SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Velikyan Irina 1966 ) ;pers:(Sörensen Jens)"

Sökning: WFRF:(Velikyan Irina 1966 ) > Sörensen Jens

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alhuseinalkhudhur, Ali, et al. (författare)
  • Human Epidermal Growth Factor Receptor 2-Targeting [68Ga]Ga-ABY-025 PET/CT Predicts Early Metabolic Response in Metastatic Breast Cancer.
  • 2023
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667. ; 64:9, s. 1364-1370
  • Tidskriftsartikel (refereegranskat)abstract
    • Imaging using the human epidermal growth factor receptor 2 (HER2)-binding tracer 68Ga-labeled ZHER2:2891-Cys-MMA-DOTA ([68Ga]Ga-ABY-025) was shown to reflect HER2 status determined by immunohistochemistry and in situ hybridization in metastatic breast cancer (MBC). This single-center open-label phase II study investigated how [68Ga]Ga-ABY-025 uptake corresponds to biopsy results and early treatment response in both primary breast cancer (PBC) planned for neoadjuvant chemotherapy and MBC. Methods: Forty patients with known positive HER2 status were included: 19 with PBC and 21 with MBC (median, 3 previous treatments). [68Ga]Ga-ABY-025 PET/CT, [18F]F-FDG PET/CT, and core-needle biopsies from targeted lesions were performed at baseline. [18F]F-FDG PET/CT was repeated after 2 cycles of therapy to calculate the directional change in tumor lesion glycolysis (Δ-TLG). The largest lesions (up to 5) were evaluated in all 3 scans per patient. SUVs from [68Ga]Ga-ABY-025 PET/CT were compared with the biopsied HER2 status and Δ-TLG by receiver operating characteristic analyses. Results: Trial biopsies were HER2-positive in 31 patients, HER2-negative in 6 patients, and borderline HER2-positive in 3 patients. The [68Ga]Ga-ABY-025 PET/CT cutoff SUVmax of 6.0 predicted a Δ-TLG lower than -25% with 86% sensitivity and 67% specificity in soft-tissue lesions (area under the curve, 0.74 [95% CI, 0.67-0.82]; P = 0.01). Compared with the HER2 status, this cutoff resulted in clinically relevant discordant findings in 12 of 40 patients. Metabolic response (Δ-TLG) was more pronounced in PBC (-71% [95% CI, -58% to -83%]; P < 0.0001) than in MBC (-27% [95% CI, -16% to -38%]; P < 0.0001), but [68Ga]Ga-ABY-025 SUVmax was similar in both with a mean SUVmax of 9.8 (95% CI, 6.3-13.3) and 13.9 (95% CI, 10.5-17.2), respectively (P = 0.10). In multivariate analysis, global Δ-TLG was positively associated with the number of previous treatments (P = 0.0004) and negatively associated with [68Ga]Ga-ABY-025 PET/CT SUVmax (P = 0.018) but not with HER2 status (P = 0.09). Conclusion: [68Ga]Ga-ABY-025 PET/CT predicted early metabolic response to HER2-targeted therapy in HER2-positive breast cancer. Metabolic response was attenuated in recurrent disease. [68Ga]Ga-ABY-025 PET/CT appears to provide an estimate of the HER2 expression required to induce tumor metabolic remission by targeted therapies and might be useful as an adjunct diagnostic tool.
  •  
2.
  • Alhuseinalkhudhur, Ali, et al. (författare)
  • Kinetic analysis of HER2-binding ABY-025 Affibody molecule using dynamic PET in patients with metastatic breast cancer
  • 2020
  • Ingår i: EJNMMI Research. - : SPRINGEROPEN. - 2191-219X. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: High expression of human epidermal growth factor receptor type 2 (HER2) represents an aggressive subtype of breast cancer. Anti-HER2 treatment requires a theragnostic approach wherein sufficiently high receptor expression in biopsy material is mandatory. Heterogeneity and discordance of HER2 expression between primary tumour and metastases, as well as within a lesion, present a complication for the treatment and require multiple biopsies. Molecular imaging using the HER2-targeting Affibody peptide ABY-025 radiolabelled with Ga-68-gallium for PET/CT is currently under investigation as a non-invasive tool for whole-body evaluation of metastatic HER2 expression. Initial studies demonstrated a high correlation between Ga-68-ABY-025 standardized uptake values (SUVs) and histopathology. However, detecting small liver lesions might be compromised by high background uptake. This study aimed to explore the applicability of kinetic modelling and parametric image analysis for absolute quantification of Ga-68-ABY-025 uptake and HER2-receptor expression and how that relates to static SUVs.Methods: Dynamic Ga-68-ABY-025 PET of the upper abdomen was performed 0-45 min post-injection in 16 patients with metastatic breast cancer. Five patients underwent two examinations to test reproducibility. Parametric images of tracer delivery (K-1) and irreversible binding (K-i) were created with an irreversible two-tissue compartment model and Patlak graphical analysis using an image-derived input function from the descending aorta. A volume of interest (VOI)-based analysis was performed to validate parametric images. SUVs were calculated from 2 h and 4 h post-injection static whole-body images and compared to K-i.Results: Characterization of HER2 expression in smaller liver metastases was improved using parametric images. K-i values from parametric images agreed very well with VOI-based gold standard (R-2 > 0.99, p < 0.001). SUVs of metastases at 2 h and 4 h post-injection were highly correlated with K-i values from both the two-tissue compartment model and Patlak method (R-2 = 0.87 and 0.95, both p < 0.001). Ga-68-ABY-025 PET yielded high test-retest reliability (relative repeatability coefficient for Patlak 30% and for the two-tissue compartment model 47%).Conclusion: Ga-68-ABY-025 binding in HER2-positive metastases was well characterized by irreversible two-tissue compartment model wherein K-i highly correlated with SUVs at 2 and 4 h. Dynamic scanning with parametric image formation can be used to evaluate metastatic HER2 expression accurately.
  •  
3.
  •  
4.
  • Lindström, Elin, et al. (författare)
  • Regularized reconstruction of digital time-of-flight Ga-68-PSMA-11 PET/CT for the detection of recurrent disease in prostate cancer patients
  • 2019
  • Ingår i: Theranostics. - : Ivyspring International Publisher. - 1838-7640. ; 9:12, s. 3476-3484
  • Tidskriftsartikel (refereegranskat)abstract
    • Accurate localization of recurrent prostate cancer (PCa) is critical, especially if curative therapy is intended. With the aim to optimize target-to-background uptake ratio in Ga-68-PSMA-11 PET, we investigated the image quality and quantitative measures of regularized reconstruction by block-sequential regularized expectation maximization (BSREM).Methods: The study encompassed retrospective reconstruction and analysis of 20 digital time-of-flight (TOF) PET/CT examinations acquired 60 min post injection of 2 MBq/kg of Ga-68-PSMA-11 in PCa patients with biochemical relapse after primary treatment. Reconstruction by ordered-subsets expectation maximization (OSEM; 3 iterations, 16 subsets, 5 mm gaussian postprocessing filter) and BSREM (beta-values of 100-1600) were used, both including TOF and point spread function (PSF) recovery. Background variability (BV) was measured by placing a spherical volume of interest in the right liver lobe and defined as the standard deviation divided by the mean standardized uptake value (SUV). The image quality was evaluated in terms of signal-to-noise ratio (SNR) and signal-to-background ratio (SBR), using SUVmax of the lesions. A visual assessment was performed by four observers.Results:OSEM reconstruction produced images with a BV of 15%, whereas BSREM with a beta-value above 300 resulted in lower BVs than OSEM (36% with beta 100, 8% with beta 1300). Decreasing the acquisition duration from 2 to 1 and 0.5 min per bed position increased BV for both reconstruction methods, although BSREM with beta-values equal to or higher than 800 and 1200, respectively, kept the BV below 15%. In comparison of BSREM with OSEM, the mean SNR improved by 25 to 66% with an increasing beta-value in the range of 200-1300, whereas the mean SBR decreased with an increasing beta-value, ranging from 0 to 125% with a beta-value of 100 and 900, respectively. Decreased acquisition duration resulted in beta-values of 800 to 1000 and 1200 to 1400 for 1 and 0.5 min per bed position, respectively, producing improved image quality measures compared with OSEM at a full acquisition duration of 2 min per bed position. The observer study showed a slight overall preference for BSREM beta 900 although the interobserver variability was high.Conclusion:BSREM image reconstruction with beta-values in the range of 400-900 resulted in lower BV and similar or improved SNR and SBR in comparison with OSEM.
  •  
5.
  • Regula, Naresh, et al. (författare)
  • Carbon Flux as a Measure of Prostate Cancer Aggressiveness : [11C]-Acetate PET/CT
  • 2020
  • Ingår i: International Journal of Medical Sciences. - : Ivyspring International Publisher. - 1449-1907. ; 17:2, s. 214-223
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Dynamic [11C]-acetate positron emission tomography (PET) can be used to study tissue perfusion and carbon flux simultaneously. In this study, the feasibility of the quantification of prostate cancer aggressiveness using parametric methods assessing [11C]-acetate kinetics was investigated in prostate cancer subjects. The underlying uptake mechanism correlated with [11C]-acetate influx and efflux measured in real-time in vitro in cell culture.Methods: Twenty-one patients with newly diagnosed low-to-moderate risk prostate cancer underwent magnetic resonance imaging (MRI) and dynamic [11C]-acetate PET/CT examinations of the pelvis. Parametric images of K1 (extraction × perfusion), k2 (oxidative metabolism) and VT (=K1/k2, anabolic metabolism defined as carbon retention) were constructed using a one-tissue compartment model with an arterial input function derived from pelvic arteries. Regions of interest (ROIs) of the largest cancer lesion in each patient and normal prostate tissue were drawn using information from MRI (T2 and DWI images), biopsy results, and post-surgical histopathology of whole prostate sections (n=7). In vitro kinetics of [11C]-acetate were studied on DU145 andPC3 cell lines using LigandTracer® White equipment for the measurement of the radioactivity uptake in real-time at 37°C.Results: Mean prostate specific antigen (PSA) was 8.33±3.92 ng/mL and median Gleason Sum 6 (range 5-7). K1,VT and standardized uptake values (SUVs) were significantly higher in cancerous prostate tissues compared to normal ones for all patients (p<0.001), while k2 was not (p=0.26). PSA values correlated to early SUVs (r=0.50,p=0.02) and K1 (r=0.48, p=0.03). Early and late SUVs correlated to VT (r>0.76, p<0.001) and K1 (r>0.64,p<0.005). In vitro studies demonstrated higher extraction and retention (p<0.01) of [11C]-acetate in the more aggressive PC3 cells.Conclusion: Parametric images could be used to visualize the [11C]-acetate kinetics of the prostate cancer exhibiting elevated extraction associated with the cancer aggressiveness. The influx rate of [11C]-acetate studied in cell culture also showed dependence on the cancer aggressiveness associated with elevated lipogenesis. Dynamic [11C]-acetate/PET demonstrated potential for prostate cancer aggressiveness estimation using parametric-based K1 and VT values.
  •  
6.
  • Regula, Naresh, et al. (författare)
  • Comparison of 68Ga-PSMA-11 PET/CT with 11C-acetate PET/CT in re-staging of prostate cancer relapse
  • 2020
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Positron emission tomography (PET) imaging is used to localize recurrent disease in prostate cancer (PCa). The tracer 68Ga-PSMA-11 visualizes lesions overexpressing prostate-specific membrane antigen (PSMA), while 11C-acetate visualizes lesions with increased anabolic metabolism. The aim of this study was to compare the performance of PSMA-PET and acetate-PET in re-staging patients with biochemical relapse. Thirty PCa patients with prostate-specific antigen (PSA) relapse after primary curative therapy were prospectively evaluated. PET/CT examinations using 11C-acetate and 68Ga-PSMA-11 were performed. Identified lesions were categorized according to anatomical location and PET measurements were correlated with PSA at time of scan. Tumour lesions showed higher semi-quantitative uptake values on PSMA-PET than acetate-PET. PSMA-PET identified more lesions in 11 patients, fewer lesions in eight patients, and identical number of lesions in 11 patients. This study indicates better diagnostic performance of PSMA-PET, particularly in detecting lymph node (81% vs 60%, p=0.02) and bone metastasis (95% vs 61%, p=0.0001) compared to acetate-PET. However, 38% of PSMA-expressing metastases appear to be metabolically inactive and 15% of metabolically active metastases lack PSMA expression. Addition of PET with a metabolic tracer, such as 11C-acetate, might be beneficial before making treatment decisions.
  •  
7.
  • Regula, Naresh Kumar, et al. (författare)
  • Comparison of Ga-68-PSMA PET/CT with fluoride PET/CT for detection of bone metastatic disease in prostate cancer
  • 2022
  • Ingår i: European Journal of Hybrid Imaging. - : Springer Nature. - 2510-3636. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background F-18-NaF positron emission tomography/computed tomography (fluoride PET/CT) is considered the most sensitive technique to detect bone metastasis in prostate cancer (PCa). Ga-68-PSMA-11 (PSMA) PET/CT is increasingly used for staging of PCa. This study primarily aimed to compare the diagnostic performance of fluoride PET/CT and gallium-based PSMA PET/CT in identifying bone metastasis followed by a comparison of PSMA PET/CT with contrast-enhanced CT (CE-CT) in identifying soft tissue lesions as a secondary objective. Methods Twenty-eight PCa patients with high suspicion of disseminated disease following curative treatment were prospectively evaluated. PET/CT examinations using fluoride and PSMA were performed. All suspicious bone lesions were counted, and the tracer uptake was measured as standardized uptake values (SUV) for both tracers. In patients with multiple findings, ten bone lesions with highest SUVmax were selected from which identical lesions from both scans were considered for direct comparison of SUVmax. Soft tissue findings of local and lymph node lesions from CE-CT were compared with PSMA PET/CT. Results Both scans were negative for bone lesions in 7 patients (25%). Of 699 lesions consistent with skeletal metastasis in 21 patients on fluoride PET/CT, PSMA PET/CT identified 579 lesions (83%). In 69 identical bone lesions fluoride PET/CT showed significantly higher uptake (mean SUVmax: 73.1 +/- 36.8) compared to PSMA PET/CT (34.5 +/- 31.4; p < 0.001). Compared to CE-CT, PSMA PET/CT showed better diagnostic performance in locating local (96% vs 61%, p = 0.004) and lymph node (94% vs 46%, p < 0.001) metastasis. Conclusion In this prospective comparative study, PSMA PET/CT detected the majority of bone lesions that were positive on fluoride PET/CT. Further, this study indicates better diagnostic performance of PSMA PET/CT to locate soft tissue lesions compared to CE-CT.
  •  
8.
  • Sandberg, Dan T, et al. (författare)
  • Intra-image referencing for simplified assessment of HER2-expression in breast cancer metastases using the Affibody molecule ABY-025 with PET and SPECT.
  • 2017
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 44:8, s. 1337-1346
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: In phase I/II-studies radiolabelled ABY-025 Affibody molecules identified human epidermal growth factor receptor 2 (HER2) expression in breast cancer metastases using PET and SPECT imaging. Here, we wanted to investigate the utility of a simple intra-image normalization using tumour-to-reference tissue-ratio (T/R) as a HER2 status discrimination strategy to overcome potential issues related to cross-calibration of scanning devices.METHODS: Twenty-three women with pre-diagnosed HER2-positive/negative metastasized breast cancer were scanned with [(111)In]-ABY-025 SPECT/CT (n = 7) or [(68)Ga]-ABY-025 PET/CT (n = 16). Uptake was measured in all metastases and in normal spleen, lung, liver, muscle, and blood pool. Normal tissue uptake variation and T/R-ratios were established for various time points and for two different doses of injected peptide from a total of 94 whole-body image acquisitions. Immunohistochemistry (IHC) was used to verify HER2 expression in 28 biopsied metastases. T/R-ratios were compared to IHC findings to establish the best reference tissue for each modality and each imaging time-point. The impact of shed HER2 in serum was investigated.RESULTS: Spleen was the best reference tissue across modalities, followed by blood pool and lung. Spleen-T/R was highly correlated to PET SUV in metastases after 2 h (r = 0.96, P < 0.001) and reached an accuracy of 100% for discriminating IHC HER2-positive and negative metastases at 4 h (PET) and 24 h (SPECT) after injection. In a single case, shed HER2 resulted in intense tracer retention in blood. In the remaining patients shed HER2 was elevated, but without significant impact on ABY-025 biodistribution.CONCLUSION: T/R-ratios using spleen as reference tissue accurately quantify HER2 expression with radiolabelled ABY-025 imaging in breast cancer metastases with SPECT and PET. Tracer binding to shed HER2 in serum might affect quantification in the extreme case.
  •  
9.
  • Velikyan, Irina, 1966-, et al. (författare)
  • Diagnostic HER2-binding radiopharmaceutical, [Ga-68]Ga-ABY-025, for routine clinical use in breast cancer patients
  • 2019
  • Ingår i: American Journal of Nuclear Medicine and Molecular Imaging. - : E-CENTURY PUBLISHING CORP. - 2160-8407. ; 9:1, s. 12-23
  • Tidskriftsartikel (refereegranskat)abstract
    • [Ga-68]Ga-ABY-025/PET-CT targeting human epidermal growth factor receptor type 2 (HER2) has demonstrated its potential clinical value for the detection and quantification of HER2 in a phase I clinical study with breast cancer patients. Previously, the radiopharmaceutical was prepared manually, however larger scale of multicenter clinical trials and routine healthcare requires automation of the production process to limit the operator radiation dose, improve tracer manufacturing robustness, and provide on-line documentation for good manufacturing practice (GMP) compliance. The production of [Ga-68]Ga-ABY-025 was implemented on the Modular-Lab PharmTrace synthesis platform (Eckert & Ziegler) and disposable cassettes were developed. Pharmaceutical grade Ge-68/Ga-68 generator (GalliaPharm (R)) was used in the study. The active pharmaceutical ingredient starting material ABY-025 (GMP grade) was provided by Affibody AB. The patient examinations were conducted using a Discovery MI PET/CT scanner (20 cm FOV, GE Healthcare). Reproducible and GMP compliant fully automated production of [Ga-68]Ga-ABY-025 was developed. The radiochemical purity of the product was 98.7 +/- 0.6% with total peptide content of 315 +/- 15 mu g (n = 3). Radionuclidic purity, sterility, endotoxin content, residual solvent content, and sterile filter integrity were controlled and met acceptance criteria. The product was stable at ambient temperature for at least 2 h. The primary tumor and metastasis were detected with SUVmax values of 8.3 and 16.0, respectively. Automated production of [Ga-68]Ga-ABY-025 was established and the process was validated enabling standardized multicenter phase II and III clinical trials and routine clinical use. Patient examinations conformed to the radiopharmaceutical biodistribution observed in the previous phase I study.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy