  • Nyholm, Tufve, et al. (författare)
  • MR and CT data with multiobserver delineations of organs in the pelvic areaPart of the Gold Atlas project
  • 2018
  • Ingår i: Med Phys. - : Wiley. - 0094-2405 .- 2473-4209. ; 45:3, s. 1295-1300
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeWe describe a public dataset with MR and CT images of patients performed in the same position with both multiobserver and expert consensus delineations of relevant organs in the male pelvic region. The purpose was to provide means for training and validation of segmentation algorithms and methods to convert MR to CT like data, i.e., so called synthetic CT (sCT). Acquisition and validation methodsT1- and T2-weighted MR images as well as CT data were collected for 19 patients at three different departments. Five experts delineated nine organs for each patient based on the T2-weighted MR images. An automatic method was used to fuse the delineations. Starting from each fused delineation, a consensus delineation was agreed upon by the five experts for each organ and patient. Segmentation overlap between user delineations with respect to the consensus delineations was measured to describe the spread of the collected data. Finally, an open-source software was used to create deformation vector fields describing the relation between MR and CT images to further increase the usability of the dataset. Data format and usage notesThe dataset has been made publically available to be used for academic purposes, and can be accessed from . Potential applicationsThe dataset provides a useful source for training and validation of segmentation algorithms as well as methods to convert MR to CT-like data (sCT). To give some examples: The T2-weighted MR images with their consensus delineations can directly be used as a template in an existing atlas-based segmentation engine; the expert delineations are useful to validate the performance of a segmentation algorithm as they provide a way to measure variability among users which can be compared with the result of an automatic segmentation; and the pairwise deformably registered MR and CT images can be a source for an atlas-based sCT algorithm or for validation of sCT algorithm. (c) 2018 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
  •  
2.
  • Olsson, Lars E, et al. (författare)
  • Basic concepts and applications of functional magnetic resonance imaging for radiotherapy of prostate cancer
  • 2019
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 9, s. 50-57
  • Tidskriftsartikel (refereegranskat)abstract
    • Recently, the interest to integrate magnetic resonance imaging (MRI) in radiotherapy for prostate cancer has increased considerably. MRI can contribute in all steps of the radiotherapy workflow from diagnosis, staging, and target definition to treatment follow-up. Of particular interest is the ability of MRI to provide a wide range of functional measures. The complexity of MRI as an imaging modality combined with the growing interest of the application to prostate cancer radiotherapy, emphasize the need for dedicated education within the radiation oncology community. In this context, an overview of the most common as well as a few upcoming functional MR imaging techniques is presented: the basic methodology and measurement is described, the link between the functional measures and the underlying biology is established, and finally relevant applications of functional MRI useful for prostate cancer radiotherapy are given.
  •  
3.
  • Persson, Emilia, et al. (författare)
  • MR-OPERA : A Multicenter/Multivendor Validation of Magnetic Resonance Imaging-Only Prostate Treatment Planning Using Synthetic Computed Tomography Images
  • 2017
  • Ingår i: International Journal of Radiation Oncology, Biology, Physics. - : ELSEVIER SCIENCE INC. - 0360-3016 .- 1879-355X. ; 99:3, s. 692-700
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaginge-only workflow for 170 prostate cancer patients.Methods and Materials: The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a cloud-based service. A T2-weighted MR sequence, covering the body contour, was added to the clinical protocol. The MR images were sent from the MR scanner workstation to theMriPlanner platform. The sCT was automatically returned to the treatment planning system. Four MR scanners and 2 magnetic field strengths were included in the study. For each patient, a CT-treatment plan was created and approved according to clinical practice. The sCT was rigidly registered to the CT, and the clinical treatment plan was recalculated on the sCT. The dose distributions from the CT plan and the sCT plan were compared according to a set of dose-volume histogram parameters and gamma evaluation. Treatment techniques included volumetric modulated arc therapy, intensity modulated radiation therapy, and conventional treatment using 2 treatment planning systems and different dose calculation algorithms.Results: The overall (multicenter/multivendor) mean dose differences between sCT and CT dose distributions were below 0.3% for all evaluated organs and targets. Gamma evaluation showed a mean pass rate of 99.12% (0.63%, 1 SD) in the complete body volume and 99.97% (0.13%, 1 SD) in the planning target volume using a 2%/ 2-mm global gamma criteria.Conclusions: Results of the study show that the sCT conversion method can be used clinically, with minimal differences between sCT and CT dose distributions for target and relevant organs at risk. The small differences seen are consistent between centers, indicating that an MR imagingeonly workflow using MriPlanner is robust for a variety of field strengths, vendors, and treatment techniques.
  •  