SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Scandurra M.) "

Sökning: WFRF:(Scandurra M.)

  • Resultat 1-10 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abat, E., et al. (författare)
  • The ATLAS Transition Radiation Tracker (TRT) proportional drift tube: design and performance
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:2
  • Tidskriftsartikel (refereegranskat)abstract
    • A straw proportional counter is the basic element of the ATLAS Transition Radiation Tracker (TRT). Its detailed properties as well as the main properties of a few TRT operating gas mixtures are described. Particular attention is paid to straw tube performance in high radiation conditions and to its operational stability.
  •  
2.
  • Abat, E., et al. (författare)
  • The ATLAS TRT electronics
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:6
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS inner detector consists of three sub-systems: the pixel detector spanning the radius range 4cm-20cm, the semiconductor tracker at radii from 30 to 52 cm, and the transition radiation tracker (TRT), tracking from 56 to 107 cm. The TRT provides a combination of continuous tracking with many projective measurements based on individual drift tubes (or straws) and of electron identification based on transition radiation from fibres or foils interleaved between the straws themselves. This paper describes the on and off detector electronics for the TRT as well as the TRT portion of the data acquisition (DAQ) system.
  •  
3.
  • Abat, E., et al. (författare)
  • The ATLAS TRT end-cap detectors
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS TRT end-cap is a tracking drift chamber using 245,760 individual tubular drift tubes. It is a part of the TRT tracker which consist of the barrel and two end-caps. The TRT end-caps cover the forward and backward pseudo-rapidity region 1.0 < vertical bar eta vertical bar < 2.0, while the TRT barrel central eta region vertical bar eta vertical bar < 1.0. The TRT system provides a combination of continuous tracking with many measurements in individual drift tubes ( or straws) and of electron identification based on transition radiation from fibers or foils interleaved between the straws themselves. Along with other two sub-systems, namely the Pixel detector and Semi Conductor Tracker (SCT), the TRT constitutes the ATLAS Inner Detector. This paper describes the recently completed and installed TRT end-cap detectors, their design, assembly, integration and the acceptance tests applied during the construction.
  •  
4.
  • Abat, E., et al. (författare)
  • The ATLAS TRT barrel detector
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS TRT barrel is a tracking drift chamber using 52,544 individual tubular drift tubes. It is one part of the ATLAS Inner Detector, which consists of three sub-systems: the pixel detector spanning the radius range 4 to 20 cm, the semiconductor tracker (SCT) from 30 to 52 cm, and the transition radiation tracker ( TRT) from 56 to 108 cm. The TRT barrel covers the central pseudo-rapidity region |eta| < 1, while the TRT endcaps cover the forward and backward eta regions. These TRT systems provide a combination of continuous tracking with many measurements in individual drift tubes ( or straws) and of electron identification based on transition radiation from fibers or foils interleaved between the straws themselves. This paper describes the recently-completed construction of the TRT Barrel detector, including the quality control procedures used in the fabrication of the detector.
  •  
5.
  • Tillmann, J., et al. (författare)
  • Evaluating Sex and Age Differences in ADI-R and ADOS Scores in a Large European Multi-site Sample of Individuals with Autism Spectrum Disorder
  • 2018
  • Ingår i: Journal of Autism and Developmental Disorders. - : Springer Science and Business Media LLC. - 0162-3257 .- 1573-3432. ; 48:7, s. 2490-2505
  • Tidskriftsartikel (refereegranskat)abstract
    • Research on sex-related differences in Autism Spectrum Disorder (ASD) has been impeded by small samples. We pooled 28 datasets from 18 sites across nine European countries to examine sex differences in the ASD phenotype on the ADI-R (376 females, 1763 males) and ADOS (233 females, 1187 males). On the ADI-R, early childhood restricted and repetitive behaviours were lower in females than males, alongside comparable levels of social interaction and communication difficulties in females and males. Current ADI-R and ADOS scores showed no sex differences for ASD severity. There were lower socio-communicative symptoms in older compared to younger individuals. This large European ASD sample adds to the literature on sex and age variations of ASD symptomatology.
  •  
6.
  •  
7.
  •  
8.
  • Echeverria, N. I., et al. (författare)
  • Análisis de la fotopletismografía para determinación de variaciones en el tono vascular y la presión arterial : Estudio basado en redes neuronales [Photoplethysmography waveform analysis for classification of vascular tone andarterial blood pressure: Study based on neural networks]
  • 2023
  • Ingår i: REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION. - : Elsevier BV. - 0034-9356 .- 2340-3284. ; 70:4, s. 209-217
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To test whether a Shallow Neural Network (S-NN) can detect and classify vasculartone dependent changes in arterial blood pressure (ABP) by advanced photopletysmographic(PPG) waveform analysis.Methods: PPG and invasive ABP signals were recorded in 26 patients undergoing scheduled general surgery. We studied the occurrence of episodes of hypertension (systolic arterial pressure(SAP) > 140 mmHg), normotension and hypotension (SAP < 90 mmHg). Vascular tone accordingto PPG was classified in two ways: 1) By visual inspection of changes in PPG waveform amplitude and dichrotic notch position; where Classes I-II represent vasoconstriction (notch placed> 50% of PPG amplitude in small amplitude waves), Class III normal vascular tone (notch placedbetween 20-50% of PPG amplitude in normal waves) and Classes IV-V-VI vasodilation (notch <20% of PPG amplitude in large waves). 2) By an automated analysis, using S-NN trained andvalidated system that combines seven PPG derived parameters.Results: The visual assessment was precise in detecting hypotension (sensitivity 91%, specificity86% and accuracy 88%) and hypertension (sensitivity 93%, specificity 88% and accuracy 90%). Normotension presented as a visual Class III (III-III) (median and 1st-3rdquartiles), hypotensionas a Class V (IV-VI) and hypertension as a Class II (I-III); all p < 0.0001. The automated S-NNperformed well in classifying ABP conditions. The percentage of data with correct classificationby S-ANN was 83% for normotension, 94% for hypotension, and 90% for hypertension.Conclusions: Changes in ABP were correctly classified automatically by S-NN analysis of the PPGwaveform contour.
  •  
9.
  • Fagerlund, A. J., et al. (författare)
  • Experiences from patients in mental healthcare accessing their electronic health records : Results from a cross-national survey in Estonia, Finland, Norway, and Sweden
  • 2024
  • Ingår i: BMC Psychiatry. - : BioMed Central (BMC). - 1471-244X. ; 24:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Patients’ online record access (ORA) enables patients to read and use their health data through online digital solutions. One such solution, patient-accessible electronic health records (PAEHRs) have been implemented in Estonia, Finland, Norway, and Sweden. While accumulated research has pointed to many potential benefits of ORA, its application in mental healthcare (MHC) continues to be contested. The present study aimed to describe MHC users’ overall experiences with national PAEHR services. Methods: The study analysed the MHC-part of the NORDeHEALTH 2022 Patient Survey, a large-scale multi-country survey. The survey consisted of 45 questions, including demographic variables and questions related to users’ experiences with ORA. We focused on the questions concerning positive experiences (benefits), negative experiences (errors, omissions, offence), and breaches of security and privacy. Participants were included in this analysis if they reported receiving mental healthcare within the past two years. Descriptive statistics were used to summarise data, and percentages were calculated on available data. Results: 6,157 respondents were included. In line with previous research, almost half (45%) reported very positive experiences with ORA. A majority in each country also reported improved trust (at least 69%) and communication (at least 71%) with healthcare providers. One-third (29.5%) reported very negative experiences with ORA. In total, half of the respondents (47.9%) found errors and a third (35.5%) found omissions in their medical documentation. One-third (34.8%) of all respondents also reported being offended by the content. When errors or omissions were identified, about half (46.5%) reported that they took no action. There seems to be differences in how patients experience errors, omissions, and missing information between the countries. A small proportion reported instances where family or others demanded access to their records (3.1%), and about one in ten (10.7%) noted that unauthorised individuals had seen their health information. Conclusions: Overall, MHC patients reported more positive experiences than negative, but a large portion of respondents reported problems with the content of the PAEHR. Further research on best practice in implementation of ORA in MHC is therefore needed, to ensure that all patients may reap the benefits while limiting potential negative consequences.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy