Microcontact imprinting based surface plasmon resonance (SPR) biosensor for real-time and ultrasensitive detection of prostate specific antigen (PSA) from clinical samples

Erturk, Gizem (author)
Hacettepe University
Ozen, Haluk (author)
Tumer, M. Askin (author)
show more...
Mattiasson, Bo (author)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Denizli, Adil (author)
show less...
 (creator_code:org_t)
Elsevier BV, 2016
2016
English.
In: Sensors and Actuators B: Chemical. - : Elsevier BV. - 0925-4005. ; 224, s. 823-832
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Prostate specific antigen (PSA) is an important biomarker for diagnosis and prognosis of prostate cancer. Herein, microcontact PSA-imprinted surface plasmon resonance (SPR) sensor chip was developed for sensitive, real-time detection of PSA. The imprinted chip was prepared in the presence of methacrylic acid (MAA) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker via UV polymerization using microcontact imprinting technique. PSA imprinted SPR sensor chip was characterized by atomic force microscope (AFM), scanning electron microscope (SEM), ellipsometry, dispersive Raman and Fourier transform infrared spectroscopy (FT-IR). Under optimal conditions, PSA detection was performed with standard PSA solutions in the concentration range of 0.1-50 ng mL(-1) with a detection limit (LOD) of approximately 91 pg mL(-1) (18 x 10(-14) M). Selectivity studies were performed against human serum albumin (HSA) and lysozyme (Lyz) as the competitive agents. The developed system was evaluated for analysis of 10 clinical serum samples and showed approximately 98% agreement between the results obtained by commercial enzyme-linked immunosorbent assay (ELISA) method without significant differences at the 0.05 significance level (p = 0.751, p >0.05). (C) 2015 Elsevier B.V. All rights reserved.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Prostate specific antigen
Surface plasmon resonance
Microcontact
imprinting
Enzyme-linked immunosorbent assay

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Erturk, Gizem
Ozen, Haluk
Tumer, M. Askin
Mattiasson, Bo
Denizli, Adil
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Sensors and Actu ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view