SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Extended search

WFRF:(Mahteme Haile)
 

Search: WFRF:(Mahteme Haile) > (2005-2009) > Anundi Helena > Peritonectomy with ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Peritonectomy with high voltage electrocautery generates higher levels of ultrafine smoke particles

Andréasson, Sara Näslund (author)
Uppsala universitet,Kolorektalkirurgi
Anundi, Helena (author)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
Sahlberg, Bo (author)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
show more...
Ericsson, Claes-Gunnar (author)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
Wålinder, Robert (author)
Uppsala universitet,Institutionen för medicinska vetenskaper,Eva Vingård
Enlund, G. (author)
Påhlman, Lars (author)
Uppsala universitet,Kolorektalkirurgi
Mahteme, Haile (author)
Uppsala universitet,Kolorektalkirurgi
show less...
 (creator_code:org_t)
Elsevier BV, 2008
2008
English.
In: European Journal of Surgical Oncology. - : Elsevier BV. - 0748-7983 .- 1532-2157. ; 35:7, s. 780-784
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: To adequately perform peritonectomy, the use of an electrocautery device at a high voltage is recommended. The aim of this study was to analyse the amount of airborne and ultrafine particles (UFP) generated during peritonectomy and to compare this with standard colon and rectal cancer surgery (CRC). METHOD: UFP was measured approximately 2-3cm from the breathing area of the surgeon (personal sampling) and 3m from where the electrocautery smoke was generated (stationary sampling) from 14 consecutive peritonectomy procedures and 11 standard CRC resections. The sampling was by P-Trak UFP counter that has the capacity to detect particle size ranging from 0.02 to 1mum. RESULTS: The cumulative level of UFP of personal sampling in the peritonectomy group was higher (9.3x10(6)particle/ml/h (pt/ml/h)) than in the control group (4.8x10(5)pt/ml/h). A higher cumulative level of UFP in stationary sampling was observed in the PC group (2.6x10(6) pt/ml/h) than in the control group (3.9x10(4)pt/ml/h). CONCLUSION: Peritonectomy procedure with high voltage electrocautery generates elevated levels of UFP than standard CRC surgery does. The level of UFP produced by a peritonectomy is comparable to cigarette smoking. More efficient smoke evacuator systems are needed in order to reduce the levels of UFP generated during electrocautery surgery.

Keyword

Peritonectomy
Peritoneal carcinomatosis
Ultrafine particles
Occupational
MEDICINE
MEDICIN

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view