SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Olsson K) ;lar1:(kth)"

Sökning: WFRF:(Olsson K) > Kungliga Tekniska Högskolan

  • Resultat 1-10 av 98
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kehoe, Laura, et al. (författare)
  • Make EU trade with Brazil sustainable
  • 2019
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 364:6438, s. 341-
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
  •  
2.
  •  
3.
  • Torbert, R. B., et al. (författare)
  • The FIELDS Instrument Suite on MMS : Scientific Objectives, Measurements, and Data Products
  • 2016
  • Ingår i: Space Science Reviews. - : Springer Science+Business Media B.V.. - 0038-6308 .- 1572-9672. ; 199:1-4, s. 105-135
  • Forskningsöversikt (refereegranskat)abstract
    • The FIELDS instrumentation suite on the Magnetospheric Multiscale (MMS) mission provides comprehensive measurements of the full vector magnetic and electric fields in the reconnection regions investigated by MMS, including the dayside magnetopause and the night-side magnetotail acceleration regions out to 25 Re. Six sensors on each of the four MMS spacecraft provide overlapping measurements of these fields with sensitive cross-calibrations both before and after launch. The FIELDS magnetic sensors consist of redundant flux-gate magnetometers (AFG and DFG) over the frequency range from DC to 64 Hz, a search coil magnetometer (SCM) providing AC measurements over the full whistler mode spectrum expected to be seen on MMS, and an Electron Drift Instrument (EDI) that calibrates offsets for the magnetometers. The FIELDS three-axis electric field measurements are provided by two sets of biased double-probe sensors (SDP and ADP) operating in a highly symmetric spacecraft environment to reduce significantly electrostatic errors. These sensors are complemented with the EDI electric measurements that are free from all local spacecraft perturbations. Cross-calibrated vector electric field measurements are thus produced from DC to 100 kHz, well beyond the upper hybrid resonance whose frequency provides an accurate determination of the local electron density. Due to its very large geometric factor, EDI also provides very high time resolution (similar to 1 ms) ambient electron flux measurements at a few selected energies near 1 keV. This paper provides an overview of the FIELDS suite, its science objectives and measurement requirements, and its performance as verified in calibration and cross-calibration procedures that result in anticipated errors less than 0.1 nT in B and 0.5 mV/m in E. Summaries of data products that result from FIELDS are also described, as well as algorithms for cross-calibration. Details of the design and performance characteristics of AFG/DFG, SCM, ADP, SDP, and EDI are provided in five companion papers.
  •  
4.
  • Yoo, S. J. B., et al. (författare)
  • Spectral phase encoded time spread optical code division multiple access technology for next generation communication networks Invited
  • 2007
  • Ingår i: Journal of Optical Networking. - 1536-5379. ; 6:10, s. 1210-1227
  • Tidskriftsartikel (refereegranskat)abstract
    • We overview and summarize the progress of the spectral phase encoded time spreading (SPECTS) optical code division multiple access (O-CDMA) technology. Recent progress included a demonstration of a 320 Gbit/s (32-user x 10 Gbit/s) all-optical passive optical network testbed based on the SPECTS O-CDMA technology and a theoretical prediction of the spectral efficiency at 100% and above. In particular, InP-based integrated photonics allows implementation of SPECTS O-CDMA transmitters and receivers monolithically integrated on a chip. The integrated InP chip technology not only allows robust and compact configurations for practical and low-cost O-CDMA network deployments but also offers code reconfigurations at rapid rates for secure communication applications.
  •  
5.
  •  
6.
  • Cao, Jing, et al. (författare)
  • Demonstration of Spectral Phase O-CDMA Encoding and Decoding in Monolithically Integrated Arrayed-Waveguide-Grating-Based Encoder
  • 2006
  • Ingår i: IEEE Photonics Technology Letters. - 1041-1135 .- 1941-0174. ; 18:21-24, s. 2602-2604
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on successful spectral phase encoding and decoding operation in a pair of monolithically integrated InP encoder chips, each consisting of an arrayed waveguide grating (AWG) pair and an eight-channel electrooptic phase shifter array. The monolithic fabrication process includes anisotropic reactive ion etching and planarizing hydride-vapor-phase-epitaxy lateral regrowth to realize buried hetero-waveguide structures in AWGs and phase shifters. Electrooptical modulation in the phase shifter arrays in the encoder chip achieved Walsh-code-based optical code-division multiple access (O-CDMA) encoding and decoding. The matched-code encoding-decoding operation resulted in error-free performance in the presence of an interferer, indicating good potential for O-CDMA network applications.
  •  
7.
  • Fontaine, N. K., et al. (författare)
  • Determination of 20 GHz InP AWG phase errors by measurement of AWG pulse train
  • 2007
  • Ingår i: 2007 IEEE LEOS Annual Meeting Conference Proceedings. - : IEEE. - 142440925X - 9781424409259 ; , s. 725-726
  • Konferensbidrag (refereegranskat)abstract
    • The phase errors of a 20 GHz AWG fabricated on InP are determined by measuring the intensity and phase of the pulse train produced by the transmission of a short pulse through an AWG.
  •  
8.
  •  
9.
  • Hober, Sophia, Professor, 1965-, et al. (författare)
  • Systematic evaluation of SARS-CoV-2 antigens enables a highly specific and sensitive multiplex serological COVID-19 assay
  • 2021
  • Ingår i: Clinical & Translational Immunology. - : Wiley. - 2050-0068. ; 10:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective. The COVID-19 pandemic poses an immense need for accurate, sensitive and high-throughput clinical tests, and serological assays are needed for both overarching epidemiological studies and evaluating vaccines. Here, we present the development and validation of a high-throughput multiplex bead-based serological assay. Methods. More than 100 representations of SARS-CoV-2 proteins were included for initial evaluation, including antigens produced in bacterial and mammalian hosts as well as synthetic peptides. The five best-performing antigens, three representing the spike glycoprotein and two representing the nucleocapsid protein, were further evaluated for detection of IgG antibodies in samples from 331 COVID-19 patients and convalescents, and in 2090 negative controls sampled before 2020. Results. Three antigens were finally selected, represented by a soluble trimeric form and the S1-domain of the spike glycoprotein as well as by the C-terminal domain of the nucleocapsid. The sensitivity for these three antigens individually was found to be 99.7%, 99.1% and 99.7%, and the specificity was found to be 98.1%, 98.7% and 95.7%. The best assay performance was although achieved when utilising two antigens in combination, enabling a sensitivity of up to 99.7% combined with a specificity of 100%. Requiring any two of the three antigens resulted in a sensitivity of 99.7% and a specificity of 99.4%. Conclusion. These observations demonstrate that a serological test based on a combination of several SARS-CoV-2 antigens enables a highly specific and sensitive multiplex serological COVID-19 assay.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 98
Typ av publikation
tidskriftsartikel (71)
konferensbidrag (15)
forskningsöversikt (5)
annan publikation (3)
rapport (2)
doktorsavhandling (2)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (80)
övrigt vetenskapligt/konstnärligt (18)
Författare/redaktör
Hedenqvist, Mikael S ... (17)
Lourdudoss, Sebastia ... (16)
Olsson, Richard T. (16)
Olsson, T (13)
Olsson, Fredrik (11)
Baek, J. H. (11)
visa fler...
Soares, F. M. (11)
Fontaine, N. K. (11)
Broeke, R. G. (11)
Yoo, S. J. B. (11)
Cao, J. (10)
Gedde, Ulf W. (9)
Seo, S. W. (9)
Nilsson, Peter (8)
Pourrahimi, Amir Mas ... (8)
Olsson, Richard (8)
Nordlund, K. (8)
Malerba, L. (8)
Olsson, Pär (7)
Jiang, W. (7)
Capezza, Antonio Jos ... (7)
Birdsong, Björn K. (7)
Khademi, M. (6)
Okamoto, K. (6)
Gubanski, Stanislaw, ... (6)
Gronlund, H (6)
Ström, Valter (6)
Gafvelin, G (6)
Hillert, J (5)
Hellström, Cecilia (5)
Kockum, I. (5)
Piehl, F (4)
Olsson, P. (4)
Blomgren, Jan (4)
Atac, Ayse (4)
Pomp, Stephan (4)
Österlund, Michael (4)
Nadel-Turonski, P. (4)
Pin, Elisa (4)
Ergun, R. E. (4)
Holmgren, E. (4)
Dors, I. (4)
Nilsson, Fritjof (4)
Ji, C. (4)
Elmgren, K (4)
Domain, C. (4)
Bronge, M (4)
Dangtip, S (4)
Macri, J. (4)
Rau, D. (4)
visa färre...
Lärosäte
Karolinska Institutet (17)
Uppsala universitet (10)
Chalmers tekniska högskola (9)
Mittuniversitetet (7)
Lunds universitet (5)
visa fler...
Göteborgs universitet (4)
Sveriges Lantbruksuniversitet (3)
Luleå tekniska universitet (2)
Linköpings universitet (2)
Umeå universitet (1)
Stockholms universitet (1)
Malmö universitet (1)
Linnéuniversitetet (1)
Högskolan Dalarna (1)
visa färre...
Språk
Engelska (97)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (54)
Teknik (26)
Medicin och hälsovetenskap (17)
Lantbruksvetenskap (1)
Samhällsvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy