SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Taccone FS) ;pers:(Belohlavek J)"

Sökning: WFRF:(Taccone FS) > Belohlavek J

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Cvetkovic, M, et al. (författare)
  • International survey of neuromonitoring and neurodevelopmental outcome in children and adults supported on extracorporeal membrane oxygenation in Europe
  • 2023
  • Ingår i: Perfusion. - : SAGE Publications. - 1477-111X .- 0267-6591. ; 38:2, s. 245-260
  • Tidskriftsartikel (refereegranskat)abstract
    • Adverse neurological events during extracorporeal membrane oxygenation (ECMO) are common and may be associated with devastating consequences. Close monitoring, early identification and prompt intervention can mitigate early and late neurological morbidity. Neuromonitoring and neurocognitive/neurodevelopmental follow-up are critically important to optimize outcomes in both adults and children. Objective: To assess current practice of neuromonitoring during ECMO and neurocognitive/neurodevelopmental follow-up after ECMO across Europe and to inform the development of neuromonitoring and follow-up guidelines. Methods: The EuroELSO Neurological Monitoring and Outcome Working Group conducted an electronic, web-based, multi-institutional, multinational survey in Europe. Results: Of the 211 European ECMO centres (including non-ELSO centres) identified and approached in 23 countries, 133 (63%) responded. Of these, 43% reported routine neuromonitoring during ECMO for all patients, 35% indicated selective use, and 22% practiced bedside clinical examination alone. The reported neuromonitoring modalities were NIRS ( n = 88, 66.2%), electroencephalography ( n = 52, 39.1%), transcranial Doppler ( n = 38, 28.5%) and brain injury biomarkers ( n = 33, 24.8%). Paediatric centres (67%) reported using cranial ultrasound, though the frequency of monitoring varied widely. Before hospital discharge following ECMO, 50 (37.6%) reported routine neurological assessment and 22 (16.5%) routinely performed neuroimaging with more paediatric centres offering neurological assessment (65%) as compared to adult centres (20%). Only 15 (11.2%) had a structured longitudinal follow-up pathway (defined followup at regular intervals), while 99 (74.4%) had no follow-up programme. The majority ( n = 96, 72.2%) agreed that there should be a longitudinal structured follow-up for ECMO survivors. Conclusions: This survey demonstrated significant variability in the use of different neuromonitoring modalities during and after ECMO. The perceived importance of neuromonitoring and follow-up was noted to be very high with agreement for a longitudinal structured follow-up programme, particularly in paediatric patients. Scientific society endorsed guidelines and minimum standards should be developed to inform local protocols.
  •  
2.
  • Di Nardo, M, et al. (författare)
  • A narrative review of the technical standards for extracorporeal life support devices (pumps and oxygenators) in Europe
  • 2018
  • Ingår i: Perfusion. - : SAGE Publications. - 1477-111X .- 0267-6591. ; 33:7, s. 553-561
  • Tidskriftsartikel (refereegranskat)abstract
    • This review summarizes the European rules to control the market when introducing new products. In particular, it shows all the steps to achieve the European Conformity (CE Mark), a certification that all new medical products must achieve before being used in Europe. Extracorporeal membrane oxygenation (ECMO) devices are exposed to the same procedures. Hereby, we present some regulatory issues regarding pumps and oxygenators, providing technical details as released by the manufacturers on their websites and information charts.
  •  
3.
  •  
4.
  • Malfertheiner, MV, et al. (författare)
  • Ex vivo models for research in extracorporeal membrane oxygenation: a systematic review of the literature
  • 2020
  • Ingår i: Perfusion. - : SAGE Publications. - 1477-111X .- 0267-6591. ; 35:1_suppl, s. 38-49
  • Tidskriftsartikel (refereegranskat)abstract
    • With ongoing progress of components of extracorporeal membrane oxygenation including improvements of oxygenators, pumps, and coating materials, extracorporeal membrane oxygenation became increasingly accepted in the clinical practice. A suitable testing in an adequate setup is essential for the development of new technical aspects. Relevant tests can be conducted in ex vivo models specifically designed to test certain aspects. Different setups have been used in the past for specific research questions. We conducted a systematic literature review of ex vivo models of extracorporeal membrane oxygenation components. MEDLINE and Embase were searched between January 1996 and October 2017. The inclusion criteria were ex vivo models including features of extracorporeal membrane oxygenation technology. The exclusion criteria were clinical studies, abstracts, studies in which the model of extracorporeal membrane oxygenation has been reported previously, and studies not reporting on extracorporeal membrane oxygenation components. A total of 50 studies reporting on different ex vivo extracorporeal membrane oxygenation models have been identified from the literature search. Models have been grouped according to the specific research question they were designed to test for. The groups are focused on oxygenator performance, pump performance, hemostasis, and pharmacokinetics. Pre-clinical testing including use of ex vivo models is an important step in the development and improvement of extracorporeal membrane oxygenation components and materials. Furthermore, ex vivo models offer valuable insights for clinicians to better understand the consequences of choice of components, setup, and management of an extracorporeal membrane oxygenation circuit in any given condition. There is a need to standardize the reporting of pre-clinical studies in this area and to develop best practice in their design.
  •  
5.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy