SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Strand Sven Erik) ;pers:(Ljunggren Kaj)"

Sökning: WFRF:(Strand Sven Erik) > Ljunggren Kaj

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Reinstrup, Peter, et al. (författare)
  • Regional cerebral metabolic rate (positron emission tomography) during inhalation of nitrous oxide 50% in humans
  • 2008
  • Ingår i: British Journal of Anaesthesia. - : Elsevier BV. - 1471-6771 .- 0007-0912. ; 100:1, s. 66-71
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Recent studies in man have shown that cerebral blood flow increases during inhalation of nitrous oxide (N2O), a finding which is believed to be a result of an increased cerebral metabolic rate (CMR). However, this has not previously been evaluated in man. METHODS: Regional CMR(glu) (rCMR(glu)) was measured three dimensionally with positron emission tomography (PET) after injection of 2-(18F)fluoro-2-deoxy-D-glucose in 10 spontaneously breathing men (mean age 31 yr) inhaling either N2O 50% in O2 30% or O2 30% in N2. RESULTS: Global CMR(glu) in young men was 27 (3) micromol 100 g(-1) min(-1) [mean (SD)]. Inhalation of N2O 50% did not change global CMR(glu) [30 (5) micromol 100 g(-1) min(-1)] significantly, but it changed the distribution of the metabolism in the brain (P<0.0001 analysis of variance). Compared with inhalation of O2 30% in N2, N2O 50% inhalation increased the metabolism in the basal ganglia [14 (17)%, P<0.05] and thalamus [22 (23) %, P<0.05]. There was a prolonged metabolic effect of N2O inhalation seen on a succeeding PET scan with oxygen-enriched air (P<0.0001) performed 1 h after the N2O administration. CONCLUSIONS: Inhalation of N2O 50% did not change global CMR(glu), but the metabolism increased in central brain structures, an effect that was still present 1 h after discontinuation of N2O.
  •  
2.
  •  
3.
  •  
4.
  • Ljunggren, Kaj, et al. (författare)
  • Beta camera low activity tumor imaging
  • 1993
  • Ingår i: Acta Oncologica. - : Informa UK Limited. - 1651-226X .- 0284-186X. ; 32:7-8, s. 869-872
  • Tidskriftsartikel (refereegranskat)abstract
    • A new technique, the beta camera, to complement film autoradiography, with fast quantitative imaging of beta particle-emitting radionuclides has been developed. It consists of a thin plastic scintillator and a light-sensitive microchannel plate detector. The thin tissue sample is mounted on the scintillator. Our first system had a high background and a moderate spatial resolution of 900 microns. We now report an improved system with a photomultiplier tube mounted on the scintillator of the microchannel plate detector. Only events registered by both detectors are accepted. A fast coincidence unit processes the signals, and if a time overlap exists, an event is generated in the beta camera. In the coincidence mode, images with low activity distribution of 201Tl (count rate 1 s-1) in 50 microns-thick slices of a human glioma tumor could be recorded with a spatial resolution of 500 microns.
  •  
5.
  • Peterson, Mikael, et al. (författare)
  • Construction of a Pre-Clinical High Resolution Tomographic Scintillation Camera System
  • 2009
  • Ingår i: 2009 IEEE Nuclear Science Symposium Conference Record, Vols 1-5. - 1082-3654. ; , s. 3670-3671
  • Konferensbidrag (refereegranskat)abstract
    • We are constructing a High Resolution Tomographic Scintillation Camera System for small animal imaging. The system consists of a CsI(Tl) scintillator coupled to a military surplus image intensifier with a CCD camera focused on the output window. The system operates in photons counting mode and the spatial resolution is improved by centroid calculations for every photon interaction. The system can be mounted on an optical rail together with a pinhole collimator and a rotating table. A hot rod phantom was filled with Tl-201 or Tc-99m solute and imaged. The phantom rod diameters range from 1.1 to 1.6 mm. 64 projections were acquired (300 s/projection) with 1 mm pinhole insert. Data was reconstructed using an OSEM algorithm. Image data was corrected for decay, position non-linearities in image intensifier and the angular dependence of the pinhole. The reconstructed resolution is 13 mm (by visual inspection) for both Tc-99m and Tl-201. Higher spatial resolution is achievable with smaller pinhole diameters. Future work includes optimizing spatial resolution and sensitivity of a single system using analytical calculations, experiments and simulations. With the conclusions drawn from those calculations we plan to construct a multi-camera system.
  •  
6.
  • Sjöholm, H, et al. (författare)
  • Necrosis of malignant gliomas after intratumoral injection of 201Tl in vivo in the rat
  • 1995
  • Ingår i: Anti-Cancer Drugs. - 0959-4973. ; 6:1, s. 109-114
  • Tidskriftsartikel (refereegranskat)abstract
    • Fourteen adult Fischer 344 rats were inoculated in vivo unilaterally in the caudate nucleus in the brain with malignant RG 2 glioma cells. By 3 weeks a tumor with a diameter of 3-6 mm normally develops. Ten animals which survived the repeated periods of anesthesia and thallium (Tl) injections (intratumorally three times of 201Tl, 15-23 days after inoculation) showed a prolonged retention of radioactivity at the site of injection with no uptake in other organs except for the kidneys. Singular circumscribed necroses were found post-mortem at the site of injection, comprising malignant glioma tumor tissue, which in six animals was absent, in three animals was markedly reduced in size compared with controls and in one animal had the expected size. In four animals metastases were found in distant locations in the brain; in three of these cases there was a retention of radioactivity in the tumor. The selective necrotizing effect on the tumor cells is interpreted as mainly due to emission of Auger electrons from intracellularly accumulated 201Tl, giving rise to very high energy deposition in the vicinity of the cell nucleus. The results should also have implications for the treatment of human malignant gliomas.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy