SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ostlund O) ;lar1:(lu)"

Sökning: WFRF:(Ostlund O) > Lunds universitet

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Jernberg, T., et al. (författare)
  • Long-Term Effects of Oxygen Therapy on Death or Hospitalization for Heart Failure in Patients With Suspected Acute Myocardial Infarction
  • 2018
  • Ingår i: Circulation. - : Ovid Technologies (Wolters Kluwer Health). - 0009-7322 .- 1524-4539. ; 138:24, s. 2754-2762
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: In the DETO2X-AMI trial (Determination of the Role of Oxygen in Suspected Acute Myocardial Infarction), we compared supplemental oxygen with ambient air in normoxemic patients presenting with suspected myocardial infarction and found no significant survival benefit at 1 year. However, important secondary end points were not yet available. We now report the prespecified secondary end points cardiovascular death and the composite of all-cause death and hospitalization for heart failure. METHODS: In this pragmatic, registry-based randomized clinical trial, we used a nationwide quality registry for coronary care for trial procedures and evaluated end points through the Swedish population registry (mortality), the Swedish inpatient registry (heart failure), and cause of death registry (cardiovascular death). Patients with suspected acute myocardial infarction and oxygen saturation of >= 90% were randomly assigned to receive either supplemental oxygen at 6 L/min for 6 to 12 hours delivered by open face mask or ambient air. RESULTS: A total of 6629 patients were enrolled. Acute heart failure treatment, left ventricular systolic function assessed by echocardiography, and infarct size measured by high-sensitive cardiac troponin T were similar in the 2 groups during the hospitalization period. All-cause death or hospitalization for heart failure within 1 year after randomization occurred in 8.0% of patients assigned to oxygen and in 7.9% of patients assigned to ambient air (hazard ratio, 0.99; 95% CI, 0.84-1.18; P=0.92). During long-term follow-up (median [range], 2.1 [1.0-3.7] years), the composite end point occurred in 11.2% of patients assigned to oxygen and in 10.8% of patients assigned to ambient air (hazard ratio, 1.02; 95% CI, 0.88-1.17; P=0.84), and cardiovascular death occurred in 5.2% of patients assigned to oxygen and in 4.8% assigned to ambient air (hazard ratio, 1.07; 95% CI, 0.87-1.33; P=0.52). The results were consistent across all predefined subgroups. CONCLUSIONS: Routine use of supplemental oxygen in normoxemic patients with suspected myocardial infarction was not found to reduce the composite of all-cause mortality and hospitalization for heart failure, or cardiovascular death within 1 year or during long-term follow-up.
  •  
3.
  • O'Byrne, P. M., et al. (författare)
  • Measuring asthma control: a comparison of three classification systems
  • 2010
  • Ingår i: European Respiratory Journal. - : European Respiratory Society (ERS). - 1399-3003 .- 0903-1936. ; 36:2, s. 269-276
  • Tidskriftsartikel (refereegranskat)abstract
    • There are various ways to classify asthma control; however, no classification is universally accepted. This retrospective analysis compared asthma control as assessed by the Asthma Control Questionnaire (5-item version; ACQ-5), Global Initiative for Asthma (GINA) or Gaining Optimal Asthma Control (GOAL) study criteria. Pooled data at the final study week (n=8,188) from three budesonide/formoterol maintenance and reliever therapy studies which measured ACQ-5 were stratified according to GINA or GOAL criteria and ACQ-5 score distribution. The percentages of patients with a controlled/partly controlled week (GINA), totally/well-controlled week (GOAL) and range of ACQ-5 cut-off points were compared. Patients with GINA controlled, partly controlled and uncontrolled asthma had mean ACQ-5 scores of 0.43, 0.75 and 1.62, respectively. Patients with GOAL totally controlled, well-controlled and uncontrolled asthma had ACQ-5 scores of 0.39, 0.78 and 1.63. The kappa measure of agreement was 0.80 for GINA and GOAL criteria, and 0.63 for GINA controlled/partly controlled and ACQ-5 <1.00. ACQ-5 detected clinically important improvements in 49% of patients who, according to GINA criteria, remained uncontrolled at the end of the study. Asthma control measured by GINA or GOAL criteria provides similar results. GINA Controlled/Partly Controlled and GOAL Totally Controlled/Well-Controlled correspond to ACQ-5 <1.00. The ACQ-5 is more responsive to change in a clinical trial setting than a categorical scale.
  •  
4.
  • Reddel, H. K., et al. (författare)
  • Effect of different asthma treatments on risk of cold-related exacerbations
  • 2011
  • Ingår i: European Respiratory Journal. - : European Respiratory Society (ERS). - 1399-3003 .- 0903-1936. ; 38:3, s. 584-593
  • Tidskriftsartikel (refereegranskat)abstract
    • Common colds often trigger asthma exacerbations. The present study compared cold-related severe exacerbations during budesonide/formoterol maintenance and reliever therapy, and different regimens of maintenance inhaled corticosteroids (ICS), with or without long-acting beta(2)-agonists (LABA), and with as-needed short-acting beta(2)-agonists (SABA) or LABA. Reported colds and severe exacerbations (defined by oral corticosteroid use and/or hospitalisation/emergency room visit) were assessed for 12,507 patients during 6-12 months of double-blind treatment. Exacerbations occurring <= 14 days after onset of reported colds were analysed by a Poisson model. The incidence of colds was similar across treatments. Asthma symptoms and reliever use increased during colds. Budesonide/formoterol maintenance and reliever therapy reduced severe cold-related exacerbations by 36% versus pooled comparators plus SABA (rate ratio (RR) 0.64; p=0.002), and for individual treatment comparisons, by 52% versus the same maintenance dose of ICS/LABA (RR 0.48; p < 0.001); there were nonsignificant reductions versus higher maintenance doses of ICS or ICS/LABA (RR 0.83 and 0.72, respectively). As-needed LABA did not reduce cold-related exacerbations versus as-needed SABA (RR 0.96). Severe cold-related exacerbations were reduced by budesonide/formoterol maintenance and reliever therapy compared with ICS with or without LABA and with as-needed SABA. Subanalyses suggested the importance of the ICS component in reducing cold-related exacerbations. Future studies should document the cause of exacerbations, in order to allow identification of different treatment effects.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy