SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Shahgaldi Kambiz) ;pers:(Willenheimer Ronnie)"

Sökning: WFRF:(Shahgaldi Kambiz) > Willenheimer Ronnie

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gudmundsson, Petri, et al. (författare)
  • Head to head comparisons of two modalities of perfusion adenosine stress echocardiography with simultaneous SPECT
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : BioMed Central. - 1476-7120. ; 7:19
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Real-time perfusion (RTP) contrast echocardiography can be used during adenosine stress echocardiography (ASE) to evaluate myocardial ischemia. We compared two different types of RTP power modulation techniques, angiomode (AM) and high-resolution grayscale (HR), with 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia. Methods: Patients with known or suspected coronary artery disease (CAD), admitted to SPECT, were prospectively invited to participate. Patients underwent RTP imaging (SONOS 5500) using AM and HR during Sonovue® infusion, before and throughout the adenosine stress, also used for SPECT. Analysis of myocardial perfusion and wall motion by RTP-ASE were done for AM and HR at different time points, blinded to one another and to SPECT. Each segment was attributed to one of the three main coronary vessel areas of interest. Results: In 50 patients, 150 coronary areas were analyzed by SPECT and RTP-ASE AM and HR. SPECT showed evidence of ischemia in 13 out of 50 patients. There was no significant difference between AM and HR in detecting ischemia (p = 0.08). The agreement for AM and HR, compared to SPECT, was 93% and 96%, with Kappa values of 0.67 and 0.75, respectively (p < 0.001). Conclusion: There was no significant difference between AM and HR in correctly detecting myocardial ischemia as judged by SPECT. This suggests that different types of RTP modalities give comparable data during RTP-ASE in patients with known or suspected CAD.
  •  
2.
  •  
3.
  • Gudmundsson, Petri, et al. (författare)
  • Parametric quantification of myocardial ischaemia using real-time perfusion adenosine stress echocardiography images, with SPECT as reference method
  • 2010
  • Ingår i: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 30:1, s. 30-42
  • Tidskriftsartikel (refereegranskat)abstract
    • SUMMARY BACKGROUND: Real-time perfusion (RTP) adenosine stress echocardiography (ASE) can be used to visually evaluate myocardial ischaemia. The RTP power modulation technique, provides images for off-line parametric perfusion quantification using Qontrast software. From replenishment curves, this generates parametric images of peak signal intensity (A), myocardial blood flow velocity (beta) and myocardial blood flow (Axbeta) at rest and stress. This may be a tool for objective myocardial ischaemia evaluation. We assessed myocardial ischaemia by RTP-ASE Qontrast((R))-generated images, using 99mTc-tetrofosmin single-photon emission computed tomography (SPECT) as reference. METHODS: Sixty-seven patients admitted to SPECT underwent RTP-ASE (SONOS 5500) during Sonovue infusion, before and throughout adenosine stress, also used for SPECT. Quantitative off-line analyses of myocardial perfusion by RTP-ASE Qontrast-generated A, beta and Axbeta images, at different time points during rest and stress, were blindly compared to SPECT. RESULTS: We analysed 201 coronary territories [corresponding to the left anterior descendent (LAD), left circumflex (LCx) and right coronary (RCA) arteries] from 67 patients. SPECT showed ischaemia in 18 patients. Receiver operator characteristics and kappa values showed that A, beta and Axbeta image interpretation significantly identified ischaemia in all territories (area under the curve 0.66-0.80, P = 0.001-0.05). Combined A, beta and Axbeta image interpretation gave the best results and the closest agreement was seen in the LAD territory: 89% accuracy; kappa 0.63; P<0.001. CONCLUSION: Myocardial isachemia can be evaluated in the LAD territory using RTP-ASE Qontrast-generated images, especially by combined A, beta and Axbeta image interpretation. However, the technique needs improvements regarding the LCx and RCA territories.
  •  
4.
  •  
5.
  •  
6.
  • Gudmundsson, Petri, et al. (författare)
  • Quantitative detection of myocardial ischaemia by stress echocardiography; a comparison with SPECT
  • 2009
  • Ingår i: Cardiovascular Ultrasound. - : BioMed Central. - 1476-7120. ; 7:28
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: Real-time perfusion (RTP) adenosine stress echocardiography (ASE) can be used to visually evaluate myocardial ischaemia. The RTP power modulation technique angio-mode (AM), provides images for off-line perfusion quantification using Qontrast® software, generating values of peak signal intensity (A), myocardial blood flow velocity (β) and myocardial blood flow (Axβ). By comparing rest and stress values, their respective reserve values (A-r, β-r, Axβ-r) are generated. We evaluated myocardial ischaemia by RTP-ASE Qontrast® quantification, compared to visual perfusion evaluation with 99mTc-tetrofosmin singlephoton emission computed tomography (SPECT). Methods and Results: Patients admitted to SPECT underwent RTP-ASE (SONOS 5500) using AM during Sonovue® infusion, before and throughout adenosine stress, also used for SPECT. Visual myocardial perfusion and wall motion analysis, and Qontrast® quantification, were blindly compared to one another and to SPECT, at different time points off-line. We analyzed 201 coronary territories (left anterior descendent [LAD], left circumflex [LCx] and right coronary [RCA] artery territories) in 67 patients. SPECT showed ischaemia in 18 patients and 19 territories. Receiver operator characteristics and kappa values showed significant agreement with SPECT only for β-r and Axβ-r in all segments: area under the curve 0.678 and 0.665; P < 0.001 and < 0.01, respectively. The closest agreements were seen in the LAD territory: kappa 0.442 for both β-r and Axβ- r; P < 0.01. Visual evaluation of ischaemia showed good agreement with SPECT: accuracy 93%; kappa 0.67; P < 0.001; without non-interpretable territories. Conclusion: In this agreement study with SPECT, RTP-ASE Qontrast® quantification of myocardial ischaemia was less accurate and less feasible than visual evaluation and needs further development to be clinically useful.
  •  
7.
  • Ostenfeld, Ellen, et al. (författare)
  • Comparison of different views with three-dimensional echocardiography : apical views offer superior visualization compared with parasternal and subcostal views
  • 2008
  • Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961 .- 1475-097X. ; 28:6, s. 409-416
  • Tidskriftsartikel (refereegranskat)abstract
    • Studies seeking to validate real-time three-dimensional echocardiography (3DE) with regard to cardiac function and dimensions have almost exclusively used apical views. However, it has never been examined whether apical views are preferable to parasternal or subcostal views. In the present study, we compared the feasibility of 3DE volumetric measurements of the four heart chambers in three different views. We included 40 patients planned for a routine two-dimensional transthoracic echocardiography examination (2DE). All patients were scanned with both 2DE and 3DE (Sonos 7500; Philips Medical Systems Andover, MA, USA). Parasternal, apical and subcostal views were used for 3DE. Volumes were calculated using manual tracing in 16 planes. 2DE was performed in parasternal longaxis, subcostal and apical four- and two-chamber views. Manual tracing was used for area calculations. To be judged fully traceable, 5/6 (85%) or more of the ventricular and atrial walls had to be adequately visualized in each plane. The left ventricle and left atrium were adequately visualized in the 3DE apical view in 34 (85%) and 40 (100%) patients, respectively. Visualization of the right atrium was adequate in 31 (78%) patients, whereas the right ventricle was adequately visualized in only 12 (30%) patients. The apical view of 3DE provided superior visualization of all four heart chambers compared with the parasternal and subcostal views, when applying a slight off-axis approach for both ventricles when needed. Thus, in the present study, there was no incremental value of assessment of chamber volumes in the parasternal and subcostal views.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy