362-3095. ; 93:1, s. 20-29
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. Materials and methods: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. Results: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. Conclusions: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.
  •  
10.
  • Pernot, Eileen, et al. (författare)
  • Ionizing radiation biomarkers for potential use in epidemiological studies
  • 2012
  • Ingår i: Mutation Research. - : Elsevier BV. - 1383-5742 .- 1388-2139. ; 751:2, s. 258-286
  • Forskningsöversikt (refereegranskat)abstract
    • Ionizing radiation is a known human carcinogen that can induce a variety of biological effects depending on the physical nature, duration, doses and dose-rates of exposure. However, the magnitude of health risks at low doses and dose-rates (below 100 mSv and/or 0.1 mSv min(-1)) remains controversial due to a lack of direct human evidence. It is anticipated that significant insights will emerge from the integration of epidemiological and biological research, made possible by molecular epidemiology studies incorporating biomarkers and bioassays. A number of these have been used to investigate exposure, effects and susceptibility to ionizing radiation, albeit often at higher doses and dose rates, with each reflecting time-limited cellular or physiological alterations. This review summarises the multidisciplinary work undertaken in the framework of the European project DoReMi (Low Dose Research towards Multidisciplinary Integration) to identify the most appropriate biomarkers for use in population studies. In addition to logistical and ethical considerations for conducting large-scale epidemiological studies, we discuss the relevance of their use for assessing the effects of low dose ionizing radiation exposure at the cellular and physiological level. We also propose a temporal classification of biomarkers that may be relevant for molecular epidemiology studies which need to take into account the time elapsed since exposure. Finally, the integration of biology with epidemiology requires careful planning and enhanced discussions between the epidemiology, biology and dosimetry communities in order to determine the most important questions to be addressed in light of pragmatic considerations including the appropriate population to be investigated (occupationally, environmentally or medically exposed), and study design. The consideration of the logistics of biological sample collection, processing and storing and the choice of biomarker or bioassay, as well as awareness of potential confounding factors, are also essential.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12
Typ av publikation
tidskriftsartikel (11)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (12)
Författare/redaktör
Lindholm, Carita (11)
Wójcik, Andrzej (8)
Gregoire, Eric (6)
Oestreicher, Ursula (6)
Romm, Horst (6)
Beinke, Christina (5)
visa fler...
Moquet, Jayne (5)
Rothkamm, Kai (5)
Sommer, Sylwester (5)
Ainsbury, Elizabeth ... (4)
Jaworska, Alicja (4)
Thierens, Hubert (4)
Vral, Anne (4)
Lloyd, David (3)
Fattibene, Paola (3)
Woda, Clemens (3)
Francesc Barquinero, ... (3)
Terzoudi, Georgia (3)
Hadjidekova, Valeria (3)
Barnard, Stephen (2)
de Gelder, Virginie (2)
Scherthan, Harry (2)
Vandevoorde, Charlot (2)
Barrios, Lleonard (2)
Roy, Laurence (2)
Trompier, Francois (2)
Ainsbury, Elizabeth (2)
Dominguez, Inmaculad ... (2)
Johansen, Christoffe ... (1)
Feychting, Maria (1)
Hagmar, Lars (1)
Strömberg, Ulf (1)
Norppa, Hannu (1)
Al-hafidh, Jenna (1)
Bajinskis, Ainars (1)
Barquinero, Joan Fra ... (1)
Nylund, Reetta (1)
Roch-Lefevre, Sandri ... (1)
Nergaard, Inger (1)
Samaga, Daniel (1)
Della Monaca, Sara (1)
Guclu, Inci (1)
Badie, Christophe (1)
Abend, Michael (1)
Antunes, Ana Catarin ... (1)
Bortolin, Emanuela (1)
Buraczewska, Iwona (1)
Filippi, Silvia (1)
Guogyte, Kamile (1)
Hristova, Rositsa (1)
visa färre...
Lärosäte
Stockholms universitet (9)
Umeå universitet (1)
Uppsala universitet (1)
Lunds universitet (1)
Karolinska Institutet (1)
Språk
Engelska (11)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (8)
Medicin och hälsovetenskap (7)
Teknik (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy