SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Musy M.) "

Search: WFRF:(Musy M.)

  • Result 1-5 of 5
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Schael, S., et al. (author)
  • Electroweak measurements in electron positron collisions at W-boson-pair energies at LEP
  • 2013
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 532:4, s. 119-244
  • Research review (peer-reviewed)abstract
    • Electroweak measurements performed with data taken at the electron positron collider LEP at CERN from 1995 to 2000 are reported. The combined data set considered in this report corresponds to a total luminosity of about 3 fb(-1) collected by the four LEP experiments ALEPH, DELPHI, 13 and OPAL, at centre-of-mass energies ranging from 130 GeV to 209 GeV. Combining the published results of the four LEP experiments, the measurements include total and differential cross-sections in photon-pair, fermion-pair and four-fermion production, the latter resulting from both double-resonant WW and ZZ production as well as singly resonant production. Total and differential cross-sections are measured precisely, providing a stringent test of the Standard Model at centre-of-mass energies never explored before in electron positron collisions. Final-state interaction effects in four-fermion production, such as those arising from colour reconnection and Bose Einstein correlations between the two W decay systems arising in WW production, are searched for and upper limits on the strength of possible effects are obtained. The data are used to determine fundamental properties of the W boson and the electroweak theory. Among others, the mass and width of the W boson, m(w) and Gamma(w), the branching fraction of W decays to hadrons, B(W -> had), and the trilinear gauge-boson self-couplings g(1)(Z), K-gamma and lambda(gamma), are determined to be: m(w) = 80.376 +/- 0.033 GeV Gamma(w) = 2.195 +/- 0.083 GeV B(W -> had) = 67.41 +/- 0.27% g(1)(Z) = 0.984(-0.020)(+0.018) K-gamma - 0.982 +/- 0.042 lambda(gamma) = 0.022 +/- 0.019. (C) 2013 Elsevier B.V. All rights reserved.
  •  
2.
  • Schael, S, et al. (author)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • In: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Research review (peer-reviewed)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
3.
  • Dillner, Pernilla, et al. (author)
  • Incidence and characteristics of adverse events in paediatric inpatient care : a systematic review and meta-analysis
  • 2023
  • In: BMJ Quality and Safety. - : BMJ. - 2044-5415 .- 2044-5423. ; :3, s. 133-149
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Adverse events (AEs) cause suffering for hospitalised children, a fragile patient group where the delivery of adequate timely care is of great importance.OBJECTIVE: To report the incidence and characteristics of AEs, in paediatric inpatient care, as detected with the Global Trigger Tool (GTT), the Trigger Tool (TT) or the Harvard Medical Practice Study (HMPS) method.METHOD: MEDLINE, Embase, Web of Science and Google Scholar were searched from inception to June 2021, without language restrictions. Studies using manual record review were included if paediatric data were reported separately. We excluded studies reporting: AEs for a specific disease/diagnosis/treatment/procedure, or deceased patients; study protocols with no AE outcomes; conference abstracts, editorials and systematic reviews; clinical incident reports as the primary data source; and studies focusing on specific AEs only. Methodological risk of bias was assessed using a tool based on the Quality Assessment Tool for Diagnostic Accuracy Studies 2. Primary outcome was the percentage of admissions with ≥1 AEs. All statistical analyses were stratified by record review methodology (GTT/TT or HMPS) and by type of population. Meta-analyses, applying random-effects models, were carried out. The variability of the pooled estimates was characterised by 95% prediction intervals (PIs).RESULTS: We included 32 studies from 44 publications, conducted in 15 countries totalling 33 873 paediatric admissions. The total number of AEs identified was 8577. The most common types of AEs were nosocomial infections (range, 6.8%-59.6%) for the general care population and pulmonary-related (10.5%-36.7%) for intensive care. The reported incidence rates were highly heterogeneous. The PIs for the primary outcome were 3.8%-53.8% and 6.9%-91.6% for GTT/TT studies (general and intensive care population). The equivalent PI was 0.3%-33.7% for HMPS studies (general care). The PIs for preventable AEs were 7.4%-96.2% and 4.5%-98.9% for GTT/TT studies (general and intensive care population) and 10.4%-91.8% for HMPS studies (general care). The quality assessment indicated several methodological concerns regarding the included studies.CONCLUSION: The reported incidence of AEs is highly variable in paediatric inpatient care research, and it is not possible to estimate a reliable single rate. Poor reporting standards and methodological differences hinder the comparison of study results.
  •  
4.
  • Eggenschwiler, Luisa C, et al. (author)
  • Variation in detected adverse events using trigger tools : A systematic review and meta-analysis
  • 2022
  • In: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 17:9
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Adverse event (AE) detection is a major patient safety priority. However, despite extensive research on AEs, reported incidence rates vary widely.OBJECTIVE: This study aimed: (1) to synthesize available evidence on AE incidence in acute care inpatient settings using Trigger Tool methodology; and (2) to explore whether study characteristics and study quality explain variations in reported AE incidence.DESIGN: Systematic review and meta-analysis.METHODS: To identify relevant studies, we queried PubMed, EMBASE, CINAHL, Cochrane Library and three journals in the patient safety field (last update search 25.05.2022). Eligible publications fulfilled the following criteria: adult inpatient samples; acute care hospital settings; Trigger Tool methodology; focus on specialty of internal medicine, surgery or oncology; published in English, French, German, Italian or Spanish. Systematic reviews and studies addressing adverse drug events or exclusively deceased patients were excluded. Risk of bias was assessed using an adapted version of the Quality Assessment Tool for Diagnostic Accuracy Studies 2. Our main outcome of interest was AEs per 100 admissions. We assessed nine study characteristics plus study quality as potential sources of variation using random regression models. We received no funding and did not register this review.RESULTS: Screening 6,685 publications yielded 54 eligible studies covering 194,470 admissions. The cumulative AE incidence was 30.0 per 100 admissions (95% CI 23.9-37.5; I2 = 99.7%) and between study heterogeneity was high with a prediction interval of 5.4-164.7. Overall studies' risk of bias and applicability-related concerns were rated as low. Eight out of nine methodological study characteristics did explain some variation of reported AE rates, such as patient age and type of hospital. Also, study quality did explain variation.CONCLUSION: Estimates of AE studies using trigger tool methodology vary while explaining variation is seriously hampered by the low standards of reporting such as the timeframe of AE detection. Specific reporting guidelines for studies using retrospective medical record review methodology are necessary to strengthen the current evidence base and to help explain between study variation.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-5 of 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view