SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Scott Caroline) ;lar1:(kth)"

Sökning: WFRF:(Scott Caroline) > Kungliga Tekniska Högskolan

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Loza, M. J., et al. (författare)
  • Validated and longitudinally stable asthma phenotypes based on cluster analysis of the ADEPT study
  • 2016
  • Ingår i: Respiratory Research. - : Springer Nature. - 1465-9921 .- 1465-993X. ; 17:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Asthma is a disease of varying severity and differing disease mechanisms. To date, studies aimed at stratifying asthma into clinically useful phenotypes have produced a number of phenotypes that have yet to be assessed for stability and to be validated in independent cohorts. The aim of this study was to define and validate, for the first time ever, clinically driven asthma phenotypes using two independent, severe asthma cohorts: ADEPT and U-BIOPRED. Methods: Fuzzy partition-around-medoid clustering was performed on pre-specified data from the ADEPT participants (n = 156) and independently on data from a subset of U-BIOPRED asthma participants (n = 82) for whom the same variables were available. Models for cluster classification probabilities were derived and applied to the 12-month longitudinal ADEPT data and to a larger subset of the U-BIOPRED asthma dataset (n = 397). High and low type-2 inflammation phenotypes were defined as high or low Th2 activity, indicated by endobronchial biopsies gene expression changes downstream of IL-4 or IL-13. Results: Four phenotypes were identified in the ADEPT (training) cohort, with distinct clinical and biomarker profiles. Phenotype 1 was "mild, good lung function, early onset", with a low-inflammatory, predominantly Type-2, phenotype. Phenotype 2 had a "moderate, hyper-responsive, eosinophilic" phenotype, with moderate asthma control, mild airflow obstruction and predominant Type-2 inflammation. Phenotype 3 had a "mixed severity, predominantly fixed obstructive, non-eosinophilic and neutrophilic" phenotype, with moderate asthma control and low Type-2 inflammation. Phenotype 4 had a "severe uncontrolled, severe reversible obstruction, mixed granulocytic" phenotype, with moderate Type-2 inflammation. These phenotypes had good longitudinal stability in the ADEPT cohort. They were reproduced and demonstrated high classification probability in two subsets of the U-BIOPRED asthma cohort. Conclusions: Focusing on the biology of the four clinical independently-validated easy-to-assess ADEPT asthma phenotypes will help understanding the unmet need and will aid in developing tailored therapies. Trial registration:NCT01274507(ADEPT), registered October 28, 2010 and NCT01982162(U-BIOPRED), registered October 30, 2013.
  •  
2.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
3.
  • Nilsson, Caroline, et al. (författare)
  • Does early EBV infection protect against IgE sensitization?
  • 2005
  • Ingår i: Journal of Allergy and Clinical Immunology. - : Elsevier BV. - 0091-6749 .- 1097-6825. ; 116:2, s. 438-444
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: There is indirect evidence that an increased infectious burden is associated with a decreased prevalence of IgE-mediated allergy during childhood. Objective: To determine whether there is a relation between the serostatus of 13 different viruses and parentally reported infections and IgE sensitization in 2-year-old children. To investigate whether there is an interaction between cytomegalovirus (CMV) and Epstein-Barr virus (EBV) in relation to IgE sensitization. Methods: A total of 246 infants were followed prospectively to 2 years of age with clinical examinations, skin prick test, and specific IgE analyses and through analysis of seropositivity against adenovirus, influenza, parainfluenza, respiratory syncytial virus, CMV, EBV, herpes simplex virus, human herpesvirus 6, and varicella-zoster virus. Results: There was some evidence that IgE sensitization (24%) tended to be more common among children who were seropositive against few compared with children who were seropositive against many viruses, but this was not statistically significant, and there was no consistent trend across the groups. IgE sensitization was statistically significantly less prevalent at 2 years of age among infants who were seropositive against EBV but not other viruses (adjusted odds ratio, 0.34; 95% CI, 0.14-0.86). The interaction of seropositivity against both CMV and EBV antibodies indicated a further reduction in the risk for IgE sensitization (adjusted odds ratio for interaction, 0.10; 95% CI, 0.01-0.92), indicating effect modification associated with seropositivity against CMV. Conclusion: Our results indicate that acquisition of EBV infection during the first 2 years of life is associated with a reduced risk of IgE sensitization, and this effect is enhanced by CMV coinfection.
  •  
4.
  • Yamada, Shinya, et al. (författare)
  • Poisson vs. Gaussian statistics for sparse X-ray data : Application to the soft X-ray spectrometer
  • 2019
  • Ingår i: Publications of the Astronomical Society of Japan. - : OXFORD UNIV PRESS. - 0004-6264 .- 2053-051X. ; 71:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard chi(2) method and maximum likelihood based on Poisson studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn K alpha calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the chi(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of similar to 5eV and a line with about 100 photons, the line width becomes similar to 10% lower in the chi(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy