Evaluation of the corrosion risk of duplex stainless steel UNS S82551 in treated seawater injection service
-
- Nice, P. (författare)
- Statoil ASA, Norway
-
- Larche, Nicolas (författare)
- RISE,KIMAB,Institut de la Corrosion
-
- Amaya, H. (författare)
- Nippon Steel and Sumitomo Metal Corporation, Japan
-
visa fler...
-
- Matsuda, Y. (författare)
- Nippon Steel and Sumitomo Metal Corporation, Japan
-
- Scoppio, L. (författare)
- Pipe Team Srl, Italy
-
- Fiocchi, M. (författare)
- S and L Consulting, Switzerland
-
visa färre...
-
(creator_code:org_t)
- National Assoc. of Corrosion Engineers International, 2017
- 2017
- Engelska.
-
Ingår i: NACE - Int. Corros. Conf. Ser.. - : National Assoc. of Corrosion Engineers International. - 9781510840348 ; , s. 1225-1239
- Relaterad länk:
-
https://urn.kb.se/re...
Abstract
Ämnesord
Stäng
- In seawater handling systems, the available well tubing materials are Glass Reinforced Epoxy lined low alloy steel or Corrosion Resistant Alloy's (CRA) such as super duplex stainless steel. However, in treated seawater the corrosion risk can be controlled so that lower grade alloys can be considered. Recent efforts have focused attention on better dissolved oxygen controls which permits the investigation and possible use of more cost effective materials such as the duplex stainless steel UNS S82551. Full scale corrosion testing of tubes joined together with a proprietary premium threaded connection was performed in controlled seawater loops simulating service conditions at 30° C. The flow rate and dissolved oxygen were controlled at 5 m/s and <20ppb, respectively. Weekly dissolved oxygen excursions corresponding to 24h at 100ppb followed by 1 hour at 300ppb were included during the 5 months exposure. Corrosion results of UNS S82551 tubing were compared to UNS S31803 and UNS S39274. In parallel, laboratory exposures of coupons were performed in dissolved oxygen controlled cells with and without CREVCORR crevice formers, allowing the measurement of electrochemical potentials as function of dissolved oxygen content (e. g. biofilm ennoblement monitoring) and the related corrosion resistance. The results showed that dissolved oxygen content should be properly controlled below critical values to avoid crevice corrosion of the lesser alloyed duplex stainless steels. In the full scale loop test, UNS S82551 tubes did not exhibit crevice corrosion at threaded connection interfaces under the defined test conditions.
Nyckelord
- Crevice corrosion
- Dissolved oxygen
- Duplex stainless steels
- Treated seawater
- Alloy steel
- Corrosion
- Corrosion resistance
- Corrosion resistant alloys
- Cost effectiveness
- Dissolution
- Electrochemical corrosion
- High strength steel
- Materials handling
- Oxygen
- Seawater
- Stainless steel
- Tubing
- Dissolved oxygen contents
- Dissolved oxygen control
- Duplex stainless steel
- Electrochemical potential
- Service conditions
- Super duplex stainless steel
- Threaded connection