Sökning: WFRF:(Vikinge Trine)
> Konferensbidrag >
Blood plasma coagul...
Blood plasma coagulation studied by surface plasmon resonance
-
- Vikinge, Trine P. (författare)
- Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
-
- Hansson, Kenny (författare)
- Linköpings universitet,Institutionen för fysik, kemi och biologi,Tekniska högskolan
-
- Benesch, Johan (författare)
- Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
-
visa fler...
-
- Johansen, Knut (författare)
- Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
-
- Rånby, Mats (författare)
- Linköpings universitet,Östergötlands Läns Landsting,Klinisk kemi,Hälsouniversitetet
-
- Lindahl, Tomas (författare)
- Linköpings universitet,Klinisk kemi,Hälsouniversitetet
-
- Lundström, Ingemar (författare)
- Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
-
- Tengvall, Pentti (författare)
- Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
-
visa färre...
-
(creator_code:org_t)
- SPIE - International Society for Optical Engineering, 1999
- 1999
- Engelska.
-
Ingår i: BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS. - : SPIE - International Society for Optical Engineering. ; , s. 107-114
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A surface plasmon resonance (SPR) apparatus was used to investigate blood plasma coagulation in real-time as a function of thromboplastin and heparin concentrations. The physical reason for the SPR signal observed is discussed and 3 different models are proposed. The response curves were analyzed by multivariable curve fitting followed by feature extraction. Interesting parameters of the sigmoid curves were lag time, slope and maximum response. When thromboplastin concentrations were increased, the lag-time decreased and the slope of the curve increased. A prolonged clotting time was mostly followed by increased maximum response, with exception for samples with no or very little thromboplastin added. High heparin concentrations changed the clotting kinetics, as seen from the lag-time vs. slope relation. Atomic force microscopy (AFM) pictures of sensor surfaces dried after completed clotting, revealed differences in fibrin network structures as a function of thromboplastin concentration, and fiber thickness increased with lower thromboplastin concentration. The results correlate well with present common methods.
Nyckelord
- surface plasmon resonance (SPR); blood plasma coagulation; atomic force microscopy (AFM)
- TECHNOLOGY
- TEKNIKVETENSKAP
Publikations- och innehållstyp
- ref (ämneskategori)