SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Ljunggren Kaj)
 

Sökning: WFRF:(Ljunggren Kaj) > Palmer John > Construction of a P...

Construction of a Pre-Clinical High Resolution Tomographic Scintillation Camera System

Peterson, Mikael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ljunggren, Kaj (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Palmer, John (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Strand, Sven-Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Miller, Brian (författare)
visa färre...
 (creator_code:org_t)
2009
2009
Engelska.
Ingår i: 2009 IEEE Nuclear Science Symposium Conference Record, Vols 1-5. - 1082-3654. ; , s. 3670-3671
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • We are constructing a High Resolution Tomographic Scintillation Camera System for small animal imaging. The system consists of a CsI(Tl) scintillator coupled to a military surplus image intensifier with a CCD camera focused on the output window. The system operates in photons counting mode and the spatial resolution is improved by centroid calculations for every photon interaction. The system can be mounted on an optical rail together with a pinhole collimator and a rotating table. A hot rod phantom was filled with Tl-201 or Tc-99m solute and imaged. The phantom rod diameters range from 1.1 to 1.6 mm. 64 projections were acquired (300 s/projection) with 1 mm pinhole insert. Data was reconstructed using an OSEM algorithm. Image data was corrected for decay, position non-linearities in image intensifier and the angular dependence of the pinhole. The reconstructed resolution is 13 mm (by visual inspection) for both Tc-99m and Tl-201. Higher spatial resolution is achievable with smaller pinhole diameters. Future work includes optimizing spatial resolution and sensitivity of a single system using analytical calculations, experiments and simulations. With the conclusions drawn from those calculations we plan to construct a multi-camera system.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

single photon imaging
component
small animal SPECT
molecular imaging

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Peterson, Mikael
Ljunggren, Kaj
Palmer, John
Strand, Sven-Eri ...
Miller, Brian
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
2009 IEEE Nuclea ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy