SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Mathiassen Svend Erik)
 

Sökning: WFRF:(Mathiassen Svend Erik) > Örebro universitet > Reliability of near...

Reliability of near-infrared spectroscopy for measuring forearm and shoulder oxygenation in healthy males and females

Crenshaw, Albert G. (författare)
Högskolan i Gävle,CBF,Centrum för belastningsskadeforskning
Elcadi, Guilherme H., 1966- (författare)
Högskolan i Gävle,Umeå universitet,Rehabiliteringsmedicin,CBF,Centrum för belastningsskadeforskning
Hellström, Fredrik (författare)
Högskolan i Gävle,CBF,Centrum för belastningsskadeforskning
visa fler...
Mathiassen, Svend Erik (författare)
Högskolan i Gävle,CBF,Centrum för belastningsskadeforskning
visa färre...
 (creator_code:org_t)
2011-11-23
2012
Engelska.
Ingår i: European Journal of Applied Physiology. - : Springer. - 1439-6319 .- 1439-6327. ; 112:7, s. 2703-2715
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This study determined the day-to-day reliability of NIRS-derived oxygenation responses (a dagger StO(2)%) for isometric contractions and for cuff occlusion. Twenty-four subjects (12 males and 12 females) were tested for 2 days (4-6 days interval). Variables generated were: (1) a dagger StO(2)% for isometric contractions (10, 30, 50 and 70% MVC) for descending trapezius (TD) and extensor carpi radialis (ECR) muscles; (2) slope changes in total haemoglobin (HbTslope) and deoxyhaemoglobin (HHbslope) for the ECR using upper arm venous (VO, 50 mmHg) and arterial occlusion (AO, 250 mmHg); (3) recovery slopes (Rslope) for oxygen saturation (StO(2)) following isometric contractions and AO. For each variable, an intraclass correlation (ICC) was calculated to assess the ability to differentiate between subjects, and limits of agreement (LOA) were computed to assess day-to-day consistency of the measurement. ICCs for Delta StO(2)% were lowest at 10% MVC for both ECR (0.58) and TD (0.55), and highest at 30% MVC for ECR (0.95) and at 70% MVC for TD (0.79). For both muscles, LOA for Delta StO(2)% was lowest at 10% and highest at 50 and 70% MVC. ICC for HbTslope was 0.17. For HHbslope ICC was higher for AO (0.83) than for VO (0.73), and LOA was lower for AO. For the ECR Rslope ICCs ranged from 0.88 to 0.90 for contraction, but was lower for AO (0.33); LOA was lowest at 70% MVC. For trapezius Rslope ICCs ranged from 0.63 to 0.73 and LOA was lowest at 30% MVC. For this study, establishing reliability data for the ECR and TD and including variables commonly reported are expected to have meaning for future NIRS studies of work-related upper-extremity pain as well as for other NIRS research and clinical applications.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Nyckelord

Near-infrared spectroscopy
Intraclass correlation
Limits of agreement
Oxygenation saturation
Within-subject variability
Between-subject variability

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy