SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Nowak Jacek) ;pers:(Larsson Matilda)"

Sökning: WFRF:(Nowak Jacek) > Larsson Matilda

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bjällmark, Anna, et al. (författare)
  • Effects of hemodialysis on the cardiovascular system: Quantitative analysis using wave intensity wall analysis and tissue velocity imaging
  • 2010
  • Ingår i: Heart and Vessels. - : Springer Science and Business Media LLC. - 0910-8327 .- 1615-2573.
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiovascular disease is the leading cause of death in patients with end stage renal disease (ESRD). The aim of this study was to investigate the changes in cardiovascular function induced by a single session of hemodialysis (HD) by the analysis of cardiovascular dynamics using wave intensity wall analysis (WIWA) and of systolic and diastolic myocardial function using tissue velocity imaging (TVI). Grey-scale cine loops of the left common carotid artery, conventional echocardiography and TVI images of the left ventricle were acquired before and after HD in 45 patients (17 women, mean age 54) with ESRD. The WIWA indexes, W1 preload-adjusted W1, W2 and preload-adjusted W2, and the TVI variables, isovolumic contraction velocity (IVCV), isovolumic contraction time (IVCT), peak systolic velocity (PSV), displacement, isovolumic relaxation velocity (IVRV), isovolumic relaxation time (IVRT), peak early diastolic velocity (E’) and peak late diastolic velocity (A’), were compared before and after HD. The WIWA measurements showed significant increases in W1 (p < 0.05) and preload-adjusted W1 (p < 0.01) after HD. W2 was significantly decreased (p < 0.05) after HD, whereas the change in preload-adjusted W2 was not significant. Systolic velocities, IVCV (p < 0.001) and PSV (p < 0.01), were increased after HD, whereas the AV-plane displacement were decreased (p < 0.01). For the measured diastolic variables, E’ was significantly decreased (p < 0.01) and IVRT was significantly prolonged (p < 0.05), after HD. A few correlations were found between WIWA and TVI variables. The WIWA and TVI measurements indicate that a single session of HD improves systolic function. The load dependency of the diastolic variables seems to be more pronounced than for the systolic variables. Preload-adjusted wave intensity indexes may contribute in the assessment of true LV contractility and relaxation.
  •  
2.
  •  
3.
  • Hayashi, Shirley Yumi, et al. (författare)
  • Left ventricular mechanical dyssynchrony in patients with different stages of chronic kidney disease and the effects of hemodialysis
  • 2013
  • Ingår i: Hemodialysis International. - : Wiley-Blackwell. - 1492-7535 .- 1542-4758. ; 17:3, s. 346-358
  • Tidskriftsartikel (refereegranskat)abstract
    • Left ventricular (LV) dyssynchrony is a known cause of mortality in patients with heart failure and may possibly play a similar role in patients with chronic kidney disease (CKD) in whom sudden death is one of the most common and as yet not fully explained cause of death. LV synchronicity and its relationship with increased volume load and various biomarkers was analyzed in 145 patients including 53 patients with CKD stages 3 and 4 and in 92 CKD stage 5 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD) using color tissue Doppler imaging and tissue synchronization imaging. The HD patients were evaluated both before and after a single HD session. LV dyssynchrony was defined as a regional difference in time to peak systolic myocardial velocity, between 12 LV segments>105milliseconds. LV dyssynchrony was present in 54% of the patients with no difference between CKD 3 and 4 (58%), HD (48%), and PD (51%). LV dyssynchrony was independently associated with LV mass index and increased estimation of LV end-diastolic pressure. A single HD session resulted in significant changes in LV synchronicity variableswith improvement in 50% of the patientsespecially in patients with higher myocardial systolic velocities and lower LV mass index. Abnormalities in LV synchronicity are highly prevalent in CKD patients already prior to dialysis treatment and are associated with LV hypertrophy, LV dysfunction and load conditions, underlining the importance of volume status for LV synchronicity in CKD patients.
  •  
4.
  • Larsson, Malin, et al. (författare)
  • Visualization of multimodal polymer-shelled contrast agents using ultrasound contrast sequences : an experimental study in a tissue mimicking flow phantom
  • 2013
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 11, s. 33-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: A multimodal polymer-shelled contrast agent (CA) with target specific potential was recently developed and tested for its acoustic properties in a single element transducer setup. Since the developed polymeric CA has different chemical composition than the commercially available CAs, there is an interest to study its acoustic response when using clinical ultrasound systems. The aim of this study was therefore to investigate the acoustic response by studying the visualization capability and shadowing effect of three polymer-shelled CAs when using optimized sequences for contrast imaging. Methods: The acoustic response of three types of the multimodal CA was evaluated in a tissue mimicking flow phantom setup by measuring contrast to tissue ratio (CTR) and acoustic shadowing using five image sequences optimized for contrast imaging. The measurements were performed over a mechanical index (MI) range of 0.2-1.2 at three CA concentrations (10(6), 10(5), 10(4) microbubbles/ml). Results: The CTR-values were found to vary with the applied contrast sequence, MI and CA. The highest CTR-values were obtained when a contrast sequence optimized for higher MI imaging was used. At a CA concentration of 106 microbubbles/ml, acoustic shadowing was observed for all contrast sequences and CAs. Conclusions: The CAs showed the potential to enhance ultrasound images generated by available contrast sequences. A CA concentration of 106 MBs/ml implies a non-linear relation between MB concentration and image intensity.
  •  
5.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy