  • Simundic, Ana-Maria, et al. (author)
  • Compliance of blood sampling procedures with the CLSI H3-A6 guidelines : an observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE)
  • 2015
  • In: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter. - 1434-6621 .- 1437-4331. ; 53:9, s. 1321-1331
  • Journal article (peer-reviewed)abstract
    • Background: An observational study was conducted in 12 European countries by the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) to assess the level of compliance with the CLSI H3-A6 guidelines. Methods: A structured checklist including 29 items was created to assess the compliance of European phlebotomy procedures with the CLSI H3-A6 guideline. A risk occurrence chart of individual phlebotomy steps was created from the observed error frequency and severity of harm of each guideline key issue. The severity of errors occurring during phlebotomy was graded using the risk occurrence chart. Results: Twelve European countries participated with a median of 33 (18-36) audits per country, and a total of 336 audits. The median error rate for the total phlebotomy procedure was 26.9 % (10.6-43.8), indicating a low overall compliance with the recommended CLSI guideline. Patient identification and test tube labelling were identified as the key guideline issues with the highest combination of probability and potential risk of harm. Administrative staff did not adhere to patient identification procedures during phlebotomy, whereas physicians did not adhere to test tube labelling policy. Conclusions: The level of compliance of phlebotomy procedures with the CLSI H3-A6 guidelines in 12 European countries was found to be unacceptably low. The most critical steps in need of immediate attention in the investigated countries are patient identification and tube labelling.
  •  
2.
  • Simundic, Ana-Maria, et al. (author)
  • Joint EFLM-COLABIOCLI recommendation for venous blood sampling
  • 2018
  • In: Clinical Chemistry and Laboratory Medicine. - Berlin : Walter de Gruyter. - 1434-6621 .- 1437-4331. ; 56:12, s. 2015-2038
  • Journal article (peer-reviewed)abstract
    • This document provides a joint recommendation for venous blood sampling of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) and Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin America Confederation of Clinical Biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-to-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Post-sampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety.
  •  
3.
  • Simundic, Ana-Maria, et al. (author)
  • Raccomandazione congiunta EFLM-COLABIOCLI per il prelievo di sangue venoso : [Joint EFLM-COLABIOCLI recommendation for venous blood sampling]
  • 2019
  • In: Biochimica Clinica. - 0393-0564 .- 0392-7091. ; 43:2, s. 204-227
  • Research review (peer-reviewed)abstract
    • This document provides a joint recommendation for venous blood sampling of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) and Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin America Confederation of Clinical Biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-to-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Postsampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety.
  •  