SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tufvesson Fredrik) ;lar1:(bth)"

Sökning: WFRF:(Tufvesson Fredrik) > Blekinge Tekniska Högskola

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Khan, Muhammad Gufran, et al. (författare)
  • Measurements and Analysis of UWB Channels in Industrial Environments
  • 2005
  • Konferensbidrag (refereegranskat)abstract
    • Communication in industrial environments is an important scenario for ultra wideband (UWB) systems. The characteristics of this environment differ considerably from office environments, where most of the channel measurements reported in the literature are performed. In this paper, we present the results and analysis of UWB channel measurements in an industrial environment. We investigate both peer-to-peer non-line-of-sight (P-P NLOS) and base station NLOS (BS NLOS) scenarios. The measurements are performed in the frequency range 3.1 to 8 GHz, at distances 2-16 m, using a vector network analyzer in conjunction with virtual antenna arrays. From these measurements, we extract channel model parameters such as power delay profiles, pathloss exponents, rms delay spread and the percentage of energy captured by RAKE receivers with a finite number of fingers. In addition, Saleh- Valenzuela parameters such as ray and cluster power decay constants and distribution of cluster interarrival times are extracted.
  •  
2.
  • Khan, Muhammad Gufran, et al. (författare)
  • Non-Coherent Fourth-Order Detector for Impulse Radio Ultra Wideband Systems : Empirical Evaluation Using Channel Measurements
  • 2013
  • Ingår i: Wireless personal communications. - : Springer. - 0929-6212 .- 1572-834X. ; 68:1, s. 27-46
  • Tidskriftsartikel (refereegranskat)abstract
    • Low-complex and low-power non-coherent energy detectors (EDs) are interesting for low data rate impulse radio (IR) ultra wideband (UWB) systems, but suffer from a loss in performance compared to coherent receivers. The performance of an ED also strongly depends on the integration interval (window size) of the integrator and the window position. This paper presents a non-coherent fourth-order detector (FD) which can discriminate between Gaussian noise signals and non-Gaussian IR-UWB signals by directly estimating the fourth-order moment of the received signal. The performance of the detectors is evaluated using realistic channels measured in a corridor, an office and a laboratory environment. The results show that bit-error-rate (BER) performance of the proposed FD receiver is slightly better than the ED in low signal-to-noise ratio (SNR) region and its performance improves as the SNR increases. In addition, BER of the FD receiver is less sensitive to overestimation of the integration interval making it relatively robust to variations of the channel delay spread. Finally, a criteria for the selection of integration time of the proposed detector is suggested.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
konferensbidrag (1)
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Tufvesson, Fredrik (2)
Khan, Muhammad Gufra ... (2)
Kåredal, Johan (1)
Molisch, Andreas (1)
Claesson, Ingvar (1)
Nordberg, Jörgen (1)
visa fler...
Sällberg, Benny (1)
Ashraf, Asim A. (1)
visa färre...
Lärosäte
Lunds universitet (1)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Teknik (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy