SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Schantz Peter 1954 )
 

Sökning: WFRF:(Schantz Peter 1954 ) > Gullstrand Lennart > Evaluation of the O...

Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method

Rosdahl, Hans (författare)
Gymnastik- och idrottshögskolan,Laboratoriet för tillämpad idrottsvetenskap (LTIV),FoU-gruppen för rörelse, hälsa och miljö,Laboratoriet för biomekanik och motorisk kontroll (BMC)
Gullstrand, Lennart (författare)
Salier Eriksson, Jane (författare)
Gymnastik- och idrottshögskolan,FoU-gruppen för rörelse, hälsa och miljö
visa fler...
Johansson, Patrik (författare)
Gymnastik- och idrottshögskolan,Björn Ekbloms forskningsgrupp
Schantz, Peter, 1954- (författare)
Gymnastik- och idrottshögskolan,Mittuniversitetet,Institutionen för hälsovetenskap (-2013),FoU-gruppen för rörelse, hälsa och miljö,Department of Health Sciences, Mid Sweden University, Östersund Sweden
visa färre...
 (creator_code:org_t)
2009-12-31
2010
Engelska.
Ingår i: European Journal of Applied Physiology. - : Springer Science and Business Media LLC. - 1439-6319 .- 1439-6327. ; 109:2, s. 159-171
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to evaluate two versions of the Oxycon Mobile portable metabolic system, (OMPS1 and OMPS2) in a wide range of oxygen uptake, using the Douglas bag method (DBM) as criterion method. The metabolic variables VO2, VCO2, respiratory exchange ratio and VE were measured during submaximal and maximal cycle ergometer exercise with sedentary, moderately trained individuals and athletes as participants. Test-retest reliability was investigated using the OMPS1. The coefficients of variation varied between 2% and 7% for the metabolic parameters measured at different work rates, and resembled those obtained with the DBM. With the OMPS1, systematic errors were found in the determination of VO2 and VCO2. At submaximal work rates VO2 was 6-14% and VCO2 5-9% higher than with the DBM. At VO2max both VO2 and VCO2 were slightly lower as compared to DBM (-4.1% and -2.8% respectively). With OMPS2, VO2 was determined accurately within a wide measurement range (about 1-5.5 L*min-1), while VCO2 was overestimated (3-7%). VE was accurate at submaximal work rates with both OMPS1 and OMPS2, whereas underestimations (4-8%) were noted at VO2max. The present study is the first to demonstrate that a wide range of VO2 can be measured accurately with the Oxycon Mobile portable metabolic system (second generation). Future investigations are suggested to clarify reasons for the small errors noted for VE and VCO2 versus the Douglas bag measurements, and also to gain knowledge of the performance of the device under applied and non-laboratory conditions.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Nyckelord

Oxygen consumption
Ventilation
Carbon dioxide production
Validity
Reliability
Oxycon Mobile
Sports
Idrott
MEDICINE
Medicin/Teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy