SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Mauri Francesco)
 

Sökning: WFRF:(Mauri Francesco) > Hall Wilton Richard > Fast neutron sensit...

Fast neutron sensitivity of neutron detectors based on Boron-10 converter layers

Mauri, G. (författare)
European Spallat Source ERIC Lund; Univ Perugia, Dept Phys, Perugia, Italy,University of Perugia,European Spallation Source ESS AB
Messi, Francesco (författare)
Lund University,Lunds universitet,Kärnfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,European Spallation Source ESS AB,Stiftelser och övriga anknutna verksamheter,Nuclear physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH,Other Institutions and Utilities
Kanaki, Kalliopi (författare)
European Spallat Source ERIC Lund,European Spallation Source ESS AB
visa fler...
Hall-Wilton, Richard (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion,European Spallat Source ERIC Lund
Karnickis, E. (författare)
European Spallat Source ERIC Lund,European Spallation Source ESS AB
Khaplanov, Anton (författare)
European Spallat Source ERIC Lund,European Spallation Source ESS AB
Piscitelli, Francesco (författare)
Lund University,Lunds universitet,European Spallation Source ESS AB,Stiftelser och övriga anknutna verksamheter,Other Institutions and Utilities
visa färre...
 (creator_code:org_t)
2018
2018
Engelska.
Ingår i: Journal of Instrumentation. - 1748-0221. ; 13:3
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In the last few years many detector technologies for thermal neutron detection have been developed in order to face the shortage of He-3, which is now much less available and more expensive. Moreover the He-3-based detectors can not fulfil the requirements in performance, e.g. the spatial resolution and the counting rate capability needed for the new instruments. The Boron-10-based gaseous detectors have been proposed as a suitable choice. This and other alternative technologies are being developed at ESS. Higher intensities mean higher signals but higher background as well. The signal-to-background ratio is an important feature to study, in particular the gamma-ray and the fast neutron contributions. This paper investigates, for the first time, the fast neutrons sensitivity of B-10-based thermal neutron detector. It presents the study of the detector response as a function of energy threshold and the underlying physical mechanisms. The latter are explained with the help of theoretical considerations and simulations.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)
NATURVETENSKAP  -- Fysik -- Subatomär fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Subatomic Physics (hsv//eng)

Nyckelord

Gaseous detectors
Neutron detectors (cold
thermal
fast neutrons)
Wire chambers (MWPC
Thin-gap chambers
drift chambers
drift tubes
proportional chambers etc)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy