SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Pfeiffer Andreas) ;hsvcat:2"

Sökning: WFRF:(Pfeiffer Andreas) > Teknik

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ehn, Sebastian, et al. (författare)
  • X-ray deconvolution microscopy
  • 2016
  • Ingår i: Biomedical Optics Express. - 2156-7085. ; 7:4, s. 1227-1239
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent advances in single-photon-counting detectors are enabling the development of novel approaches to reach micrometer-scale resolution in x-ray imaging. One example of such a technology are the MEDIPIX3RX-based detectors, such as the LAMBDA which can be operated with a small pixel size in combination with real-time on-chip charge-sharing correction. This characteristic results in a close to ideal, box-like point spread function which we made use of in this study. The proposed method is based on raster-scanning the sample with sub-pixel sized steps in front of the detector. Subsequently, a deconvolution algorithm is employed to compensate for blurring introduced by the overlap of pixels with a well defined point spread function during the raster-scanning. The presented approach utilizes standard laboratory x-ray equipment while we report resolutions close to 10 mu m. The achieved resolution is shown to follow the relationship p/n with the pixel-size p of the detector and the number of raster-scanning steps n. (C) 2016 Optical Society of America
  •  
2.
  • Asghar, Adeel, et al. (författare)
  • Automatic Regression Testing of Simulation Models and Concept for Simulation of Connected FMUs in PySimulator
  • 2015
  • Ingår i: Proceedings of the 11th International Modelica Conference. - Linköping : Linköping University Electronic Press. - 9789176859551 ; , s. 671-679
  • Konferensbidrag (refereegranskat)abstract
    • The Modelica and FMI tool ecosystem is growing each year with new tools and methods becoming available. The open Modelica standard promises portability but it is important to ensure that a certain model behaves the same in different Modelica tools or in a different version of the same tool. It is also very important (for model evolution) to check that a new version of the same model produces comparable results. Finally, it is desirable to verify that a model exported in FMU form from a Modelica tool gives exactly the same results as the original model. This paper presents a framework for automatic regression testing as part of PySimulator which provides an efficient and concise way of testing if a model or a range of models behaves in the same way in several tools or versions of a tool by checking that the results produced are essentially identical. The FMI standard has been adopted by many tool vendors and is growing in popularity each year. This paper proposes a concept for building and simulating a system made from connected FMUs generated by different tools. The FMUs for Co-Simulation can be connected together using a GUI. The system model built graphically in this way can be saved for later use or simulated directly inside PySimulator. Active development is going on to support simulation of connected FMUs for Model Exchange.
  •  
3.
  • Hemmeter, Andreas, et al. (författare)
  • Terahertz Rectennas on Flexible Substrates Based on One-Dimensional Metal–Insulator–Graphene Diodes
  • 2021
  • Ingår i: ACS Applied Electronic Materials. - : American Chemical Society (ACS). - 2637-6113. ; 3:9, s. 3747-3753
  • Tidskriftsartikel (refereegranskat)abstract
    • Flexible energy harvesting devices fabricated in scalable thin-film processes are crucial for wearable electronics and the Internet of Things. We present a flexible rectenna based on a one-dimensional junction metal–insulator–graphene diode, offering low-noise power detection at terahertz (THz) frequencies. The rectennas are fabricated on a flexible polyimide film in a scalable process by photolithography using graphene grown by chemical vapor deposition. A one-dimensional junction reduces the junction capacitance and enables operation up to 170 GHz. The rectenna shows a maximum responsivity of 80 V/W at 167 GHz in free space measurements and minimum noise equivalent power of 80 pW/√Hz.
  •  
4.
  • Messner, Christoph B., et al. (författare)
  • Ultra-High-Throughput Clinical Proteomics Reveals Classifiers of COVID-19 Infection
  • 2020
  • Ingår i: Cell Systems. - : Elsevier BV. - 2405-4712 .- 2405-4720. ; 11:1, s. 11-24.E4
  • Tidskriftsartikel (refereegranskat)abstract
    • The COVID-19 pandemic is an unprecedented global challenge, and point-of-care diagnostic classifiers are urgently required. Here, we present a platform for ultra-high-throughput serum and plasma proteomics that builds on ISO13485 standardization to facilitate simple implementation in regulated clinical laboratories. Our low-cost workflow handles up to 180 samples per day, enables high precision quantification, and reduces batch effects for large-scale and longitudinal studies. We use our platform on samples collected from a cohort of early hospitalized cases of the SARS-CoV-2 pandemic and identify 27 potential biomarkers that are differentially expressed depending on the WHO severity grade of COVID-19. They include complement factors, the coagulation system, inflammation modulators, and pro-inflammatory factors upstream and downstream of interleukin 6. All protocols and software for implementing our approach are freely available. In total, this work supports the development of routine proteomic assays to aid clinical decision making and generate hypotheses about potential COVID-19 therapeutic targets.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy