SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Pistolesi E.) "

Sökning: WFRF:(Pistolesi E.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S., et al. (författare)
  • Electroweak measurements in electron positron collisions at W-boson-pair energies at LEP
  • 2013
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 532:4, s. 119-244
  • Forskningsöversikt (refereegranskat)abstract
    • Electroweak measurements performed with data taken at the electron positron collider LEP at CERN from 1995 to 2000 are reported. The combined data set considered in this report corresponds to a total luminosity of about 3 fb(-1) collected by the four LEP experiments ALEPH, DELPHI, 13 and OPAL, at centre-of-mass energies ranging from 130 GeV to 209 GeV. Combining the published results of the four LEP experiments, the measurements include total and differential cross-sections in photon-pair, fermion-pair and four-fermion production, the latter resulting from both double-resonant WW and ZZ production as well as singly resonant production. Total and differential cross-sections are measured precisely, providing a stringent test of the Standard Model at centre-of-mass energies never explored before in electron positron collisions. Final-state interaction effects in four-fermion production, such as those arising from colour reconnection and Bose Einstein correlations between the two W decay systems arising in WW production, are searched for and upper limits on the strength of possible effects are obtained. The data are used to determine fundamental properties of the W boson and the electroweak theory. Among others, the mass and width of the W boson, m(w) and Gamma(w), the branching fraction of W decays to hadrons, B(W -> had), and the trilinear gauge-boson self-couplings g(1)(Z), K-gamma and lambda(gamma), are determined to be: m(w) = 80.376 +/- 0.033 GeV Gamma(w) = 2.195 +/- 0.083 GeV B(W -> had) = 67.41 +/- 0.27% g(1)(Z) = 0.984(-0.020)(+0.018) K-gamma - 0.982 +/- 0.042 lambda(gamma) = 0.022 +/- 0.019. (C) 2013 Elsevier B.V. All rights reserved.
  •  
2.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
3.
  • Sakornsakolpat, Phuwanat, et al. (författare)
  • Genetic landscape of chronic obstructive pulmonary disease identifies heterogeneous cell-type and phenotype associations
  • 2019
  • Ingår i: Nature Genetics. - : Springer Science and Business Media LLC. - 1061-4036 .- 1546-1718. ; 51:3, s. 494-505
  • Tidskriftsartikel (refereegranskat)abstract
    • Chronic obstructive pulmonary disease (COPD) is the leading cause of respiratory mortality worldwide. Genetic risk loci provide new insights into disease pathogenesis. We performed a genome-wide association study in 35,735 cases and 222,076 controls from the UK Biobank and additional studies from the International COPD Genetics Consortium. We identified 82 loci associated with P < 5 x 10-8; 47 of these were previously described in association with either COPD or population-based measures of lung function. Of the remaining 35 new loci, 13 were associated with lung function in 79,055 individuals from the SpiroMeta consortium. Using gene expression and regulation data, we identified functional enrichment of COPD risk loci in lung tissue, smooth muscle, and several lung cell types. We found 14 COPD loci shared with either asthma or pulmonary fibrosis. COPD genetic risk loci clustered into groups based on associations with quantitative imaging features and comorbidities. Our analyses provide further support for the genetic susceptibility and heterogeneity of COPD.
  •  
4.
  • O'Byrne P, M., et al. (författare)
  • Budesonide/Formoterol combination therapy as both maintenance and reliever medication in asthma
  • 2005
  • Ingår i: Am J Respir Crit Care Med. ; 171:2, s. 129-36
  • Tidskriftsartikel (refereegranskat)abstract
    • Asthma control is improved by combining inhaled corticosteroids with long-acting beta(2)-agonists. However, fluctuating asthma control still occurs. We hypothesized that in patients receiving low maintenance dose budesonide/formoterol (bud/form), replacing short-acting beta(2)-agonist (SABA) reliever with as-needed bud/form would provide rapid symptom relief and simultaneous adjustment in antiinflammatory therapy, thereby reducing exacerbations. In this double-blind, randomized, parallel-group study, 2,760 patients with asthma aged 4-80 years (FEV(1) 60-100% predicted) received either terbutaline 0.4 mg as SABA with bud/form 80/4.5 mug twice a day (bud/form + SABA) or bud 320 mug twice a day (bud + SABA) or bud/form 80/4.5 mug twice a day with 80/4.5 mug as-needed (bud/form maintenance + relief). Children used a once-nocte maintenance dose. Bud/form maintenance + relief prolonged time to first severe exacerbation (p < 0.001; primary endpoint), resulting in a 45-47% lower exacerbation risk versus bud/form + SABA (hazard ratio, 0.55; 95% confidence interval, 0.44, 0.67) or bud + SABA (hazard ratio, 0.53; 95% confidence interval 0.43, 0.65). Bud/form maintenance + relief also prolonged the time to the first, second, and third exacerbation requiring medical intervention (p < 0.001), reduced severe exacerbation rate, and improved symptoms, awakenings, and lung function compared with both fixed dosing regimens.
  •  
5.
  • Stein, Paul D., et al. (författare)
  • Controversies in Diagnosis of Pulmonary Embolism
  • 2011
  • Ingår i: Clinical and Applied Thrombosis/Hemostasis. - : SAGE Publications. - 1938-2723 .- 1076-0296. ; 17:2, s. 140-149
  • Tidskriftsartikel (refereegranskat)abstract
    • The approach to the diagnosis of acute pulmonary embolism (PE) is under constant revision with advances in technology, noninvasive approaches, and increasing awareness of the risks of ionizing radiation. Optimal approaches in some categories of patients are controversial. Data are insufficient for evidence-based recommendations. Therefore, this survey of investigators in the field was undertaken. Even among experts there were marked differences of opinion regarding the approach to the diagnosis of acute PE. Although CT pulmonary angiography was usually the imaging test of choice, the respondents were keenly aware of the dangers of ionizing radiation. In view of advances in scintigraphic diagnosis since the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) trial, ventilation/perfusion (V/Q) lung scans or perfusion scans alone and single photon emission computed tomography (SPECT) V/Q lung scans are often recommended. The choice depends on the patient's age, gender, and complexity of the findings on the plain chest radiograph.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy