SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Strand Sven Erik) ;pers:(Fredriksson Sarah)"

Sökning: WFRF:(Strand Sven Erik) > Fredriksson Sarah

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Evertsson, Maria, et al. (författare)
  • Combined Magnetomotive ultrasound, PET/CT, and MR imaging of (68)Ga-labelled superparamagnetic iron oxide nanoparticles in rat sentinel lymph nodes in vivo
  • 2017
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Current methods for intra-surgical guidance to localize metastases at cancer surgery are based on radioactive tracers that cause logistical challenges. We propose the use of a novel ultrasound-based method, magnetomotive ultrasound (MMUS) imaging that employ a nanoparticle-based contrast agent that also may be used for pre-operative PET/MRI imaging. Since MMUS is radiation free, this eliminates the dependence between pre- and intra-operative imaging and the radiation exposure for the surgical staff. This study investigates a hypothetical clinical scenario of pre-operative PET imaging, combined with intra-operative MMUS imaging, implemented in a sentinel lymph node (SLN) rat model. At one-hour post injection of (68)Ga-labelled magnetic nanoparticles, six animals were imaged with combined PET/CT. After two or four days, the same animals were imaged with MMUS. In addition, ex-vivo MRI was used to evaluate the amount of nanoparticles in each single SLN. All SLNs were detectable by PET. Four out of six SLNs could be detected with MMUS, and for these MMUS and MRI measurements were in close agreement. The MRI measurements revealed that the two SLNs undetectable with MMUS contained the lowest nanoparticle concentrations. This study shows that MMUS can complement standard pre-operative imaging by providing bedside real-time images with high spatial resolution.
  •  
2.
  •  
3.
  • Kjellman, Pontus, et al. (författare)
  • Optimizing retention of multimodal imaging nanostructures in sentinel lymph nodes by nanoscale size tailoring.
  • 2014
  • Ingår i: Nanomedicine: Nanotechnology, Biology and Medicine. - : Elsevier BV. - 1549-9642 .- 1549-9634. ; 10:5, s. 1089-1095
  • Tidskriftsartikel (refereegranskat)abstract
    • This study investigates the retention of different sized ultra-small superparamagnetic iron oxide nanoparticles (USPIOs) in lymph nodes of healthy rats, after subcutaneous injection. Three distinct sizes (15, 27 and 58 nm) of USPIOs were synthesized by only varying the thickness of the polymer coating surrounding the 10 nm cores. Particles were injected on the dorsal side of the hind paw of rats and the uptake in the popliteal, inguinal and iliac lymph nodes was monitored. The data reveal that the 15 nm particle accumulates more rapidly and to a higher amount in the first lymph node than the two larger particles. A clear contrast between the first and second lymph nodes could be detected indicating that even the rather small difference in particle size (15-58 nm) tested has significant effects on the retention of USPIOs in the lymph nodes.
  •  
4.
  • Kjellman, Pontus, et al. (författare)
  • Size-dependent lymphatic uptake of nanoscale-tailored particles as tumor mass increases
  • 2015
  • Ingår i: Future science OA. - : Future Science Ltd. - 2056-5623. ; 1:4
  • Tidskriftsartikel (refereegranskat)abstract
    • AIM: To investigate the size-dependent lymphatic uptake of nanoparticles in mice with rapidly growing syngeneic tumors.MATERIALS & METHODS: Mice were inoculated subcutaneously with EL4 lymphoma cells and on day 5 or day 6 of tumor growth, injected peritumorally with either 29 nm or 58 nm of ultra-small superparamagnetic iron oxide nanoparticles. Twenty-four hours later the animals were imaged using MRI.RESULTS & CONCLUSION: The larger of the two particles can only be detected in the lymph node when injected in animals with 6-day-old tumors while the 29 nm ultra-small superparamagnetic iron oxide nanoparticle is observed on both time points. Tumor mass greatly impacts the size of particles that are transported to the lymph nodes.
  •  
5.
  • Madru, Renata, et al. (författare)
  • 99mTc-Labeled Superparamagnetic Iron Oxide Nanoparticles for Multimodality SPECT/MRI of Sentinel Lymph Nodes.
  • 2012
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 2159-662X. ; 53:3, s. 459-463
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study was to develop multimodality SPECT/MRI contrast agents for sentinel lymph node (SLN) mapping in vivo. METHODS: Nanoparticles with a solid iron oxide core and a polyethylene glycol coating were labeled with (99m)Tc. The labeling efficiency was determined with instant thin-layer chromatography and magnetic separation. The stability of the radiolabeled superparamagnetic iron oxide nanoparticles (SPIONs) was verified in both sterile water and human serum at room temperature 6 and 24 h after labeling. Five Wistar rats were injected subcutaneously in the right hind paw with (99m)Tc-SPIONs (25-50 MBq, ∼0.2 mg of Fe) and sacrificed 4 h after injection. Two animals were imaged with SPECT/MRI. All 5 rats were dissected; the lymph nodes, liver, kidneys, spleen, and hind paw containing the injection site were removed and weighed; and activity in the samples was measured. The microdistribution within the lymph nodes was studied with digital autoradiography. RESULTS: The efficiency of labeling of the SPIONs was 99% 6 h after labeling in both water and human serum. The labeling yield was 98% in water and 97% in human serum 24 h after labeling. The SLN could be identified in vivo with SPECT/MRI. The accumulation of (99m)Tc-SPIONs (as the percentage injected dose/g [%ID/g]) in the SLN was 100 %ID/g, whereas in the liver and spleen it was less than 2 %ID/g. Digital autoradiography images revealed a nonhomogeneous distribution of (99m)Tc-SPIONs within the lymph nodes; nanoparticles were found in the cortical, subcapsular, and medullary sinuses. CONCLUSION: This study revealed the feasibility of labeling SPIONs with (99m)Tc. The accumulation of (99m)Tc-SPIONs in lymph nodes after subcutaneous injection in animals, verified by SPECT/MRI, is encouraging for applications in breast cancer and malignant melanoma.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy