SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Thungström Göran) "

Sökning: WFRF:(Thungström Göran)

  • Resultat 1-10 av 130
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Reifarth, R., et al. (författare)
  • Nuclear astrophysics with radioactive ions at FAIR
  • 2016
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 665:1
  • Konferensbidrag (refereegranskat)abstract
    • The nucleosynthesis of elements beyond iron is dominated by neutron captures in the s and r processes. However, 32 stable, proton-rich isotopes cannot be formed during those processes, because they are shielded from the s-process flow and r-process beta-decay chains. These nuclei are attributed to the p and rp process. For all those processes, current research in nuclear astrophysics addresses the need for more precise reaction data involving radioactive isotopes. Depending on the particular reaction, direct or inverse kinematics, forward or time-reversed direction are investigated to determine or at least to constrain the desired reaction cross sections. The Facility for Antiproton and Ion Research (FAIR) will offer unique, unprecedented opportunities to investigate many of the important reactions. The high yield of radioactive isotopes, even far away from the valley of stability, allows the investigation of isotopes involved in processes as exotic as the r or rp processes.
  •  
2.
  • Akbari-Saatlu, Mehdi, et al. (författare)
  • H2S gas sensing based on SnO2thin films deposited by ultrasonic spray pyrolysis on Al2O3substrate
  • 2021
  • Ingår i: 2021 IEEE Sensors Applications Symposium (SAS). - 9781728194318
  • Konferensbidrag (refereegranskat)abstract
    • H2S gas is harmful for human health and environment, therefore novel gas sensors for real time and fast detection with high precision have been sought. Metal oxides are already known as promising candidate for this purpose. This article presents the performance of a gas sensor consists of a microheater and active layer formed on single alumina substrate for operating at high temperature applications. Ultrasonic spray pyrolysis deposition method was used to make both thick layer of SnO2 for microheater and thin and porous crystalline layer of SnO2 as sensing layer. The prepared sensor showed suitable dynamic response towards 10 to 50 ppm of H2S gas both in humid and dry conditions at 450 °C. In these experiments, the cross sensitivity of the sensor was also checked for other interfering gases e.g. CH4 and NO2.
  •  
3.
  • Akbari-Saatlu, Mehdi, et al. (författare)
  • Nanometer-Thick ZnO/SnO2Heterostructures Grown on Alumina for H2S Sensing
  • 2022
  • Ingår i: ACS Applied Nano Materials. - : American Chemical Society (ACS). - 2574-0970. ; 5:5, s. 6954-6963
  • Tidskriftsartikel (refereegranskat)abstract
    • Designing heterostructure materials at the nanoscale is a well-known method to enhance gas sensing performance. In this study, a mixed solution of zinc chloride and tin (II) chloride dihydrate, dissolved in ethanol solvent, was used as the initial precursor for depositing the sensing layer on alumina substrates using the ultrasonic spray pyrolysis (USP) method. Several ZnO/SnO2 heterostructures were grown by applying different ratios in the initial precursors. These heterostructures were used as active materials for the sensing of H2S gas molecules. The results revealed that an increase in the zinc chloride in the USP precursor alters the H2S sensitivity of the sensor. The optimal working temperature was found to be 450 °C. The sensor, containing 5:1 (ZnCl2: SnCl2·2H2O) ratio in the USP precursor, demonstrates a higher response than the pure SnO2 (∼95 times) sample and other heterostructures. Later, the selectivity of the ZnO/SnO2 heterostructures toward 5 ppm NO2, 200 ppm methanol, and 100 ppm of CH4, acetone, and ethanol was also examined. The gas sensing mechanism of the ZnO/SnO2 was analyzed and the remarkably enhanced gas-sensing performance was mainly attributed to the heterostructure formation between ZnO and SnO2. The synthesized materials were also analyzed by X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray, transmission electron microscopy, and X-ray photoelectron spectra to investigate the material distribution, grain size, and material quality of ZnO/SnO2 heterostructures. 
  •  
4.
  • Akbari-Saatlu, Mehdi, et al. (författare)
  • Silicon Nanowires for Gas Sensing : A Review
  • 2020
  • Ingår i: Nanomaterials. - : MDPI AG. - 2079-4991. ; 10:11
  • Forskningsöversikt (refereegranskat)abstract
    • The unique electronic properties of semiconductor nanowires, in particular silicon nanowires (SiNWs), are attractive for the label-free, real-time, and sensitive detection of various gases. Therefore, over the past two decades, extensive efforts have been made to study the gas sensing function of NWs. This review article presents the recent developments related to the applications of SiNWs for gas sensing. The content begins with the two basic synthesis approaches (top-down and bottom-up) whereby the advantages and disadvantages of each approach have been discussed. Afterwards, the basic sensing mechanism of SiNWs for both resistor and field effect transistor designs have been briefly described whereby the sensitivity and selectivity to gases after different functionalization methods have been further presented. In the final words, the challenges and future opportunities of SiNWs for gas sensing have been discussed.
  •  
5.
  • Ambatipudi, Radhika, 1982- (författare)
  • High Frequency (MHz) Planar Transformers for Next Generation Switch Mode Power Supplies
  • 2013
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Increasing the power density of power electronic converters while reducing or maintaining the same cost, offers a higher potential to meet the current trend inrelation to various power electronic applications. High power density converters can be achieved by increasing the switching frequency, due to which the bulkiest parts, such as transformer, inductors and the capacitor's size in the convertercircuit can be drastically reduced. In this regard, highly integrated planar magnetics are considered as an effective approach compared to the conventional wire wound transformers in modern switch mode power supplies (SMPS). However, as the operating frequency of the transformers increase from several hundred kHz to MHz, numerous problems arise such as skin and proximity effects due to the induced eddy currents in the windings, leakage inductance and unbalanced magnetic flux distribution. In addition to this, the core losses whichare functional dependent on frequency gets elevated as the operating frequency increases. Therefore, this thesis provides an insight towards the problems related to the high frequency magnetics and proposes a solution with regards to different aspects in relation to designing high power density, energy efficient transformers.The first part of the thesis concentrates on the investigation of high power density and highly energy efficient coreless printed circuit board (PCB) step-down transformers useful for stringent height DC-DC converter applications, where the core losses are being completely eliminated. These transformers also maintain the advantages offered by existing core based transformers such as, high coupling coefficient, sufficient input impedance, high energy efficiency and wide frequencyband width with the assistance of a resonant technique. In this regard, several coreless PCB step down transformers of different turn’s ratio for power transfer applications have been designed and evaluated. The designed multilayered coreless PCB transformers for telecom and PoE applications of 8,15 and 30W show that the volume reduction of approximately 40 - 90% is possible when compared to its existing core based counterparts while maintaining the energy efficiency of the transformers in the range of 90 - 97%. The estimation of EMI emissions from the designed transformers for the given power transfer application proves that the amount of radiated EMI from a multilayered transformer is lessthan that of the two layered transformer because of the decreased radius for thesame amount of inductance.The design guidelines for the multilayered coreless PCB step-down transformer for the given power transfer application has been proposed. The designed transformer of 10mm radius has been characterized up to the power level of 50Wand possesses a record power density of 107W/cm3 with a peak energy efficiency of 96%. In addition to this, the design guidelines of the signal transformer fordriving the high side MOSFET in double ended converter topologies have been proposed. The measured power consumption of the high side gate drive circuitvitogether with the designed signal transformer is 0.37W. Both these signal andpower transformers have been successfully implemented in a resonant converter topology in the switching frequency range of 2.4 – 2.75MHz for the maximum load power of 34.5W resulting in the peak energy efficiency of converter as 86.5%.This thesis also investigates the indirect effect of the dielectric laminate on the magnetic field intensity and current density distribution in the planar power transformers with the assistance of finite element analysis (FEA). The significanceof the high frequency dielectric laminate compared to FR-4 laminate in terms of energy efficiency of planar power transformers in MHz frequency region is also explored.The investigations were also conducted on different winding strategies such as conventional solid winding and the parallel winding strategies, which play an important role in the design and development of a high frequency transformer and suggested a better choice in the case of transformers operating in the MHz frequency region.In the second part of the thesis, a novel planar power transformer with hybrid core structure has been designed and evaluated in the MHz frequency region. The design guidelines of the energy efficient high frequency planar power transformerfor the given power transfer application have been proposed. The designed corebased planar transformer has been characterized up to the power level of 50W and possess a power density of 47W/cm3 with maximum energy efficiency of 97%. This transformer has been evaluated successfully in the resonant converter topology within the switching frequency range of 3 – 4.5MHz. The peak energy efficiency ofthe converter is reported to be 92% and the converter has been tested for the maximum power level of 45W, which is suitable for consumer applications such as laptop adapters. In addition to this, a record power density transformer has been designed with a custom made pot core and has been characterized in thefrequency range of 1 - 10MHz. The power density of this custom core transformer operating at 6.78MHz frequency is 67W/cm3 and with the peak energy efficiency of 98%.In conclusion, the research in this dissertation proposed a solution for obtaining high power density converters by designing the highly integrated, high frequency(1 - 10MHz) coreless and core based planar magnetics with energy efficiencies inthe range of 92 - 97%. This solution together with the latest semiconductor GaN/SiC switching devices provides an excellent choice to meet the requirements of the next generation ultra flat low profile switch mode power supplies (SMPS).
  •  
6.
  • An, Siwen, et al. (författare)
  • Comparison of Elemental Analysis Techniques for Fly Ash from Municipal Solid Waste Incineration using X-rays and Electron Beams
  • 2019
  • Ingår i: IOP Conference Series. - : Institute of Physics (IOP).
  • Konferensbidrag (refereegranskat)abstract
    • With the rapid expansion of the waste incineration business both in Europe and globally, there is a growing need for the elemental analysis for fly ash from municipal solid waste incineration. In this work, samples of washed and unwashed ash from municipal solid waste incineration in Sundsvall are evaluated. Qualitative analysis and semi-quantitative analysis are used to compare two elemental analysis methods, scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and X-ray fluorescence (XRF) measurement. Both methods are used to retrieve the difference in elemental composition between washed and unwashed fly ash. SEM-EDS accurately detects light elements from well-prepared samples in a vacuum environment, while, for online measurements, XRF is a potential method that analyses hazardous metal content in the fly ash. 
  •  
7.
  • An, Siwen, et al. (författare)
  • Effects of Water Absorption on Mercury Contamination in Fiberbank Sediments using X-ray Fluorescence Spectrometer
  • 2021
  • Ingår i: IOP Conference Series: Earth and Environmental Science. - : Institute of Physics (IOP). - 1755-1307 .- 1755-1315.
  • Konferensbidrag (refereegranskat)abstract
    • A large amount of contaminated cellulose and wood fibers were emitted directly onto the seabed by the pulp and paper industry before the year of 1970. This fiber-rich sediment contains concentrations of hazardous substances that cause environmental problems. Mercury (Hg) in the fiber sediment is a worldwide threat because it can bioaccumulate in the aquatic ecosystem and eventually affect human health. X-ray fluorescence (XRF) analysis is anelemental analysis method for earth materials, which is rapid and requires minimal sample preparation. However, for in-situ XRF analyses, constraints in the measurement conditions will strongly affect the measurement sensitivity and accuracy, such as the scattered background and the water content surrounding the sample. In this work, we showed that applying an X-ray beam filter foil, optimized by using the material absorption edge, can improve the sensitivity of the XRF spectrometer system for Hg determination. Furthermore, the influence of water content in XRF measurement for Hg contamination analysis was investigated. The attenuation coefficient in water was determined by simulation of water layer with varying thickness using a Monte Carlo simulation code. The measured intensity for Hg was decreased exponentially asthe water thickness increase, as expected. We propose a method to correct the attenuation in water with XRF analysis and we expect that these findings can contribute to an accurate in-situ Hg detection experiment.
  •  
8.
  • An, Siwen, et al. (författare)
  • Full-field X-ray fluorescence imaging with a straight polycapillary X-ray collimator
  • 2020
  • Ingår i: Journal of Instrumentation. - 1748-0221 .- 1748-0221. ; 15:12
  • Tidskriftsartikel (refereegranskat)abstract
    • Due to the availability of X-ray imaging detectors, full-field X-ray fluorescence (FF-XRF) imaging technique has become achievable, which provides an alternative to scanning X-ray fluorescence imaging with a micro-focus X-ray beamline. In this paper, we present a setup based on straight capillary optics and an energy-dispersive hybrid pixel detector, which can perform simultaneous mapping of several chemical elements. The photon transmission efficiency and spatial resolution are compared between two X-ray collimation setups: one using pinhole optics and one using straight polycapillary optics. There is a tradeoff between the spatial resolution and transmission efficiency when considering X-ray optics. When optimizing the spatial resolution, using straight capillary optics achieved a higher intensity gain when comparing with the pinhole setup. Characterization of the polycapillary imaging setup is performed through analyzing various samples in order to investigate the spatial frequency response and the energy sensitivity. This developed setup is capable of FF-XRF imaging in characteristic energies below 20 keV, while for higher energies the spatial resolution is affected by photon transmission through the collimator. This work shows the potential of the FF-XRF instrument in the monitoring of toxic metal distributions in environmental mapping measurements.
  •  
9.
  • An, Siwen, et al. (författare)
  • Geometrical influence on Hg determination in wet sediment using K-shell fluorescence analysis
  • 2023
  • Ingår i: X-Ray Spectrometry. - : John Wiley and Sons Ltd. - 0049-8246 .- 1097-4539. ; 52:4, s. 82-196
  • Tidskriftsartikel (refereegranskat)abstract
    • To quickly identify maritime sites polluted by heavy metal contaminants, reductions in the size of instrumentation have made it possible to bring an X-ray fluorescence (XRF) analyzer into the field and in direct contact with various samples. The choice of source-sample-detector geometry plays an important role in minimizing the Compton scattering noise and achieving a better signal-to-noise ratio (SNR) in XRF measurement conditions, especially for analysis of wet sediments. This paper presents the influence of geometrical factors on a prototype, designed for in situ XRF analysis of mercury (Hg) in wet sediments using a 57Co excitation source and an X-ray spectrometer. The unique XRF penetrometer prototype has been constructed and tested for maritime wet sediment. The influence on detection efficiency and SNR of various geometrical arrangements have been investigated using the combination of Monte Carlo simulations and laboratory experiments. Instrument calibration was performed for Hg analysis by means of prepared wet sediments with the XRF prototype. The presented results show that it is possible to detect Hg by K-shell emission, thus enabling XRF analysis for underwater sediments. Consequently, the XRF prototype has the potential to be applied as an environmental screening tool for analysis of polluted sediments with relatively high concentrations (e.g., >2880 ppm for Hg), which would benefit in situ monitoring of maritime pollution caused by heavy metals. © 2022 The Authors
  •  
10.
  • An, Siwen, et al. (författare)
  • Signal-to-Noise Ratio Optimization in X-ray Fluorescence Spectrometry for Chromium Contamination Analysis
  • 2021
  • Ingår i: Talanta. - : Elsevier BV. - 0039-9140 .- 1873-3573. ; 230
  • Tidskriftsartikel (refereegranskat)abstract
    • In most cases, direct X-ray fluorescence (XRF) analysis of solutions entails technical difficulties due to a high X-ray scattering background resulting in a spectrum with a poor signal-to-noise ratio (SNR). Key factors that determine the sensitivity of the method are the energy resolution of the detector and the amount of scattered radiation in the energy range of interest. Limiting the width of the primary spectrum by the use of secondary targets, or filters, can greatly improve the sensitivity for specific portions of the spectrum. This paper demonstrates a potential method for SNR optimization in direct XRF analysis of chromium (Cr) contamination. The suggested method requires minimal sample preparation and achieves higher sensitivity compared to existing direct XRF analysis. Two states of samples, fly ash and leachate from municipal solid waste incineration, were investigated. The effects of filter material, its absorption edge and filter thickness were analyzed using the combination of Monte Carlo N-Particle (MCNP) code and energy-dispersive XRF spectrometry. The applied filter removes primary photons with energies interfering with fluorescence photons from the element of interest, thus results in lower background scattering in the spectrum. The SNR of Cr peak increases with filter thickness and reaches a saturation value when further increased thickness only increases the measurement time. Measurements and simulations show that a Cu filter with a thickness between 100 μm and 140 μm is optimal for detecting Cr by taking into account both the SNR and the exposure time. With direct XRF analysis for solutions, the limit of quantitation (LOQ) of the achieved system was 0.32 mg/L for Cr, which is well below the allowed standard limitation for landfills in Sweden. This work shows that XRF can gain enough sensitivity for direct monitoring to certify that the Cr content in leachate is below environmental limits.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 130
Typ av publikation
tidskriftsartikel (70)
konferensbidrag (42)
doktorsavhandling (9)
licentiatavhandling (7)
annan publikation (1)
forskningsöversikt (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (103)
övrigt vetenskapligt/konstnärligt (27)
Författare/redaktör
Thungström, Göran (85)
Thungström, Göran, 1 ... (40)
Nilsson, Hans-Erik (37)
Fröjdh, Christer (33)
Mattsson, Claes, 197 ... (19)
Petersson, Sture (17)
visa fler...
Andersson, Henrik (11)
Norlin, Börje, 1967- (11)
Mattsson, Claes (11)
Bertilsson, Kent (9)
Ashraf, Shakeel, 198 ... (9)
Pospisil, S. (7)
An, Siwen (7)
Hummelgård, Christin ... (7)
Reza, Salim, 1985- (6)
Manuilskiy, Anatoliy (5)
Jakubek, J. (4)
Fröjdh, Christer, 19 ... (4)
Lundgren, Anders (4)
Kohout, Z. (3)
Radamson, Henry H. (3)
Slavicek, Tomas (3)
Andersson, Henrik, 1 ... (3)
Akbari-Saatlu, Mehdi (3)
Procek, Marcin, 1987 ... (3)
Krapohl, David, PhD, ... (3)
Hummelgård, Magnus, ... (3)
Lundgren, A. (3)
Brenner, Richard (2)
Vykydal, Z. (2)
O'Shea, V. (2)
Linhart, V. (2)
Dubaric, Ervin (2)
O'Nils, Mattias (2)
Pallon, Jan (2)
Elfman, Mikael (2)
Kristiansson, Per (2)
Nilsson, Charlotta (2)
Engstrand, Per, Prof ... (2)
Nilsson, Christer (2)
Sjöström, Mårten, 19 ... (2)
Rödjegård, Henrik (2)
Zhang, Renyun (2)
Sund, Johan (2)
Engholm, Magnus (2)
Olin, Håkan, 1957- (2)
Nnonyelu, Chibuzo Jo ... (2)
Parker, S (2)
Arteaga, Natalia (2)
Wegdén, Marie (2)
visa färre...
Lärosäte
Mittuniversitetet (130)
Kungliga Tekniska Högskolan (8)
Högskolan i Gävle (6)
Uppsala universitet (5)
Lunds universitet (4)
Chalmers tekniska högskola (2)
visa fler...
RISE (1)
visa färre...
Språk
Engelska (130)
Forskningsämne (UKÄ/SCB)
Teknik (110)
Naturvetenskap (27)
Medicin och hälsovetenskap (2)
Lantbruksvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy