SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sutcliffe S) ;pers:(Sutcliffe P.)"

Sökning: WFRF:(Sutcliffe S) > Sutcliffe P.

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Acharya, B. S., et al. (författare)
  • Introducing the CTA concept
  • 2013
  • Ingår i: Astroparticle physics. - : Elsevier BV. - 0927-6505 .- 1873-2852. ; 43, s. 3-18
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • The Cherenkov Telescope Array (CTA) is a new observatory for very high-energy (VHE) gamma rays. CTA has ambitions science goals, for which it is necessary to achieve full-sky coverage, to improve the sensitivity by about an order of magnitude, to span about four decades of energy, from a few tens of GeV to above 100 TeV with enhanced angular and energy resolutions over existing VHE gamma-ray observatories. An international collaboration has formed with more than 1000 members from 27 countries in Europe, Asia, Africa and North and South America. In 2010 the CTA Consortium completed a Design Study and started a three-year Preparatory Phase which leads to production readiness of CTA in 2014. In this paper we introduce the science goals and the concept of CTA, and provide an overview of the project. (C) 2013 Elsevier B.V. All rights reserved.
  •  
2.
  • Actis, M., et al. (författare)
  • Design concepts for the Cherenkov Telescope Array CTA : an advanced facility for ground-based high-energy gamma-ray astronomy
  • 2011
  • Ingår i: Experimental astronomy. - : Springer. - 0922-6435 .- 1572-9508. ; 32:3, s. 193-316
  • Tidskriftsartikel (refereegranskat)abstract
    • Ground-based gamma-ray astronomy has had a major breakthrough with the impressive results obtained using systems of imaging atmospheric Cherenkov telescopes. Ground-based gamma-ray astronomy has a huge potential in astrophysics, particle physics and cosmology. CTA is an international initiative to build the next generation instrument, with a factor of 5-10 improvement in sensitivity in the 100 GeV-10 TeV range and the extension to energies well below 100 GeV and above 100 TeV. CTA will consist of two arrays (one in the north, one in the south) for full sky coverage and will be operated as open observatory. The design of CTA is based on currently available technology. This document reports on the status and presents the major design concepts of CTA.
  •  
3.
  • Abdesselam, A., et al. (författare)
  • The ATLAS semiconductor tracker end-cap module
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 575:3, s. 353-389
  • Tidskriftsartikel (refereegranskat)abstract
    • The challenges for the tracking detector systems at the LHC are unprecedented in terms of the number of channels, the required read-out speed and the expected radiation levels. The ATLAS Semiconductor Tracker. (SCT) end-caps have a total of about 3 million electronics channels each reading out every 25 ns into its own on-chip 3.3 mu s buffer. The highest anticipated dose after 10 years operation is 1.4x10(14) cm(-2) in units of 1 MeV neutron equivalent (assuming the damage factors scale with the non-ionising energy loss). The forward tracker has 1976 double-sided modules, mostly of area similar to 70 cm(2), each having 2 x 768 strips read out by six ASICs per side. The requirement to achieve an average perpendicular radiation length of 1.5% X-0, while coping with up to 7 W dissipation per module (after irradiation), leads to stringent constraints on the thermal design. The additional requirement of 1500e(-) equivalent noise charge (ENC) rising to only 1800e(-) ENC after irradiation, provides stringent design constraints on both the high-density Cu/Polyimide flex read-out circuit and the ABCD3TA read-out ASICs. Finally, the accuracy of module assembly must not compromise the 16 mu m (r phi) resolution perpendicular to the strip directions or 580 mu m radial resolution coming from the 40 mrad front-back stereo angle. A total of 2210 modules were built to the tight tolerances and specifications required for the SCT. This was 234 more than the 1976 required and represents a yield of 93%. The component flow was at times tight, but the module production rate of 40-50 per week was maintained despite this. The distributed production was not found to be a major logistical problem and it allowed additional flexibility to take advantage of where the effort was available, including any spare capacity, for building the end-cap modules. The collaboration that produced the ATLAS SCT end-cap modules kept in close contact at all times so that the effects of shortages or stoppages at different sites could be rapidly resolved.
  •  
4.
  • Abdesselam, A., et al. (författare)
  • Engineering for the ATLAS SemiConductor Tracker (SCT) end-cap
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS SemiConductor Tracker (SCT) is a silicon-strip tracking detector which forms part of the ATLAS inner detector. The SCT is designed to track charged particles produced in proton-proton collisions at the Large Hadron Collider (LHC) at CERN at an energy of 14 TeV. The tracker is made up of a central barrel and two identical end-caps. The barrel contains 2112 silicon modules, while each end-cap contains 988 modules. The overall tracking performance depends not only on the intrinsic measurement precision of the modules but also on the characteristics of the whole assembly, in particular, the stability and the total material budget. This paper describes the engineering design and construction of the SCT end-caps, which are required to support mechanically the silicon modules, supply services to them and provide a suitable environment within the inner detector. Critical engineering choices are highlighted and innovative solutions are presented - these will be of interest to other builders of large-scale tracking detectors. The SCT end-caps will be fully connected at the start of 2008. Further commissioning will continue, to be ready for proton-proton collision data in 2008.
  •  
5.
  • Gonzalez-Sevilla, S., et al. (författare)
  • A double-sided silicon micro-strip Super-Module for the ATLAS Inner Detector upgrade in the High-Luminosity LHC
  • 2014
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 9, s. P02003-
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS experiment is a general purpose detector aiming to fully exploit the discovery potential of the Large Hadron Collider (LHC) at CERN. It is foreseen that after several years of successful data-taking, the LHC physics programme will be extended in the so-called High-Luminosity LHC, where the instantaneous luminosity will be increased up to 5 x 10(34) cm(-2) s(-1). For ATLAS, an upgrade scenario will imply the complete replacement of its internal tracker, as the existing detector will not provide the required performance due to the cumulated radiation damage and the increase in the detector occupancy. The current baseline layout for the new ATLAS tracker is an all-silicon-based detector, with pixel sensors in the inner layers and silicon micro-strip detectors at intermediate and outer radii. The super-module is an integration concept proposed for the strip region of the future ATLAS tracker, where double-sided stereo silicon micro-strip modules are assembled into a low-mass local support structure. An electrical super-module prototype for eight double-sided strip modules has been constructed. The aim is to exercise the multi-module readout chain and to investigate the noise performance of such a system. In this paper, the main components of the current super-module prototype are described and its electrical performance is presented in detail.
  •  
6.
  • Diez, S., et al. (författare)
  • A double-sided, shield-less stave prototype for the ATLAS Upgrade strip tracker for the High Luminosity LHC
  • 2014
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 9, s. P03012-
  • Tidskriftsartikel (refereegranskat)abstract
    • A detailed description of the integration structures for the barrel region of the silicon strips tracker of the ATLAS Phase-II upgrade for the upgrade of the Large Hadron Collider, the so-called High Luminosity LHC (HL-LHC), is presented. This paper focuses on one of the latest demonstrator prototypes recently assembled, with numerous unique features. It consists of a shortened, shield-less, and double sided stave, with two candidate power distributions implemented. Thermal and electrical performances of the prototype are presented, as well as a description of the assembly procedures and tools.
  •  
7.
  • Korenblik, R., et al. (författare)
  • Dragon 1 Protocol Manuscript : Training, Accreditation, Implementation and Safety Evaluation of Portal and Hepatic Vein Embolization (PVE/HVE) to Accelerate Future Liver Remnant (FLR) Hypertrophy
  • 2022
  • Ingår i: Cardiovascular and Interventional Radiology. - : Springer. - 0174-1551 .- 1432-086X. ; 45, s. 1391-1398
  • Tidskriftsartikel (refereegranskat)abstract
    • Study Purpose The DRAGON 1 trial aims to assess training, implementation, safety and feasibility of combined portal- and hepatic-vein embolization (PVE/HVE) to accelerate future liver remnant (FLR) hypertrophy in patients with borderline resectable colorectal cancer liver metastases. Methods The DRAGON 1 trial is a worldwide multicenter prospective single arm trial. The primary endpoint is a composite of the safety of PVE/HVE, 90-day mortality, and one year accrual monitoring of each participating center. Secondary endpoints include: feasibility of resection, the used PVE and HVE techniques, FLR-hypertrophy, liver function (subset of centers), overall survival, and disease-free survival. All complications after the PVE/HVE procedure are documented. Liver volumes will be measured at week 1 and if applicable at week 3 and 6 after PVE/HVE and follow-up visits will be held at 1, 3, 6, and 12 months after the resection. Results Not applicable. Conclusion DRAGON 1 is a prospective trial to assess the safety and feasibility of PVE/HVE. Participating study centers will be trained, and procedures standardized using Work Instructions (WI) to prepare for the DRAGON 2 randomized controlled trial. Outcomes should reveal the accrual potential of centers, safety profile of combined PVE/HVE and the effect of FLR-hypertrophy induction by PVE/HVE in patients with CRLM and a small FLR.
  •  
8.
  • Chen, Jeffrey, et al. (författare)
  • Robot-Assisted Versus Laparoscopic Distal Pancreatectomy in Patients with Resectable Pancreatic Cancer: An International, Retrospective, Cohort Study
  • 2023
  • Ingår i: Annals of Surgical Oncology. - : SPRINGER. - 1068-9265 .- 1534-4681. ; 30, s. 3023-3032
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundRobot-assisted distal pancreatectomy (RDP) is increasingly used as an alternative to laparoscopic distal pancreatectomy (LDP) in patients with resectable pancreatic cancer but comparative multicenter studies confirming the safety and efficacy of RDP are lacking.MethodsAn international, multicenter, retrospective, cohort study, including consecutive patients undergoing RDP and LDP for resectable pancreatic cancer in 33 experienced centers from 11 countries (2010-2019). The primary outcome was R0-resection. Secondary outcomes included lymph node yield, major complications, conversion rate, and overall survival.ResultsIn total, 542 patients after minimally invasive distal pancreatectomy were included: 103 RDP (19%) and 439 LDP (81%). The R0-resection rate was comparable (75.7% RDP vs. 69.3% LDP, p = 0.404). RDP was associated with longer operative time (290 vs. 240 min, p < 0.001), more vascular resections (7.6% vs. 2.7%, p = 0.030), lower conversion rate (4.9% vs. 17.3%, p = 0.001), more major complications (26.2% vs. 16.3%, p = 0.019), improved lymph node yield (18 vs. 16, p = 0.021), and longer hospital stay (10 vs. 8 days, p = 0.001). The 90-day mortality (1.9% vs. 0.7%, p = 0.268) and overall survival (median 28 vs. 31 months, p = 0.599) did not differ significantly between RDP and LDP, respectively.ConclusionsIn selected patients with resectable pancreatic cancer, RDP and LDP provide a comparable R0-resection rate and overall survival in experienced centers. Although the lymph node yield and conversion rate appeared favorable after RDP, LDP was associated with shorter operating time, less major complications, and shorter hospital stay. The specific benefits associated with each approach should be confirmed by multicenter, randomized trials.
  •  
9.
  •  
10.
  • Knipp, D.J., et al. (författare)
  • Ionospheric Convection Response to Slow, Strong Variations in a Northward Interplanetary Magnetic Field: A Case Study for January 14, 1988
  • 1993
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 98, s. 19273-19292
  • Tidskriftsartikel (refereegranskat)abstract
    • We analyze ionospheric convection patterns over the polar regions during the passage of an interplanetary magnetic cloud on January 14, 1988, when the interplanetary magnetic field (IMF) rotated slowly in direction and had a large amplitude. Using the assimilative mapping of ionospheric electrodynamics (AMIE) procedure, we combine simultaneous observations of ionospheric drifts and magnetic perturbations from many different instruments into consistent patterns of high-latitude electrodynamics, focusing on the period of northward IMF. By combining satellite data with ground-based observations, we have generated one of the most comprehensive data sets yet assembled and used it to produce convection maps for both hemispheres. We present evidence that a lobe convection cell was embedded within normal merging convection during a period when the IMF B(y) and B(z) components were large and positive. As the IMF became predominantly northward, a strong reversed convection pattern (afternoon-to-morning potential drop of around 100 kV) appeared in the southern (summer) polar cap, while convection in the northern (winter) hemisphere became weak and disordered with a dawn-to-dusk potential drop of the order of 30 kV. These patterns persisted for about 3 hours, until the IMF rotated significantly toward the west. We interpret this behavior in terms of a recently proposed merging model for northward IMF under solstice conditions, for which lobe field lines from the hemisphere tilted toward the Sun (summer hemisphere) drape over the dayside magnetosphere, producing reverse convection in the summer hemisphere and impeding direct contact between the solar wind and field lines connected to the winter polar cap. The positive IMF B(x) component present at this time could have contributed to the observed hemispheric asymmetry. Reverse convection in the summer hemisphere broke down rapidly after the ratio \textbackslashB(y)/B(z)\textbackslash exceeded unity, while convection in the winter hemisphere strengthened. A dominant dawn-to-dusk potential drop was established in both hemispheres when the magnitude of B(y) exceeded that of B(z), with potential drops of the order of 100 kV, even while B(z) remained northward. The later transition to southward B(z) produced a gradual intensification of the convection, but a greater qualitative change occurred at the transition through \textbackslashB(y)/B(z)\textbackslash = 1 than at the transition through B(z) = 0. The various convection patterns we derive under northward IMF conditions illustrate all possibilities previously discussed in the literature: nearly single-cell and multicell, distorted and symmetric, ordered and unordered, and sunward and antisunward.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy