SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wåhlin Anders) ;lar1:(liu)"

Sökning: WFRF:(Wåhlin Anders) > Linköpings universitet

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ambarki, Khalid, et al. (författare)
  • Brain ventricular size in healthy elderly: comparison between evans index and volume measurement.
  • 2010
  • Ingår i: Neurosurgery. - : Lippincott Williams & Wilkins. - 0148-396X .- 1524-4040. ; 67:1, s. 94-99
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: A precise definition of ventricular enlargement is important in the diagnosis of hydrocephalus as well as in assessing central atrophy. The Evans index (EI), a linear ratio between the maximal frontal horn width and the cranium diameter, has been extensively used as an indirect marker of ventricular volume (VV). With modern imaging techniques, brain volume can be directly measured. OBJECTIVE: To determine reference values of intracranial volumes in healthy elderly individuals and to correlate volumes with the EI. METHODS: Magnetic resonance imaging (3 T) was performed in 46 healthy white elderly subjects (mean age +/- standard deviation, 71 +/- 6 years) and in 20 patients (74 +/- 7 years) with large ventricles according to visual inspection. VV, relative VV (RVV), and EI were assessed. Ventricular dilation was defined using VV and EI by a value above the 95th percentile range for healthy elderly individuals. RESULTS: In healthy elderly subjects, we found VV = 37 +/- 18 mL, RVV = 2.47 +/- 1.17%, and EI = 0.281 +/- 0.027. Including the patients, there was a strong correlation between EI and VV (R = 0.94) as well as between EI and RVV (R = 0.95). However, because of a wide 95% prediction interval (VV: +/-45 mL; RVV: +/- 2.54%), EI did not give a sufficiently good estimate of VV and RVV. CONCLUSION: VV (or RVV) and the EI reflect different properties. The exclusive use of EI in clinical studies as a marker of enlarged ventricles should be questioned. We suggest that the definition of dilated ventricles in white elderly individuals be defined as VV >77 mL or RVV >4.96 %. Future studies should compare intracranial volumes with clinical characteristics and prognosis.
  •  
2.
  • Ambarki, Khalid, et al. (författare)
  • Evaluation of Automatic Measurement of the Intracranial Volume Based on Quantitative MR Imaging
  • 2012
  • Ingår i: American Journal of Neuroradiology. - : American Society of Neuroradiology. - 0195-6108 .- 1936-959X. ; 33:10, s. 1951-1956
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: Brain size is commonly described in relation to ICV, whereby accurate assessment of this quantity is fundamental. Recently, an optimized MR sequence (QRAPMASTER) was developed for simultaneous quantification of T1, T2, and proton density. ICV can be measured automatically within minutes from QRAPMASTER outputs and a dedicated software, SyMRI. Automatic estimations of ICV were evaluated against the manual segmentation. MATERIALS AND METHODS: In 19 healthy subjects, manual segmentation of ICV was performed by 2 neuroradiologists (Obs1, Obs2) by using QBrain software and conventional T2-weighted images. The automatic segmentation from the QRAPMASTER output was performed by using SyMRI. Manual corrections of the automatic segmentation were performed (corrected-automatic) by Obs1 and Obs2, who were blinded from each other. Finally, the repeatability of the automatic method was evaluated in 6 additional healthy subjects, each having 6 repeated QRAPMASTER scans. The time required to measure ICV was recorded. RESULTS: No significant difference was found between reference and automatic (and corrected-automatic) ICV (P greater than .25). The mean difference between the reference and automatic measurement was -4.84 +/- 19.57 mL (or 0.31 +/- 1.35%). Mean differences between the reference and the corrected-automatic measurements were -0.47 +/- 17.95 mL (-0.01 +/- 1.24%) and -1.26 +/- 17.68 mL (-0.06 +/- 1.22%) for Obs1 and Obs2, respectively. The repeatability errors of the automatic and the corrected-automatic method were less than1%. The automatic method required 1 minute 11 seconds (SD = 12 seconds) of processing. Adding manual corrections required another 1 minute 32 seconds (SD = 38 seconds). CONCLUSIONS: Automatic and corrected-automatic quantification of ICV showed good agreement with the reference method. SyMRI software provided a fast and reproducible measure of ICV.
  •  
3.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy