SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Vikinge Trine)
 

Sökning: WFRF:(Vikinge Trine) > Konferensbidrag > Blood plasma coagul...

Blood plasma coagulation studied by surface plasmon resonance

Vikinge, Trine P. (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Hansson, Kenny (författare)
Linköpings universitet,Institutionen för fysik, kemi och biologi,Tekniska högskolan
Benesch, Johan (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
visa fler...
Johansen, Knut (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Rånby, Mats (författare)
Linköpings universitet,Östergötlands Läns Landsting,Klinisk kemi,Hälsouniversitetet
Lindahl, Tomas (författare)
Linköpings universitet,Klinisk kemi,Hälsouniversitetet
Lundström, Ingemar (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
Tengvall, Pentti (författare)
Linköpings universitet,Tillämpad Fysik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 1999
1999
Engelska.
Ingår i: BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS. - : SPIE - International Society for Optical Engineering. ; , s. 107-114
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • A surface plasmon resonance (SPR) apparatus was used to investigate blood plasma coagulation in real-time as a function of thromboplastin and heparin concentrations. The physical reason for the SPR signal observed is discussed and 3 different models are proposed. The response curves were analyzed by multivariable curve fitting followed by feature extraction. Interesting parameters of the sigmoid curves were lag time, slope and maximum response. When thromboplastin concentrations were increased, the lag-time decreased and the slope of the curve increased. A prolonged clotting time was mostly followed by increased maximum response, with exception for samples with no or very little thromboplastin added. High heparin concentrations changed the clotting kinetics, as seen from the lag-time vs. slope relation. Atomic force microscopy (AFM) pictures of sensor surfaces dried after completed clotting, revealed differences in fibrin network structures as a function of thromboplastin concentration, and fiber thickness increased with lower thromboplastin concentration. The results correlate well with present common methods.

Nyckelord

surface plasmon resonance (SPR); blood plasma coagulation; atomic force microscopy (AFM)
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy