SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ljunggren Kaj) ;pers:(Börjesson Siv)"

Sökning: WFRF:(Ljunggren Kaj) > Börjesson Siv

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Risberg, Jarl, et al. (författare)
  • A new tomographic technique for absolute measurements of white and gray matter blood flow
  • 2004
  • Ingår i: Proceedings of the 8th Nordic Meeting in Neuropsychology, Turku, Finland, August 26–29, 2004, 85.
  • Konferensbidrag (refereegranskat)abstract
    • Objective. Most methods for measurements of the regional cerebral blood flow are unable to provide absolute blood flow values. Until now interest has been focused on measurement of the gray matter blood flow, while the white matter blood flow has been rather neglected. The aim of the present project was to develop and evaluate an improved method for reliable tomographic measurements of absolute white and gray matter blood flow Method. The new tomographic method (modified Xe-SPECT) is based on an extension of the period of 133Xe inhalation from one to eight minutes followed by 22 instead of four minutes of breathing of ambient air. This gives a markedly enhanced signal from the white matter and better basis for correct quantification of the blood flow. The arrival and clearance of the tracer are recorded by a three head gamma camera system that provides flow maps with a spatial resolution of about one cm. Results The new method has been evaluated in 33 healthy younger and older (around 70 years) subjects as well as in a group of elderly patients with organic dementia. Our preliminary findings indicate that new and clinically valuable information is obtained by the improved Xe-SPECT method.
  •  
2.
  • Risberg, Jarl, et al. (författare)
  • A new tomographic technique for absolute measurements of white and gray matter blood flow
  • 2003
  • Ingår i: Journal of the International Neuropsychological Society. - 1355-6177. ; 9, s. 323-323
  • Konferensbidrag (refereegranskat)abstract
    • The integrity of the white matter is as important as that of the gray matter and white matter pathology has commonly been reported in elderly subjects and in patients with organic dementia. The aim of the present study is to develop and evaluate an improved method for reliable tomographic measurements of absolute white and gray matter blood flow. The new tomographic method (modified Xe-SPECT) is based on an extension of the period of 133Xe inhalation from one to eight minutes followed by 22 instead of four minutes of breathing of ambient air. This gives a markedly enhanced signal from the white matter and better basis for correct quantification pf the blood flow. The arrival and clearance of the tracer are recorded by a three head gamma camera system that provides flow maps with a spatial resolution of about one cm. The new method has been evaluated in healthy younger and older (around 70 years) subjects as well as in a group of elderly patients with organic dementia. Our preliminary findings indicate that new and clinically valuable information is obtained by the improved Xe-SPECT method
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
konferensbidrag (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Risberg, Jarl (2)
Ljunggren, Kaj (2)
Gustafson, Lars (1)
Passant, Ulla (1)
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy