SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Trägårdh Elin) ;pers:(Almquist Helen)"

Search: WFRF:(Trägårdh Elin) > Almquist Helen

  • Result 1-5 of 5
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Abrahamsson, Johan, et al. (author)
  • Complete metabolic response with [18F]fluorodeoxyglucose-positron emission tomography/computed tomography predicts survival following induction chemotherapy and radical cystectomy in clinically lymph node positive bladder cancer
  • 2022
  • In: BJU International. - : Wiley. - 1464-4096 .- 1464-410X. ; 129:2, s. 174-181
  • Journal article (peer-reviewed)abstract
    • Objective: To determine whether repeated [18F]fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET-CT) scans can predict increased cancer-specific survival (CSS) after induction chemotherapy followed by radical cystectomy (RC). Patients and Methods: Between 2007 and 2018, 86 patients with clinically lymph node (LN)-positive bladder cancer (T1–T4, N1–N3, M0–M1a) were included and underwent a repeated FDG-PET-CT during cisplatin-based induction chemotherapy. The 71 patients that had a response to chemotherapy underwent RC. Response to chemotherapy was evaluated in LNs through repeated FDG-PET-CT and stratified as partial response or complete response using three different methods: maximum standardised uptake value (SUVmax), adapted Deauville criteria, and total lesion glycolysis (TLG). Progression-free survival (PFS) and CSS were analysed for all three methods by Cox regression analysis. Results: After a median follow-up of 40 months, 15 of the 71 patients who underwent RC had died from bladder cancer. Using SUVmax and the adapted Deauville criteria, multivariable Cox regression analyses adjusting for age, clinical tumour stage and LN stage showed that complete response was associated with increased PFS (hazard ratio [HR] 3.42, 95% confidence interval [CI] 1.20–9.77) and CSS (HR 3.30, 95% CI 1.02–10.65). Using TLG, a complete response was also associated with increased PFS (HR 5.17, 95% CI 1.90–14.04) and CSS (HR 6.32, 95% CI 2.06–19.41). Conclusions: Complete metabolic response with FDG-PET-CT predicts survival after induction chemotherapy followed by RC in patients with LN-positive bladder cancer and comprises a novel tool in evaluating response to chemotherapy before surgery. This strategy has the potential to tailor treatment in individual patients by identifying significant response to chemotherapy, which motivates the administration of a full course of induction chemotherapy with a higher threshold for suspending treatment due to toxicity and side-effects.
  •  
2.
  • Bjöersdorff, Mimmi, et al. (author)
  • Impact of penalizing factor in a block-sequential regularized expectation maximization reconstruction algorithm for 18 F-fluorocholine PET-CT regarding image quality and interpretation
  • 2019
  • In: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 6:1
  • Journal article (peer-reviewed)abstract
    • Background: Recently, the block-sequential regularized expectation maximization (BSREM) reconstruction algorithm was commercially introduced (Q.Clear, GE Healthcare, Milwaukee, WI, USA). However, the combination of noise-penalizing factor (β), acquisition time, and administered activity for optimal image quality has not been established for 18 F-fluorocholine (FCH). The aim was to compare image quality and diagnostic performance of different reconstruction protocols for patients with prostate cancer being examined with 18 F-FCH on a silicon photomultiplier-based PET-CT. Thirteen patients were included, injected with 4 MBq/kg, and images were acquired after 1 h. Images were reconstructed with frame durations of 1.0, 1.5, and 2.0 min using β of 150, 200, 300, 400, 500, and 550. An ordered subset expectation maximization (OSEM) reconstruction with a frame duration of 2.0 min was used for comparison. Images were quantitatively analyzed regarding standardized uptake values (SUV) in metastatic lymph nodes, local background, and muscle to obtain contrast-to-noise ratios (CNR) as well as the noise level in muscle. Images were analyzed regarding image quality and number of metastatic lymph nodes by two nuclear medicine physicians. Results: The highest median CNR was found for BSREM with a β of 300 and a frame duration of 2.0 min. The OSEM reconstruction had the lowest median CNR. Both the noise level and lesion SUV max decreased with increasing β. For a frame duration of 1.5 min, the median quality score was highest for β 400-500, and for a frame duration of 2.0 min the score was highest for β 300-500. There was no statistically significant difference in the number of suspected lymph node metastases between the different image series for one of the physicians, and for the other physician the number of lymph nodes differed only for one combination of image series. Conclusions: To achieve acceptable image quality at 4 MBq/kg 18 F-FCH, we propose using a β of 400-550 with a frame duration of 1.5 min. The lower β should be used if a high CNR is desired and the higher if a low noise level is important.
  •  
3.
  •  
4.
  • Oddstig, Jenny, et al. (author)
  • Comparison of conventional and Si-photomultiplier-based PET systems for image quality and diagnostic performance
  • 2019
  • In: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 19:1
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: A new generation of positron emission tomography with computed tomography (PET-CT) was recently introduced using silicon (Si) photomultiplier (PM)-based technology. Our aim was to compare the image quality and diagnostic performance of a SiPM-based PET-CT (Discovery MI; GE Healthcare, Milwaukee, WI, USA) with a time-of-flight PET-CT scanner with a conventional PM detector (Gemini TF; Philips Healthcare, Cleveland, OH, USA), including reconstruction algorithms per vendor's recommendations. METHODS: Imaging of the National Electrical Manufacturers Association IEC body phantom and 16 patients was carried out using 1.5 min/bed for the Discovery MI PET-CT and 2 min/bed for the Gemini TF PET-CT. Images were analysed for recovery coefficients for the phantom, signal-to-noise ratio in the liver, standardized uptake values (SUV) in lesions, number of lesions and metabolic TNM classifications in patients. RESULTS: In phantom, the correct (> 90%) activity level was measured for spheres ≥17 mm for Discovery MI, whereas the Gemini TF reached a correct measured activity level for the 37-mm sphere. In patient studies, metabolic TNM classification was worse using images obtained from the Discovery MI compared those obtained from the Gemini TF in 4 of 15 patients. A trend toward more malignant, inflammatory and unclear lesions was found using images acquired with the Discovery MI compared with the Gemini TF, but this was not statistically significant. Lesion-to-blood-pool SUV ratios were significantly higher in images from the Discovery MI compared with the Gemini TF for lesions smaller than 1 cm (p < 0.001), but this was not the case for larger lesions (p = 0.053). The signal-to-noise ratio in the liver was similar between platforms (p = 0.52). Also, shorter acquisition times were possible using the Discovery MI, with preserved signal-to-noise ratio in the liver. CONCLUSIONS: Image quality was better with Discovery MI compared to conventional Gemini TF. Although no gold standard was available, the results indicate that the new PET-CT generation will provide potentially better diagnostic performance.
  •  
5.
  • Trägårdh, Elin, et al. (author)
  • Impact of acquisition time and penalizing factor in a block-sequential regularized expectation maximization reconstruction algorithm on a Si-photomultiplier-based PET-CT system for 18F-FDG
  • 2019
  • In: EJNMMI Research. - : Springer Science and Business Media LLC. - 2191-219X. ; 9:1
  • Journal article (peer-reviewed)abstract
    • Background: Block-sequential regularized expectation maximization (BSREM), commercially Q. Clear (GE Healthcare, Milwaukee, WI, USA), is a reconstruction algorithm that allows for a fully convergent iterative reconstruction leading to higher image contrast compared to conventional reconstruction algorithms, while also limiting noise. The noise penalization factor β controls the trade-off between noise level and resolution and can be adjusted by the user. The aim was to evaluate the influence of different β values for different activity time products (ATs = administered activity × acquisition time) in whole-body 18F-fluorodeoxyglucose (FDG) positron emission tomography with computed tomography (PET-CT) regarding quantitative data, interpretation, and quality assessment of the images. Twenty-five patients with known or suspected malignancies, referred for clinical 18F-FDG PET-CT examinations acquired on a silicon photomultiplier PET-CT scanner, were included. The data were reconstructed using BSREM with β values of 100–700 and ATs of 4–16 MBq/kg × min/bed (acquisition times of 1, 1.5, 2, 3, and 4 min/bed). Noise level, lesion SUVmax, and lesion SUVpeak were calculated. Image quality and lesion detectability were assessed by four nuclear medicine physicians for acquisition times of 1.0 and 1.5 min/bed position. Results: The noise level decreased with increasing β values and ATs. Lesion SUVmax varied considerably between different β values and ATs, whereas SUVpeak was more stable. For an AT of 6 (in our case 1.5 min/bed), the best image quality was obtained with a β of 600 and the best lesion detectability with a β of 500. AT of 4 generated poor-quality images and false positive uptakes due to noise. Conclusions: For oncologic whole-body 18F-FDG examinations on a SiPM-based PET-CT, we propose using an AT of 6 (i.e., 4 MBq/kg and 1.5 min/bed) reconstructed with BSREM using a β value of 500–600 in order to ensure image quality and lesion detection rate as well as a high patient throughput. We do not recommend using AT < 6 since the risk of false positive uptakes due to noise increases.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-5 of 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view