SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Velikyan Irina 1966 ) ;pers:(Eriksson Barbro)"

Sökning: WFRF:(Velikyan Irina 1966 ) > Eriksson Barbro

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Eriksson, Olof, et al. (författare)
  • Species differences in pancreatic binding of DO3A-VS-Cys40-Exendin4
  • 2017
  • Ingår i: Acta Diabetologica. - : Springer Science and Business Media LLC. - 0940-5429 .- 1432-5233. ; 54:11, s. 1039-1045
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Radiolabeled Exendin-4 has been proposed as suitable imaging marker for pancreatic beta cell mass quantification mediated by Glucagon-like peptide-1 receptor (GLP-1R). However, noticeable species variations in basal pancreatic uptake as well as uptake reduction degree due to selective beta cell ablation were observed.METHODS: -Exendin4 Positron Emission Tomography (PET) in the same species. In vitro, ex vivo, and in vivo data formed the basis for calculating the theoretical in vivo contribution of each pancreatic compartment.RESULTS: -Exendin4.CONCLUSIONS: IPR as well as the exocrine GLP-1R density is the main determinants of the species variability in pancreatic uptake. Thus, the IPR in human is an important factor for assessing the potential of GLP-1R as an imaging biomarker for pancreatic beta cells.
  •  
2.
  • Ilan, Ezgi, et al. (författare)
  • Parametric Net Influx Rate Images of 68Ga-DOTATOC and 68Ga-DOTATATE : Quantitative Accuracy and Improved Image Contrast
  • 2017
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 58:5, s. 744-749
  • Tidskriftsartikel (refereegranskat)abstract
    • (68)Ga-DOTATOC and (68)Ga-DOTATATE are radiolabelled somatostatin analogs used for diagnosis of somatostatin receptor expressing neuroendocrine tumors (NETs) and SUV -measurements are suggested for treatment monitoring. However, changes in net-influx rate (Ki) may better reflect treatment effects than those of the SUV, and accordingly there is a need to compute parametric images showing Ki at the voxel level. The aim of this study was to evaluate parametric methods for computation of parametric Ki images by comparison to volume of interest based methods and to assess image contrast in terms of tumor-to-liver ratio.METHODS: Ten patients with metastatic NETs underwent a 45-min dynamic PET examination followed by whole-body PET/CT at 1 h post injection of (68)Ga-DOTATOC and (68)Ga-DOTATATE on consecutive days. Parametric Ki images were computed using a basis function method (BFM) implementation of the two tissue irreversible compartment model and the Patlak method using a descending aorta image-derived input function, and mean tumor Ki values were determined for 50% isocontour VOIs and compared to Ki values based on non-linear regression (NLR) of the whole-VOI time-activity curve. A subsample of healthy liver was delineated in the whole-body and Ki images and tumor-to-liver ratios were calculated in order to evaluate image contrast. Correlation and agreement between VOI-based and parametric Ki values were assessed using regression and Bland-Altman analysis.RESULTS: Correlation (R2) between NLR-based and parametric image-based (BFM) tumor Ki values was 0.98 (slope 0.81) and 0.97 (slope 0.88) for (68)Ga-DOTATOC and (68)Ga DOTATATE, respectively. For Patlak analysis, correlation between NLR-based and parametric based (Patlak) tumor Ki were 0.95 (slope 0.71) and 0.92 (slope 0.74) for (68)Ga-DOTATOC and (68)Ga-DOTATATE, respectively. There was no bias between NLR and parametric based Ki-values. Tumor-to-liver contrast was 1.6 and 2.0 times higher in the parametric BFM-Ki images, and 2.3 and 3.0 times in the Patlak images, than in the whole-body images for (68)Ga-DOTATOC and (68)Ga-DOTATATE, respectively.CONCLUSION: A high correlation and agreement between NLR- and parametric based Ki values was found, showing that parametric net influx rate images are quantitatively accurate. In addition, tumor-to-liver contrast was superior in the parametric Ki images compared to whole-body images both for (68)Ga-DOTATOC and (68)Ga DOTATATE.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy