SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Saraste A) ;lar1:(uu)"

Sökning: WFRF:(Saraste A) > Uppsala universitet

  • Resultat 1-10 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bouyoucef, S E, et al. (författare)
  • Poster Session 2 : Monday 4 May 2015, 08
  • 2015
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 16 Suppl 1
  • Tidskriftsartikel (refereegranskat)
  •  
2.
  • Ferreira, Mjv, et al. (författare)
  • Poster Session 3 : Tuesday 5 May 2015, 08
  • 2015
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 16 Suppl 1
  • Tidskriftsartikel (refereegranskat)
  •  
3.
  •  
4.
  • Koffert, J. P., et al. (författare)
  • Metformin treatment significantly enhances intestinal glucose uptake in patients with type 2 diabetes: Results from a randomized clinical trial
  • 2017
  • Ingår i: Diabetes Research and Clinical Practice. - : Elsevier BV. - 0168-8227 .- 1872-8227. ; 131, s. 208-216
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims Metformin therapy is associated with diffuse intestinal 18F-fluoro-deoxyglucose (FDG) accumulation in clinical diagnostics using routine FDG-PET imaging. We aimed to study whether metformin induced glucose uptake in intestine is associated with the improved glycaemic control in patients with type 2 diabetes. Therefore, we compared the effects of metformin and rosiglitazone on intestinal glucose metabolism in patients with type 2 diabetes in a randomized placebo controlled clinical trial, and further, to understand the underlying mechanism, evaluated the effect of metformin in rats. Methods Forty-one patients with newly diagnosed type 2 diabetes were randomized to metformin (1g, b.i.d), rosiglitazone (4mg, b.i.d), or placebo in a 26-week double-blind trial. Tissue specific intestinal glucose uptake was measured before and after the treatment period using FDG-PET during euglycemic hyperinsulinemia. In addition, rats were treated with metformin or vehicle for 12weeks, and intestinal FDG uptake was measured in vivo and with autoradiography. Results Glucose uptake increased 2-fold in the small intestine and 3-fold in the colon for the metformin group and associated with improved glycemic control. Rosiglitazone increased only slightly intestinal glucose uptake. In rodents, metformin treatment enhanced intestinal FDG retention (P=0.002), which was localized in the mucosal enterocytes of the small intestine. Conclusions Metformin treatment significantly enhances intestinal glucose uptake from the circulation of patients with type 2 diabetes. This intestine-specific effect is associated with improved glycemic control and localized to mucosal layer. These human findings demonstrate directs effect of metformin on intestinal metabolism and elucidate the actions of metformin. Clinical trial number NCT02526615 © 2017 The Authors
  •  
5.
  • Besson, Florent L, et al. (författare)
  • A systematic review for the evidence of recommendations and guidelines in hybrid nuclear cardiovascular imaging.
  • 2024
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - 1619-7070 .- 1619-7089.
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: This study aimed to evaluate the level of evidence of expert recommendations and guidelines for clinical indications and procedurals in hybrid nuclear cardiovascular imaging.METHODS: From inception to August 2023, a PubMed literature analysis of the latest version of guidelines for clinical hybrid cardiovascular imaging techniques including SPECT(/CT), PET(/CT), and PET(/MRI) was performed in two categories: (1) for clinical indications for all-in primary diagnosis; subgroup in prognosis and therapy evaluation; and for (2) imaging procedurals. We surveyed to what degree these followed a standard methodology to collect the data and provide levels of evidence, and for which topic systematic review evidence was executed.RESULTS: A total of 76 guidelines, published between 2013 and 2023, were included. The evidence of guidelines was based on systematic reviews in 7.9% of cases, non-systematic reviews in 47.4% of cases, a mix of systematic and non-systematic reviews in 19.7%, and 25% of guidelines did not report any evidence. Search strategy was reported in 36.8% of cases. Strengths of recommendation were clearly reported in 25% of guidelines. The notion of external review was explicitly reported in 23.7% of cases. Finally, the support of a methodologist was reported in 11.8% of the included guidelines.CONCLUSION: The use of evidence procedures for developing for evidence-based cardiovascular hybrid imaging recommendations and guidelines is currently suboptimal, highlighting the need for more standardized methodological procedures.
  •  
6.
  • Danad, Ibrahim, et al. (författare)
  • Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [O-15]H2O PET Imaging
  • 2014
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097 .- 1558-3597. ; 64:14, s. 1464-1475
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Recent studies have demonstrated improved diagnostic accuracy for detecting coronary artery disease (CAD) when myocardial blood flow (MBF) is quantified in absolute terms, but there are no uniformly accepted cutoff values for hemodynamically significant CAD. OBJECTIVES The goal of this study was to determine cutoff values for absolute MBF and to evaluate the diagnostic accuracy of quantitative [O-15]H2O positron emission tomography (PET). METHODS A total of 330 patients underwent both quantitative [O-15]H2O PET imaging and invasive coronary angiography in conjunction with fractional flow reserve measurements. A stenosis >90% and/or fractional flow reserve <= 0.80 was considered obstructive; a stenosis <30% and/or fractional flow reserve >0.80 was nonobstructive. RESULTS Hemodynamically significant CAD was diagnosed in 116 (41%) of 281 patients who fulfilled study criteria for CAD. Resting perfusion was 1.00 +/- 0.25 and 0.92 +/- 0.23 ml/min/g in regions supplied by nonstenotic and significantly stenosed vessels, respectively (p < 0.001). During stress, perfusion increased to 3.26 +/- 1.04 ml/min/g and 1.73 +/- 0.67 ml/min/g, respectively (p < 0.001). The optimal cutoff values were 2.3 and 2.5 for hyperemic MBF and myocardial flow reserve, respectively. For MBF, these cutoff values showed a sensitivity, specificity, and accuracy for detecting significant CAD of 89%, 84%, and 86%, respectively, at a per-patient level and 87%, 85%, and 85% at a per-vessel level. The corresponding myocardial flow reserve values were 86%, 72%, and 78% (per patient) and 80%, 82%, and 81% (per vessel). Age and sex significantly affected diagnostic accuracy of quantitative PET. CONCLUSIONS Quantitative MBF measurements with the use of [O-15]H2O PET provided high diagnostic performance, but both sex and age should be taken into account.
  •  
7.
  • Hoek, Roel, et al. (författare)
  • Determining Hemodynamically Significant Coronary Artery Disease : Patient-Specific Cutoffs in Quantitative Myocardial Blood Flow Using [15O]H2O PET Imaging
  • 2024
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667. ; 65:7, s. 1113-1121
  • Tidskriftsartikel (refereegranskat)abstract
    • Currently, cutoffs of quantitative [15O]H2O PET to detect fractional flow reserve (FFR)-defined coronary artery disease (CAD) were derived from a single cohort that included patients without prior CAD. However, prior CAD, sex, and age can influence myocardial blood flow (MBF). Therefore, the present study determined the influence of prior CAD, sex, and age on optimal cutoffs of hyperemic MBF (hMBF) and coronary flow reserve (CFR) and evaluated whether cutoff optimization enhanced diagnostic performance of quantitative [15O]H2O PET against an FFR reference standard. Methods: Patients with chronic coronary symptoms underwent [15O]H2O PET and invasive coronary angiography with FFR. Optimal cutoffs for patients with and without prior CAD and subpopulations based on sex and age were determined. Results: This multicenter study included 560 patients. Optimal cutoffs were similar for patients with (n = 186) and without prior CAD (hMBF, 2.3 vs. 2.3 mL center dot min-1 center dot g-1; CFR, 2.7 vs. 2.6). Females (n = 190) had higher hMBF cutoffs than males (2.8 vs. 2.3 mL center dot min-1 center dot g-1), whereas CFRs were comparable (2.6 vs. 2.7). However, female sex-specific hMBF cutoff implementation decreased diagnostic accuracy as compared with the cutoff of 2.3 mL center dot min-1 center dot g-1 (72% vs. 82%, P , 0.001). Patients aged more than 70 y (n = 79) had lower hMBF (1.7 mL center dot min-1 center dot g-1) and CFR (2.3) cutoffs than did patients aged 50 y or less, 51-60 y, and 61-70 y (hMBF, 2.3-2.4 mL center dot min-1 center dot g-1; CFR, 2.7). Age-specific cutoffs in patients aged more than 70 y yielded comparable accuracy to the previously established cutoffs (hMBF, 72% vs. 76%, P = 0.664; CFR, 80% vs. 75%, P = 0.289). Conclusion: Patients with and without prior CAD had similar [15O]H2O PET cutoffs for detecting FFR-defined significant CAD. Stratifying patients according to sex and age led to different optimal cutoffs; however, these values did not translate into an increased overall accuracy as compared with previously established thresholds for MBF.
  •  
8.
  • Slart, Riemer H. J. A., et al. (författare)
  • Position paper of the EACVI and EANM on artificial intelligence applications in multimodality cardiovascular imaging using SPECT/CT, PET/CT, and cardiac CT
  • 2021
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer. - 1619-7070 .- 1619-7089. ; 48:5, s. 1399-1413
  • Tidskriftsartikel (refereegranskat)abstract
    • In daily clinical practice, clinicians integrate available data to ascertain the diagnostic and prognostic probability of a disease or clinical outcome for their patients. For patients with suspected or known cardiovascular disease, several anatomical and functional imaging techniques are commonly performed to aid this endeavor, including coronary computed tomography angiography (CCTA) and nuclear cardiology imaging. Continuous improvement in positron emission tomography (PET), single-photon emission computed tomography (SPECT), and CT hardware and software has resulted in improved diagnostic performance and wide implementation of these imaging techniques in daily clinical practice. However, the human ability to interpret, quantify, and integrate these data sets is limited. The identification of novel markers and application of machine learning (ML) algorithms, including deep learning (DL) to cardiovascular imaging techniques will further improve diagnosis and prognostication for patients with cardiovascular diseases. The goal of this position paper of the European Association of Nuclear Medicine (EANM) and the European Association of Cardiovascular Imaging (EACVI) is to provide an overview of the general concepts behind modern machine learning-based artificial intelligence, highlights currently prefered methods, practices, and computational models, and proposes new strategies to support the clinical application of ML in the field of cardiovascular imaging using nuclear cardiology (hybrid) and CT techniques.
  •  
9.
  • Slart, Riemer H. J. A., et al. (författare)
  • Procedural recommendations of cardiac PET/CT imaging : standardization in inflammatory-, infective-, infiltrative-, and innervation (4Is)-related cardiovascular diseases: a joint collaboration of the EACVI and the EANM
  • 2021
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer. - 1619-7070 .- 1619-7089. ; 48:4, s. 1016-1039
  • Tidskriftsartikel (refereegranskat)abstract
    • With this document, we provide a standard for PET/(diagnostic) CT imaging procedures in cardiovascular diseases that are inflammatory, infective, infiltrative, or associated with dysfunctional innervation (4Is). This standard should be applied in clinical practice and integrated in clinical (multicenter) trials for optimal procedural standardization. A major focus is put on procedures using [18F]FDG, but 4Is PET radiopharmaceuticals beyond [18F]FDG are also described in this document. Whilst these novel tracers are currently mainly applied in early clinical trials, some multicenter trials are underway and we foresee in the near future their use in clinical care and inclusion in the clinical guidelines. Finally, PET/MR applications in 4Is cardiovascular diseases are also briefly described. Diagnosis and management of 4Is-related cardiovascular diseases are generally complex and often require a multidisciplinary approach by a team of experts. The new standards described herein should be applied when using PET/CT and PET/MR, within a multimodality imaging framework both in clinical practice and in clinical trials for 4Is cardiovascular indications.
  •  
10.
  • Slart, Riemer H J A, et al. (författare)
  • Procedural recommendations of cardiac PET/CT imaging : standardization in inflammatory-, infective-, infiltrative-, and innervation- (4Is) related cardiovascular diseases
  • 2020
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 21:12, s. 1320-1330
  • Tidskriftsartikel (refereegranskat)abstract
    • With this summarized document we share the standard for positron emission tomography (PET)/(diagnostic)computed tomography (CT) imaging procedures in cardiovascular diseases that are inflammatory, infective, infiltrative, or associated with dysfunctional innervation (4Is) as recently published in the European Journal of Nuclear Medicine and Molecular Imaging. This standard should be applied in clinical practice and integrated in clinical (multicentre) trials for optimal standardization of the procedurals and interpretations. A major focus is put on procedures using [18F]-2-fluoro-2-deoxyglucose ([18F]FDG), but 4Is PET radiopharmaceuticals beyond [18F]FDG are also described in this summarized document. Whilst these novel tracers are currently mainly applied in early clinical trials, some multicentre trials are underway and we foresee in the near future their use in clinical care and inclusion in the clinical guidelines. Diagnosis and management of 4Is related cardiovascular diseases are generally complex and often require a multidisciplinary approach by a team of experts. The new standards described herein should be applied when using PET/CT and PET/magnetic resonance, within a multimodality imaging framework both in clinical practice and in clinical trials for 4Is cardiovascular indications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy