  • Abul-Kasim, Kasim, et al. (författare)
  • Optimization of Radiation Exposure and Image Quality of the Cone-beam O-arm Intraoperative Imaging System in Spinal Surgery.
  • 2012
  • Ingår i: Journal of Spinal Disorders and Techniques. - 1539-2465. ; 25:1, s. 52-58
  • Tidskriftsartikel (refereegranskat)abstract
    • STUDY DESIGN: Retrospective study. OBJECTIVES: To optimize the radiation doses and image quality for the cone-beam O-arm surgical imaging system in spinal surgery. SUMMARY OF BACKGROUND: Neurovascular compromise has been reported after screw misplacement during thoracic pedicle screw insertion. The use of O-arm with or without navigation system during spinal surgery has been shown to lower the rate of screw misplacement. The main drawback of such imaging surgical systems is the high radiation exposure. METHODS: Chest phantom and cadaveric pig spine were examined on the O-arm with different scan settings: 2 were recommended by the O-arm manufacturer (120 kV/320 mAs, and 120 kV/128 mAs), and 3 low-dose settings (80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs). The radiation doses were estimated by Monte Carlo calculations. Objective evaluation of image quality included interobserver agreement in the measurement of pedicular width in chest phantom and assessment of screw placement in cadaveric pig spine. RESULTS: The effective dose/cm for 120 kV/320 mAs scan was 13, 26, and 69 times higher than those delivered with 80 kV/80 mAs, 80 kV/40 mAs, and 60 kV/40 mAs scans, respectively. Images with 60 kV/40 mAs were unreliable. Images with 80 kV/80 mAs were considered reliable with good interobserver agreement when measuring the pedicular width (random error 0.38 mm and intraclass correlation coefficient 0.979) and almost perfect agreement when evaluating the screw placement (κ value 0.86). CONCLUSIONS: The radiation doses of the O-arm system can be reduced 5 to 13 times without negative impact on image quality with regard to information required for spinal surgery.
  •  
3.
  • Söderberg, Marcus, et al. (författare)
  • Estimation of organ and effective dose to the patient during spinal surgery with a cone-beam O-arm system
  • 2011
  • Ingår i: Medical Imaging 2011: Physics of Medical Imaging. - : SPIE. - 0277-786X .- 1996-756X. ; 7961, s. 79613-79613
  • Konferensbidrag (refereegranskat)abstract
    • The purpose of this study was to estimate organ and effective dose to the patient during spinal surgery with a cone-beam O-arm system. The absorbed dose to radiosensitive organs and effective dose were calculated on mathematically simulated phantom corresponding to a 15-year-old patient using PCXMC 2.0. Radiation doses were calculated at every 15 degrees of the x-ray tube projection angle at two regions: thoracic spine and lumbar spine. Two different scan settings were investigated: 120 kV/128 mAs (standard) and 80 kV/80 mAs (low-dose). The effect on effective dose by changing the number of simulated projection angles (24, 12 and 4) was investigated. Estimated effective dose with PCXMC was compared with calculated effective dose using conversion factors between dose length product (DLP) and effective dose. The highest absorbed doses were received by the breast, lungs (thoracic spine) and stomach (lumbar spine). The effective doses using standard settings were 5 times higher than those delivered with low-dose settings (2-3 scans: 7.9-12 mSv versus 1.5-2.4 mSv). There was no difference in estimated effective dose using 24 or 12 projection angles. Using 4 projection angles at every 90 degrees was not enough to accurate simulate the x-ray tube rotating around the patient. Conversion factors between DLP and effective dose were determined. Our conclusion is that the O-arm has the potential to deliver high radiation doses and consequently there is a strong need to optimize the clinical scan protocols.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3
Typ av publikation
konferensbidrag (2)
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (2)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Abul-Kasim, Kasim (3)
Ohlin, Acke (3)
Gunnarsson, Mikael (3)
Selariu, Eufrozina (2)
Kherad, Mehrsa (2)
Lärosäte
Lunds universitet (3)
Språk
Engelska (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy