SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Shahgaldi Kambiz) ;pers:(da Silva Cristina)"

Sökning: WFRF:(Shahgaldi Kambiz) > Da Silva Cristina

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • da Silva, Cristina, et al. (författare)
  • Hemodynamic outcomes of transcatheter aortic valve implantation with the CoreValve system : an early assessment
  • 2015
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 35:3, s. 216-222
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and Aims: Transcatheter aortic valve implantation (TAVI) is an established method for the treatment of high-risk patients with aortic stenosis (AS). The beneficial effects of TAVI in cardiac hemodynamics have been described in recent studies, but those investigations were mostly performed after an interval of more than 6 months following aortic valve implantation. The aim of this study is to investigate the acute and short-term alterations in hemodynamic conditions using the echocardiography outcomes in patients undergoing TAVI. Methods and Results: A total of 60 patients (26 males, 34 females; age 84·7 ± 5·8) who underwent TAVI with CoreValve system were included in the study. Echocardiography was performed before hospital discharge and at 3 months follow-up. As expected, TAVI was associated with an immediate significant improvement in aortic valve area (AVA) (from 0·64 ± 0·16 cm2 to 1·67 ± 0·41 cm2, P-value<0·001) and mean gradient (from 51·9 ± 15·4 mmHg to 8·8 ± 3·8 mmHg, P-value<0·001). At 3-month follow-up, systolic LV function was augmented (EF: 50 ± 14% to 54 ± 11%, P-value = 0·024). Left ventricle (LV) mass and left atrium (LA) volume were significantly reduced (LV mass index from 126·5 ± 30·5 g m-2 to 102·4 ± 32·4 g m-2; LA index from 42·9 ± 17·3 ml m-2 to 33·6 ± 10·6 ml m-2; P-value<0·001 for both). Furthermore, a decrement in systolic pulmonary artery pressure (SPAP) from 47·5 ± 13·5 mmHg to 42·5 ± 11·2 mmHg, P-value = 0·02 was also observed. Despite the high incidence of paravalvular regurgitation (PVR) (80%), most of the patients presented mild or trace PVR and no significant progress of the regurgitation grade was seen after 3 months. Conclusion: This study demonstrates that the beneficial effects of TAVI in cardiac function and hemodynamics occur already after a short period following aortic valve implantation.
  •  
2.
  • da Silva, Cristina, et al. (författare)
  • Prosthesis-patient mismatch after transcatheter aortic valve implantation : impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography
  • 2014
  • Ingår i: The International Journal of Cardiovascular Imaging. - : Springer Science and Business Media LLC. - 1569-5794 .- 1875-8312 .- 1573-0743. ; 30:8, s. 1549-1557
  • Tidskriftsartikel (refereegranskat)abstract
    • To investigate the role of 2D-transthoracic echocardiography (2D-TTE) and 3D-transesophageal echocardiography (3D-TEE) in the determination of aortic annulus size prior transcatheter aortic valve implantation (TAVI) and its' impact on the prevalence of patient prosthesis mismatch (PPM). Echocardiography plays an important role in measuring aortic annulus dimension in patients undergoing TAVI. This has great importance since it determines both eligibility for TAVI and selection of prosthesis type and size, and can be potentially important in preventing an inadequate ratio between the prosthetic valvular orifice and the patient's body surface area, concept known as prosthesis-patient mismatch (PPM). A total of 45 patients were studied pre-TAVI: 20 underwent 3D-TEE (men/women 12/8, age 84.8 +/- A 5.6) and 25 2D-TTE (men/women 9/16, age 84.4 +/- A 5.4) in order to measure aortic annulus diameter. The presence of PPM was assessed before hospital discharge and after a mean period of 3 months. Moderate PPM was defined as indexed aortic valve area (AVAi) a parts per thousand currency sign 0.85 cm(2)/m(2) and severe PPM as AVAi < 0.65 cm(2)/m(2). Immediately post-TAVI, moderate PPM was present in 25 and 28 % of patients worked up using 3D-TEE and 2D-TTE respectively p value = n.s) and severe PPM occurred in 10 % of the patients who underwent 3D-TEE and in 20 % in those with 2D-TTE (p value = n.s). The echocardiographic evaluation 3 months post-TAVI showed 25 % moderate PPM in the 3D-TEE group compared with 24 % in the 2D-TTE group (p value = n.s) and no cases of severe PPM in the 3DTEE group comparing to 20 % in the 2D-TTE group (p = 0.032). Our results indicate a higher incidence of severe PPM in patients who performed 2DTTE compared to those performing 3DTEE prior TAVI. This suggests that the 3D technique should replace the 2DTTE analysis when investigating the aortic annulus diameter in patients undergoing TAVI.
  •  
3.
  • Shahgaldi, Kambiz, et al. (författare)
  • Transesophageal echocardiography measurements of aortic annulus diameter using biplane mode in patients undergoing transcatheter aortic valve implantation
  • 2013
  • Ingår i: Cardiovascular Ultrasound. - : Springer Science and Business Media LLC. - 1476-7120. ; 11:1, s. 5-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Aortic stenosis (AS) is a relevant common valve disorder. Severe AS and symptoms and/or left ventricular dysfunction (EF<50%) have the indication for aortic valve replacement (AVR). Majority of the patients with AS are elderly often with co-morbidities and generally have high preoperative risk. Transcatheter aortic valve implantation (TAVI) is offered in this group. Four different sizes of Corevalve prosthesis are available. Correct measurement of aortic size prior to TAVI is of great important to choose the right prosthesis size to avoid among others paravalvular leak or prosthesis patient mismatch. Aim of the study is to assess the aortic annulus diameter in patients undergoing TAVI by biplane (BP) mode using transesophageal echocardiography (TEE) and compare it to two-dimensional (2D) transthoracic echocardiography (TTE) and 2DTEE using three-dimensional (3D) TEE as reference method. Methods: The study population consisted of 50 patients retrospectively (24 men and 26 women, mean age 85 +/- 8 years of age) who all had undergone echocardiography examination prior to TAVI. Results: The mean aortic annulus diameter was 20.4 +/- 2.2 mm with TTE, 22.3 +/- 2.5 mm with 2DTEE, 22.9 +/- 1.9 mm with BP-mode and 23.1 +/- 1.9 mm with 3DTEE. TTE underestimated the mean aortic annulus diameter in comparison to transesophageal imaging modalities (p<0.001). Using 3DTEE, 2% of patients were unsuitable for TAVI due to a too-small AoA (n=1). This figure was similar with BP (4%, n=2; p=1.00) but considerably larger with 2DTTE (36%, n=18; p<0.001) and 2DTEE (12%, n=6; p=0.06). There was a strong correlation between BP-mode and 3DTEE for assessment of aortic annulus diameter (r-value 0.88) with small mean difference (-0.2 +/- 0.9 mm) whereas the other modalities showed larger 95% confidence interval and modest correlation (2DTTE vs. 3DTEE, -6.3 to 0.9 mm, r=0.64 and 2DTEE vs. 3DTEE, -4.8 to 3.2 mm, r=0.61). Conclusion: A multi-dimensional method is preferred to assess aortic annulus diameter in TAVI patients since there is risk of underestimation using single plane. Biplane mode is the method of choice in view of speedy post-processing with no need for expensive dedicated software. Lastly, single plane methods lead to misclassification of patients as unsuitable for TAVI. This may be of major clinical importance.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3
Typ av publikation
tidskriftsartikel (3)
Typ av innehåll
refereegranskat (3)
Författare/redaktör
Sahlén, Anders (3)
Rück, Andreas (3)
Shahgaldi, Kambiz (3)
Manouras, Aristomeni ... (3)
Bäck, Magnus (2)
visa fler...
Settergren, Magnus (2)
Winter, Reidar (2)
Back, Magnus (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (3)
Karolinska Institutet (3)
Språk
Engelska (3)
Forskningsämne (UKÄ/SCB)
Teknik (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy