SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Notholt J.) ;mspu:(article);pers:(Toon G.)"

Sökning: WFRF:(Notholt J.) > Tidskriftsartikel > Toon G.

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hopfner, M., et al. (författare)
  • Validation of MIPAS ClONO2 measurements
  • 2007
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 7, s. 257-281
  • Tidskriftsartikel (refereegranskat)abstract
    • Altitude profiles of ClONO2 retrieved with the IMK (Institut fur Meteorologie und Klimaforschung) science-oriented data processor from MIPAS/Envisat (Michelson Interferometer for Passive Atmospheric Sounding on Envisat) mid-infrared limb emission measurements between July 2002 and March 2004 have been validated by comparison with balloon-borne (Mark IV, FIRS2, MIPAS-B), airborne (MIPAS-STR), ground-based (Spitsbergen, Thule, Kiruna, Harestua, Jungfraujoch, Izana, Wollongong, Lauder), and spaceborne (ACE-FTS) observations. With few exceptions we found very good agreement between these instruments and MIPAS with no evidence for any bias in most cases and altitude regions. For balloon-borne measurements typical absolute mean differences are below 0.05 ppbv over the whole altitude range from 10 to 39 km. In case of ACE-FTS observations mean differences are below 0.03 ppbv for observations below 26 km. Above this altitude the comparison with ACE-FTS is affected by the photochemically induced diurnal variation of ClONO2. Correction for this by use of a chemical transport model led to an overcompensation of the photochemical effect by up to 0.1 ppbv at altitudes of 30-35 km in case of MIPAS-ACE-FTS comparisons while for the balloon-borne observations no such inconsistency has been detected. The comparison of MIPAS derived total column amounts with ground-based observations revealed no significant bias in the MIPAS data. Mean differences between MIPAS and FTIR column abundances are 0.11 +/- 0.12 x 10(14) cm(-2) (1.0 +/- 1.1%) and -0.09 +/- 0.19 x 10(14) cm(-2) (-0.8 +/- 1.7%), depending on the coincidence criterion applied. chi(2) tests have been performed to assess the combined precision estimates of MIPAS and the related instruments. When no exact coincidences were available as in case of MIPAS-FTIR or MIPAS-ACE-FTS comparisons it has been necessary to take into consideration a coincidence error term to account for chi(2) deviations. From the resulting chi(2) profiles there is no evidence for a systematic over/underestimation of the MIPAS random error analysis.
  •  
2.
  • Kleinböhl, A., et al. (författare)
  • Constraints for the photolysis rate and the equilibrium constant of ClO-dimer from airborne and balloon-borne measurements of chlorine compounds
  • 2014
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 119:11, s. 6916--6937-6937
  • Tidskriftsartikel (refereegranskat)abstract
    • We analyze measurements of ClO across the terminator taken by the Airborne Submillimeter Radiometer (ASUR) in the activated vortices of the Arctic winters of 1995/1996, 1996/1997, and 1999/2000 to evaluate the plausibility of various determinations of the ClO-dimer photolysis cross section and the rate constant controlling the thermal equilibrium between ClO-dimer and ClO. We use measured ClO during sunlit conditions to estimate total active chlorine (ClOx). As the measurements suggest nearly full chlorine activation in winter 1999/2000, we compare ClOx estimates based on various photolysis frequencies of ClO-dimer with total available inorganic chlorine (Cly), estimated from an N2O-Cly correlation established by a balloon-borne MkIV interferometer measurement. Only ClO-dimer cross sections leading to the fastest photolysis frequencies in the literature (including the latest evaluation by the Jet Propulsion Laboratory) give ClOx mixing ratios that overlap with the estimated range of available Cly. Slower photolysis rates lead to ClOx values that are higher than available Cly. We use the ClOx calculated from sunlit ClO measurements to estimate ClO in darkness based on different equilibrium constants, and compare it with ASUR ClO measurements before sunrise at high solar zenith angles. Calculations with equilibrium constants published in recent evaluations of the Jet Propulsion Laboratory give good agreement with observed ClO mixing ratios. Equilibrium constants leading to a higher ClO/ClOx ratio in darkness yield ClO values that tend to exceed observed abundances. Perturbing the rates for the ClO + BrO reaction in a manner that increases OClO formation and decreases BrCl formation leads to lower ClO values calculated for twilight conditions after sunset, resulting in better agreement with ASUR measurements.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy