SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lund Jensen Bengt) ;pers:(Francke T.)"

Sökning: WFRF:(Lund Jensen Bengt) > Francke T.

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Carlson, P., et al. (författare)
  • Beyond the RICH : innovative photosensitive gaseous detectors for new fields of applications
  • 2003
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 502:1, s. 189-194
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (> 10(4)) can be achieved in a single multiplication step. This is possible by, for instance, exploiting the secondary electron multiplication and limiting the energy of the steamers by distributed resistivity. The single step approach also allows a very good position resolution to be achieved in some devices: 50 mum on line without applying any treatment method (like center of gravity). The main focus of our report is new fields of applications for these detectors and the optimization of their designs for such purposes.
  •  
2.
  • Carlson, P., et al. (författare)
  • Gaseous photomultipliers with solid photocathodes for the detection of sparks, flames and dangerous gases
  • 2003
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 505:02-jan, s. 207-210
  • Tidskriftsartikel (refereegranskat)abstract
    • In many applications, it is necessary to detect sparks or flames in daylight conditions or in illuminated areas. Most flames emit strongly in the ultraviolet spectrum (180-280 nm), and this property can be used for reliable identification of flames. We have developed new spark and flame detectors based on gaseous photomultipliers with CsI, CuI or CsTe photocathodes. A modified version of the detector can also detect smoke and dangerous vapors. These detectors are able to perform complex monitoring and detection functions. Some of their advantages are: low cost, high sensitivity, large output signal and operation under battery power. Gaseous photomultipliers can be position sensitive and, if necessary, be used in combination with various optical systems, for example for monitoring flames from space.
  •  
3.
  • Iacobaeus, C., et al. (författare)
  • A high position resolution X-ray detector : An Edge on illuminated capillary plate combined with a gas amplification structure
  • 2006
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 53:2, s. 554-561
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed and successfully tested a prototype of a new high position resolution hybrid X-ray detector. It contains a thin-wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche chamber operating in various gas mixtures at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0-90 degrees. The detection efficiency, depending on the geometry, photon's energy, incident angle and the mode of operation was between 5-30% in single step mode and up to 50% in a multi-layered combination. Depending on the capillary's geometry, the position resolution achieved was between 50-250 mu m in digital form and was practically independent of the photon's energy or gas mixture. The usual lead glass capillary plates operated without noticeable charging up effects at counting rates of 50 Hz/mm(2) and hydrogen treated capillaries-up to 10(5) Hz/mm(2). The developed detector has several important potential advantages over the exciting X-ray detectors and may open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), as well as many other applications.
  •  
4.
  • Iacobaeus, C., et al. (författare)
  • An X-ray scanner based on an "edge on" illuminated capillary plate combined with a gas amplification structure
  • 2004
  • Ingår i: 2004 IEEE Nuclear Science Symposium Conference Record. ; , s. 489-492
  • Konferensbidrag (refereegranskat)abstract
    • We have developed and successfully tested a prototype of a new type of high position resolution X-ray scanner. It contains a thin wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche chamber operating in various gas mixtures at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0-90°. The detection efficiency, depending on the geometry, photon's energy, incident angle and the mode of operation, was between 5-30% in a single step mode and up to 50% in a multi-layered combination. Depending on the capillary's geometry, the position resolution achieved was between 50-250 μm in digital form and was practically independent of the photon's energy or gas mixture. The usual lead glass capillary plates operated without noticeable charging up effects at counting rates of 50 Hz/mm2, and hydrogen treated capillaries up to 10 5 Hz/mm2. Finally, a prototype of the X-ray scanner based on an "edge-on" illumination capillary plate was built and tested. The developed detector open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), crystallography and many other applications.
  •  
5.
  • Iacobaeus, C., et al. (författare)
  • An X-ray scanner prototype based on a novel hybrid gaseous detector
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 573:02-jan, s. 61-64
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed a prototype of a new type of hybrid X-ray detector. It contains a thin wall (few mu m) edge-illuminated lead glass capillary plate (acting as a converter of X-rays photons to primary electrons) combined with a microgap parallel-plate avalanche chamber operating in various gas mixtures at 1 atm. The operation of these converters was studied in a wide range of X-ray energies (from 6 to 60 keV) at incident angles varying from 0 degrees to 90 degrees. The detection efficiency, depending on the geometry, photon's energy, incident angle and the mode of operation, was between a few and similar to 40%. The position resolution achieved was similar to 50 mu m in digital form and was practically independent of the photon's energy or gas mixture. The developed detector may open new possibilities for medical imaging, for example in mammography, portal imaging, radiography (including security devices), crystallography and many other applications.
  •  
6.
  • Periale, L., et al. (författare)
  • Successful operation of hole-type gaseous detectors at cryogenic temperatures
  • 2004
  • Ingår i: 2004 IEEE Nuclear Science Symposium Conference Record. - 0780387007 ; , s. 1147-1151
  • Konferensbidrag (refereegranskat)abstract
    • We have demonstrated that hole-type gaseous detectors, GEMs and capillary plates, can operate up to 77 K. For example, a single capillary plate can operate at gains of above 103 in the entire temperature interval between 300 until 77 K. The same capillary plate combined with Csi photocathodes could operate perfectly well at gains (depending on gas mixtures) of 100-1000. Obtained results may open new fields of applications for capillary plates as detectors of UV light and charge particles at cryogenic temperatures: noble liquid TPCs, WIMP detectors or LXe scintillating calorimeters and cryogenic PETs.
  •  
7.
  • Periale, L., et al. (författare)
  • The development of gaseous detectors with solid photocathodes for low-temperature applications
  • 2004
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - 0168-9002 .- 1872-9576. ; 535:02-jan, s. 517-522
  • Tidskriftsartikel (refereegranskat)abstract
    • There are several applications and studies in fundamental research, which require the detection of VUV light at cryogenic temperatures. For these applications, we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrated that both primary and secondary (due to the avalanche multiplication inside liquids) scintillation light can be recorded by photosensitive gaseous detectors. The results of this work may allow one to significantly improve the operation of some noble liquid TPCs.
  •  
8.
  • Periale, L., et al. (författare)
  • The successful operation of hole-type gaseous detectors at cryogenic temperatures
  • 2005
  • Ingår i: IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9499 .- 1558-1578. ; 52:4, s. 927-931
  • Tidskriftsartikel (refereegranskat)abstract
    • We have demonstrated that hole-type gaseous detectors, gas electron multipliers and capillary plates (CPs) can operate at temperatures down to 77 K. For example, a single CP can operate at gains above 10(3) in the entire temperature interval between 77 and 300 K. The same CP combined with CsI photocathodes operates perfectly well at gains of 100-1000, depending on the gas mixture. The obtained results open new fields of applications for CPs as detectors of ultraviolet light and charged particles at cryogenic temperatures: liquid noble gas time-projection chambers, detectors for weakly interacting massive particles or liquid Xe scintillating calorimeters, and cryogenic positron-emission tomography.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy