SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Svensson Olof) ;srt2:(2010-2014);lar1:(gu)"

Sökning: WFRF:(Svensson Olof) > (2010-2014) > Göteborgs universitet

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Boström, Pontus, 1982, et al. (författare)
  • The SNARE protein SNAP23 and the SNARE-interacting protein Munc18c in human skeletal muscle are implicated in insulin resistance/type 2 diabetes.
  • 2010
  • Ingår i: Diabetes. - : American Diabetes Association. - 1939-327X .- 0012-1797. ; 59:8, s. 1870-8
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Our previous studies suggest that the SNARE protein synaptosomal-associated protein of 23 kDa (SNAP23) is involved in the link between increased lipid levels and insulin resistance in cardiomyocytes. The objective was to determine whether SNAP23 may also be involved in the known association between lipid accumulation in skeletal muscle and insulin resistance/type 2 diabetes in humans, as well as to identify a potential regulator of SNAP23. RESEARCH DESIGN AND METHODS: We analyzed skeletal muscle biopsies from patients with type 2 diabetes and healthy, insulin-sensitive control subjects for expression (mRNA and protein) and intracellular localization (subcellular fractionation and immunohistochemistry) of SNAP23, and for expression of proteins known to interact with SNARE proteins. Insulin resistance was determined by a euglycemic hyperinsulinemic clamp. Potential mechanisms for regulation of SNAP23 were also investigated in the skeletal muscle cell line L6. RESULTS: We showed increased SNAP23 levels in skeletal muscle from patients with type 2 diabetes compared with that from lean control subjects. Moreover, SNAP23 was redistributed from the plasma membrane to the microsomal/cytosolic compartment in the patients with the type 2 diabetes. Expression of the SNARE-interacting protein Munc18c was higher in skeletal muscle from patients with type 2 diabetes. Studies in L6 cells showed that Munc18c promoted the expression of SNAP23. CONCLUSIONS: We have translated our previous in vitro results into humans by showing that there is a change in the distribution of SNAP23 to the interior of the cell in skeletal muscle from patients with type 2 diabetes. We also showed that Munc18c is a potential regulator of SNAP23.
  •  
2.
  •  
3.
  • Hedberg, Maria E., et al. (författare)
  • Prevotella jejuni sp. nov., isolated from the small intestine of a child with celiac disease.
  • 2013
  • Ingår i: International journal of systematic and evolutionary microbiology. - : Microbiology Society. - 1466-5034 .- 1466-5026. ; 63:11, s. 4218-4223
  • Tidskriftsartikel (refereegranskat)abstract
    • Five obligately anaerobic, Gram-negative, saccharolytic and proteolytic, non-spore-forming bacilli (CD3:27, CD3:28T, CD3:33, CD3:32 and CD3:34) are described. All five strains were isolated from the small intestine of a female child with celiac disease. The cells of the five strains were observed to be short rods or coccoid cells with longer filamentous forms seen sporadically. The organisms produced acetic acid and succinic acid as major metabolic end products. Phylogenetic analysis, based on comparative 16S rRNA gene sequence analysis revealed close relationships between CD3:27, CD3:28T and CD3:33 on one hand, between CD3:32 and P. histicola CCUG 55407T and between CD3:34 and P. melaninogenica CCUG 4944BT on the other. The strains CD3:27, CD3:28T and CD3:33 were clearly different from any other species within the genus Prevotella and most closely related to but distinct from P. melaninogenica. Based on 16S rRNA gene, RNA polymerase β-subunit gene and 60-kDa chaperonin protein subunit gene sequencing, phenotypic, chemical and biochemical properties strains CD3:27, CD3:28T and CD3:33 have been determined to represent a novel species within the genus Prevotella, named Prevotella jejuni sp. nov. Strain CD3:28T (CCUG 60371T = DSM 26989T) is the type strain of the proposed new species. All five strains were able to form homologous aggregates, in which tube-like structures were connecting individual bacteria cells. The five strains were able to bind to human intestinal carcinoma cell lines at 37 °C.
  •  
4.
  • Högberg, Jonas, 1976, et al. (författare)
  • Bremsstrahlung imaging of 90Y microspheres shows poor resemblance with distributions of 99mTc-MAA in liver
  • 2010
  • Ingår i: Journal of the European Society of Therapeutic Radiology and Oncology. - 0167-8140. ; 94:1, s. 25-26
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • PURPOSE To study the resemblance between the distributions of pre- therapeutic 99mTc-MAA and therapeutic 90Y-microspheres, used for ra- dioembolization of liver tumours, making use of gamma- and bremsstrahlung imaging. Furthermore, to establish the accuracy of this method by compar- isons of spatial resolution and radioactivity, performed on line source in water phantom and on resected tumour and normal liver from patients previously treated with 90Y-microspheres. MATERIALS 3 patients diagnosed with liver tumours and planned for surgery; 1 with hepatocellular carcinoma and 2 with cholangiocarcinoma, were treated with SIRTEX R © 90Y-microspheres after standard diagnostic SPECT/CT imag- ing with 99mTc-MAA. The images acquired with gamma camera were com- pared regarding distributions of radioactivity; gamma radiation from the 99mTc-MAA distributions and bremsstrahlung from the distributions of 90Y- microspheres (the latter with a wide bremsstrahlung energy window). Resec- tions of tumour- and some normal liver tissues were performed on all three patients; the resected tissues were sliced, smaller samples were punched out and the radioactivity was measured with a NaI-detector. Furthermore, autoradiography was performed on some slices. A line source with the in- ner diameter 1 mm was positioned in a cylindrical water phantom with the diameter 20 cm; first the line source was filled with 99mTc, then emptied and filled with 90Y. SPECT/CT imaging was performed on both line source se- tups. The spatial resolutions for both radionuclides were then compared. The results from the imaging comparisons performed on the patients were then evaluated with the complementary radiological methods described above. RESULTS The comparison of images from 99mTc-MAA and 90Y showed a considerable deviance in activity distribution for two of the patients. One ex- ample is shown in the figure, the upper image showing 99mTc-MAA and the lower showing 90Y-microspheres. The moderate difference in spatial resolu- tions for 99mTc and 90Y, (15 vs 18 mm FWHM) confirmed the accuracy of these findings. The other radiological methods did also confirm the macro- scopic activity distribution as shown with bremsstrahlung imaging. CONCLUSIONS Bremsstrahlung imaging is a satisfying and reliable method in showing the actual macroscopic distribution of therapeutic 90Y-microspheres used for radioembolization of liver tumours. The results further demonstrate the need for a better diagnostic method than the one currently used, with 99mTc-MAA, thereby providing a better pre-dosimetry; hopefully with a better selection of patients, regarding tumour regression and a lower risk of liver failure.
  •  
5.
  • Högberg, Jonas, 1976, et al. (författare)
  • Heterogeneity of microsphere distribution in resected liver and tumour tissue following selective intrahepatic radiotherapy
  • 2014
  • Ingår i: EJNMMI Research. - : Springer Science and Business Media LLC. - 2191-219X. ; 4:48
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Selective arterial radioembolisation of liver tumours has increased, because of encouraging efficacy reports; however, therapeutic parameters used in external beam therapy are not applicable for understanding and predicting potential toxicity and efficacy, necessitating further studies of the physical and biological characteristics of radioembolisation. The aim was to characterise heterogeneity in the distribution of microspheres on a therapeutically relevant geometric scale considering the range of yttrium-90 (90Y) β-particles. METHODS Two patients with intrahepatic cholangiocarcinoma, marginally resectable, were treated by selective arterial embolisation with 90Y resin microspheres (SIRTEX®), followed 9 days post-infusion by resection, including macroscopic tumour tissue and surrounding normal liver parenchyma. Formalin-fixed, sectioned resected tissues were exposed to autoradiographic films, or tissue biopsies of various dimensions were punched out for activity measurements and microscopy. RESULTS Autoradiography and activity measurements revealed a higher activity in tumour tissue compared to normal liver parenchyma. Heterogeneity in activity distribution was evident in both normal liver and tumour tissue. Activity measurements were analysed in relation to the sample mass (5 to 422 mg), and heterogeneities were detected by statistical means; the larger the tissue biopsies, the smaller was the coefficient of variation. The skewness of the activity distributions increased with decreasing biopsy mass. CONCLUSIONS The tissue activity distributions in normal tissue were heterogeneous on a relevant geometric scale considering the range of the ionising electrons. Given the similar and repetitive structure of the liver parenchyma, this finding could partly explain the tolerance of a relatively high mean absorbed dose to the liver parenchyma from β-particles. Keywords: Radioembolisation; Y-90; SIR; Surgery; Activity heterogeneity
  •  
6.
  • Högberg, Jonas, 1976, et al. (författare)
  • On the dose heterogeneity in normal liver tissue due to treatment of liver tumors with yttrium-90 microspheres
  • 2012
  • Ingår i: 25th Annual Congress on European Association of Nuclear Medicine, Milano, Italy, October 27-31, 2012. European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 39:suppl 2
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Aim: When treating patients with primary or metastatic liver cancer, applying external radiotherapy, an absorbed dose of 30 - 35 Gy to the whole normal liver tissue volume is associated with a 5 % risk of radiation-induced hepatitis. If less than half of the normal liver volume is being exposed, the threshold for a 5 % risk of hepatitis is increased to above 60 Gy for both primary and metastatic liver cancer. Experience with patients treated with SIR-Spheres® (Sirtex Medical Ltd.), resin microspheres aggregated with yttrium-90, has shown that most patients tolerate an average absorbed dose to normal liver tissue higher than 60 Gy. The high tolerance for this treatment procedure can probably be explained by the resulting heterogenic distribution of radioactivity. It is of interest to study the degree of heterogeneity in the distribution of radioactivity in normal liver tissue, in order to explain or even predict the tolerance to radiation. The aim of this study was to describe the degree of heterogeneity by comparing the relative standard deviations of the radioactivity concentration for different sample mass categories. Materials and Methods: Two patients with cholangiocarcinoma were planned for a combined treatment with yttrium-90-aggregated SIR-Spheres followed by surgery 9 days after radiotherapy. According to standard protocol for treatments with SIR-Spheres, the therapies were preceded by Tc-99m-labled Macro aggregated albumin (Tc-99m-MAA) distribution studies for pre-therapeutic dosimetry and lung shunting evaluations. After surgery the resected tissue, containing both tumour and normal tissue, was studied regarding the distribution of radioactivity. Several small circular samples of normal liver tissue were punched out from 2 mm thick slices of resected tissue, deliberately varying the sizes, and thus the masses of the tissue samples (from 6 to 102 mg). The samples were weighed and categorized in two (first patient) and three (second patient) groups, depending on sample mass. After this the radioactivity was measured with a NaI(Tl) detector. The relative standard deviations (SD/Median) for the radioactivity concentration for each sample mass group were determined and compared. Results: The relative standard deviation for the radioactivity concentration was decreasing rapidly with increasing sample mass. Conclusion: The results indicate a considerable degree of heterogeneity in the distribution of microspheres. One probable explanation for this heterogeneity is clustering of microspheres in the blood vessels.
  •  
7.
  • Högberg, Jonas, 1976, et al. (författare)
  • Radiation exposure during liver surgery after treatment with (90)Y microspheres, evaluated with computer simulations and dosimeter measurements.
  • 2012
  • Ingår i: Journal of radiological protection : official journal of the Society for Radiological Protection. - : IOP Publishing. - 1361-6498. ; 32:4, s. 439-46
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose. Two patients with liver tumours were planned for a combined treatment, including surgery with preceding injections of β(-) radiation emitting (90)Y microspheres (SIRTEX(®)). The aim of this paper is to present a method of pre-surgical computer simulations of the absorbed dose rate on the surface of tumour tissue, combined with measurements of the actual absorbed dose rate on resected tissue, in order to estimate the absorbed dose to a surgeon's fingers during such surgery procedures. Methods and Materials. The dose rates from β(-) radiation on the surface of tumour tissue were simulated with the software VARSKIN(®)Mod2. The activity concentrations in tumours were estimated, based on SPECT/CT distribution studies of (99m)Tc-MAA and confirmed by SPECT/CT bremsstrahlung studies of (90)Y microspheres. The activity distributions were considered as homogeneous within the tumour regions. The absorbed dose rates at different tumour tissue spots were calculated based on measurements with thermo-luminescent dosimeters (TLD) fastened on resected tissue. Results. The simulations showed a good agreement with the averaged absorbed dose rates based on TLD measurements performed on resected tissue, differing by 13% and 4% respectively. The absorbed dose rates at the measured maximum hotspots were twice as high as the average dose rates for both patients. Conclusion. The data is not sufficient in order to draw any general conclusions about dose rates on tumour tissue during similar surgeries, neither about the influence of dose rate heterogeneities nor about average dose rates. However, the agreement between simulations and measurements on these limited data indicate that this approach is a promising method for estimations of the radiation exposure to the surgeons' fingers during this kind of surgery procedure. More data from similar surgeries are necessary in order to validate the method.
  •  
8.
  • Kristiansson, Marianne, et al. (författare)
  • Sekretess hinder för hantering av högriskindivider.
  • 2014
  • Ingår i: Svenska Dagbladet. - 1101-2412. ; :21 nov 2014
  • Tidskriftsartikel (populärvet., debatt m.m.)abstract
    • För att olika myndigheter ska kunna samverka när det gäller personer med psykisk sjukdom som riskerar att begå brott, krävs att nuvarande sekretessbestämmelser förändras.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8
Typ av publikation
tidskriftsartikel (6)
konferensbidrag (2)
Typ av innehåll
refereegranskat (5)
övrigt vetenskapligt/konstnärligt (2)
populärvet., debatt m.m. (1)
Författare/redaktör
Hultborn, Ragnar, 19 ... (4)
Svensson, Johanna (4)
Bernhardt, Peter, 19 ... (4)
Rizell, Magnus, 1963 (4)
Henrikson, Olof (4)
Gjertsson, Peter, 19 ... (4)
visa fler...
Högberg, Jonas, 1976 (4)
Svensson, Olof (2)
Josefson, Mats (1)
Abrahamsson, Katarin ... (1)
Jansson, Per-Anders, ... (1)
Mölne, Johan, 1958 (1)
Moore, Edward R.B. 1 ... (1)
Engelbrektsson, Joha ... (1)
Olofsson, Sven-Olof, ... (1)
Borén, Jan, 1963 (1)
Andersson, Linda, 19 ... (1)
Andiné, Peter (1)
Svensson, M.K, 1965 (1)
Wai, Sun Nyunt (1)
Ling, Charlotte (1)
Hernell, Olle (1)
Larsson, Erik, 1975 (1)
Israelsson, Anne (1)
Kristiansson, Marian ... (1)
Sandström, Olof (1)
Boström, Pontus, 198 ... (1)
Rutberg, Mikael, 195 ... (1)
Håversen, Liliana, 1 ... (1)
Sturup, Joakim (1)
Brånemark, Rickard, ... (1)
Wickström, Ylva (1)
Højlund, Kurt (1)
Vind, Birgitte (1)
Beck-Nielsen, Hennin ... (1)
Breitholz, Johan (1)
Nicholas, Mark (1)
Wikström, H (1)
Hammarström, Marie-L ... (1)
Svensson-Stadler, Li ... (1)
Hedberg, Maria E (1)
Pietz, Grzegorz (1)
Hammarstrom, Sten (1)
Sörman, K (1)
visa färre...
Lärosäte
Umeå universitet (1)
Lunds universitet (1)
Karolinska Institutet (1)
Språk
Engelska (7)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (7)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy