SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wåhlin Anders) ;pers:(Ambarki Khalid)"

Sökning: WFRF:(Wåhlin Anders) > Ambarki Khalid

  • Resultat 1-10 av 27
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ambarki, Khalid, et al. (författare)
  • Accuracy of Parenchymal Cerebral Blood Flow Measurements Using Pseudocontinuous Arterial Spin-labeling in Healthy Volunteers
  • 2015
  • Ingår i: American Journal of Neuroradiology. - 0195-6108 .- 1936-959X. ; 36:10, s. 1816-1821
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: The arterial spin-labeling method for CBF assessment is widely available, but its accuracy is not fully established. We investigated the accuracy of a whole-brain arterial spin-labeling technique for assessing the mean parenchymal CBF and the effect of aging in healthy volunteers. Phase-contrast MR imaging was used as the reference method. MATERIALS AND METHODS: Ninety-two healthy volunteers were included: 49 young (age range, 20-30 years) and 43 elderly (age range, 65-80 years). Arterial spin-labeling parenchymal CBF values were averaged over the whole brain to quantify the mean pCBF(ASL) value. Total. CBF was assessed with phase-contrast MR imaging as the sum of flows in the internal carotid and vertebral arteries, and subsequent division by brain volume returned the pCBF(PCMRI) value. Accuracy was considered as good as that of the reference method if the systematic difference was less than 5 mL/min/100 g of brain tissue and if the 95% confidence intervals were equal to or better than +/- 10 mL/min/100 g. RESULTS: pCBF(ASL) correlated to pCBF(PCMRI) (r = 0.73; P < .001). Significant differences were observed between the pCBF(ASL) and pCBF(PCMRI) values in the young (P = .001) and the elderly (P < .001) volunteers. The systematic differences (mean 2 standard deviations) were -4 +/- 14 mL/min/100 g in the young subjects and 6 +/- 12 mL/min/100 g in the elderly subjects. Young subjects showed higher values than the elderly subjects for pCBF(PCMRI) (young, 57 +/- 8 mL/min/100 g; elderly, 54 +/- 7 mL/min/100 g; P = .05) and pCBF(ASL) (young, 61 +/- 10 mL/min/100 g; elderly, 48 +/- 10 mL/min/100 g; P < .001). CONCLUSIONS: The limits of agreement were too wide for the arterial spin-labeling method to be considered satisfactorily accurate, whereas the systematic overestimation in the young subjects and underestimation in the elderly subjects were close to acceptable. The age-related decrease in parenchymal CBF was augmented in arterial spin-labeling compared with phase-contrast MR imaging.
  •  
2.
  • Ambarki, Khalid, et al. (författare)
  • Blood flow of ophthalmic artery in healthy individuals determined by phase-contrast magnetic resonance imaging
  • 2013
  • Ingår i: Investigative Ophthalmology and Visual Science. - : Association for Research in Vision and Ophthalmology (ARVO). - 0146-0404 .- 1552-5783. ; 54:4, s. 2738-2745
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: Recent development of magnetic resonance imaging (MRI) offers new possibilities to assess ocular blood flow. This prospective study evaluates the feasibility of phase-contrast MRI (PCMRI) to measure flow rate in the ophthalmic artery (OA) and establish reference values in healthy young (HY) and elderly (HE) subjects.METHODS: Fifty HY subjects (28 females, 21-30 years of age) and 44 HE (23 females, 64-80 years of age) were scanned on a 3-Tesla MR system. The PCMRI sequence had a spatial resolution of 0.35 mm per pixel, with the measurement plan placed perpendicularly to the OA. Mean flow rate (Qmean), resistive index (RI), and arterial volume pulsatility of OA (ΔVmax) were measured from the flow rate curve. Accuracy of PCMRI measures was investigated using a vessel-phantom mimicking the diameter and the flow rate range of the human OA.RESULTS: Flow rate could be assessed in 97% of the OAs. Phantom investigations showed good agreement between the reference and PCMRI measurements with an error of <7%. No statistical difference was found in Qmean between HY and HE individuals (HY: mean ± SD = 10.37 ± 4.45 mL/min; HE: 10.81 ± 5.15 mL/min, P = 0.655). The mean of ΔVmax (HY: 18.70 ± 7.24 μL; HE: 26.27 ± 12.59 μL, P < 0.001) and RI (HY: 0.62 ± 0.08; HE: 0.67 ± 0.1, P = 0.012) were significantly different between HY and HE.CONCLUSIONS: This study demonstrated that the flow rate of OA can be quantified using PCMRI. There was an age difference in the pulsatility parameters; however, the mean flow rate appeared independent of age. The primary difference in flow curves between HE and HY was in the relaxation phase of the systolic peak.
  •  
3.
  • Ambarki, Khalid, et al. (författare)
  • Brain ventricular size in healthy elderly: comparison between evans index and volume measurement.
  • 2010
  • Ingår i: Neurosurgery. - : Lippincott Williams & Wilkins. - 0148-396X .- 1524-4040. ; 67:1, s. 94-99
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: A precise definition of ventricular enlargement is important in the diagnosis of hydrocephalus as well as in assessing central atrophy. The Evans index (EI), a linear ratio between the maximal frontal horn width and the cranium diameter, has been extensively used as an indirect marker of ventricular volume (VV). With modern imaging techniques, brain volume can be directly measured. OBJECTIVE: To determine reference values of intracranial volumes in healthy elderly individuals and to correlate volumes with the EI. METHODS: Magnetic resonance imaging (3 T) was performed in 46 healthy white elderly subjects (mean age +/- standard deviation, 71 +/- 6 years) and in 20 patients (74 +/- 7 years) with large ventricles according to visual inspection. VV, relative VV (RVV), and EI were assessed. Ventricular dilation was defined using VV and EI by a value above the 95th percentile range for healthy elderly individuals. RESULTS: In healthy elderly subjects, we found VV = 37 +/- 18 mL, RVV = 2.47 +/- 1.17%, and EI = 0.281 +/- 0.027. Including the patients, there was a strong correlation between EI and VV (R = 0.94) as well as between EI and RVV (R = 0.95). However, because of a wide 95% prediction interval (VV: +/-45 mL; RVV: +/- 2.54%), EI did not give a sufficiently good estimate of VV and RVV. CONCLUSION: VV (or RVV) and the EI reflect different properties. The exclusive use of EI in clinical studies as a marker of enlarged ventricles should be questioned. We suggest that the definition of dilated ventricles in white elderly individuals be defined as VV >77 mL or RVV >4.96 %. Future studies should compare intracranial volumes with clinical characteristics and prognosis.
  •  
4.
  • Ambarki, Khalid, et al. (författare)
  • Evaluation of Automatic Measurement of the Intracranial Volume Based on Quantitative MR Imaging
  • 2012
  • Ingår i: American Journal of Neuroradiology. - : American Society of Neuroradiology. - 0195-6108 .- 1936-959X. ; 33:10, s. 1951-1956
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: Brain size is commonly described in relation to ICV, whereby accurate assessment of this quantity is fundamental. Recently, an optimized MR sequence (QRAPMASTER) was developed for simultaneous quantification of T1, T2, and proton density. ICV can be measured automatically within minutes from QRAPMASTER outputs and a dedicated software, SyMRI. Automatic estimations of ICV were evaluated against the manual segmentation. MATERIALS AND METHODS: In 19 healthy subjects, manual segmentation of ICV was performed by 2 neuroradiologists (Obs1, Obs2) by using QBrain software and conventional T2-weighted images. The automatic segmentation from the QRAPMASTER output was performed by using SyMRI. Manual corrections of the automatic segmentation were performed (corrected-automatic) by Obs1 and Obs2, who were blinded from each other. Finally, the repeatability of the automatic method was evaluated in 6 additional healthy subjects, each having 6 repeated QRAPMASTER scans. The time required to measure ICV was recorded. RESULTS: No significant difference was found between reference and automatic (and corrected-automatic) ICV (P greater than .25). The mean difference between the reference and automatic measurement was -4.84 +/- 19.57 mL (or 0.31 +/- 1.35%). Mean differences between the reference and the corrected-automatic measurements were -0.47 +/- 17.95 mL (-0.01 +/- 1.24%) and -1.26 +/- 17.68 mL (-0.06 +/- 1.22%) for Obs1 and Obs2, respectively. The repeatability errors of the automatic and the corrected-automatic method were less than1%. The automatic method required 1 minute 11 seconds (SD = 12 seconds) of processing. Adding manual corrections required another 1 minute 32 seconds (SD = 38 seconds). CONCLUSIONS: Automatic and corrected-automatic quantification of ICV showed good agreement with the reference method. SyMRI software provided a fast and reproducible measure of ICV.
  •  
5.
  • Ambarki, Khalid, et al. (författare)
  • MR imaging of brain volumes : evaluation of a fully automatic software
  • 2011
  • Ingår i: American Journal of Neuroradiology. - 0195-6108 .- 1936-959X. ; 32:2, s. 408-412
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: Automatic assessment of brain volumes is needed in researchand clinical practice. Manual tracing is still the criterionstandard but is time-consuming. It is important to validatethe automatic tools to avoid the problems of clinical studiesdrawing conclusions on the basis of brain volumes estimatedwith methodologic errors. The objective of this study was toevaluate a new commercially available fully automatic softwarefor MR imaging of brain volume assessment. Automatic and expertmanual brain volumes were compared. MATERIALS AND METHODS: MR imaging (3T, axial T2 and FLAIR) was performed in 41 healthyelderly volunteers (mean age, 70 ± 6 years) and 20 patientswith hydrocephalus (mean age, 73 ± 7 years). The softwareQBrain was used to manually and automatically measure the followingbrain volumes: ICV, BTV, VV, and WMHV. The manual method hasbeen previously validated and was used as the reference. Agreementbetween the manual and automatic methods was evaluated by usinglinear regression and Bland-Altman plots. RESULTS: There were significant differences between the automatic andmanual methods regarding all volumes. The mean differences wereICV = 49 ± 93 mL (mean ± 2SD, n = 61), BTV = 11± 70 mL, VV = –6 ± 10 mL, and WMHV = 2.4± 9 mL. The automatic calculations of brain volumes tookapproximately 2 minutes per investigation. CONCLUSIONS: The automatic tool is promising and provides rapid assessmentof brain volumes. However, the software needs improvement beforeit is incorporated into research or daily use. Manual segmentationremains the reference method.
  •  
6.
  • Dunås, Tora, et al. (författare)
  • A Stereotactic Probabilistic Atlas for the Major Cerebral Arteries
  • 2017
  • Ingår i: Neuroinformatics. - : Springer Science and Business Media LLC. - 1539-2791 .- 1559-0089. ; 15:1, s. 101-110
  • Tidskriftsartikel (refereegranskat)abstract
    • Improved whole brain angiographic and velocity-sensitive MRI is pushing the boundaries of noninvasively obtained cerebral vascular flow information. The complexity of the information contained in such datasets calls for automated algorithms and pipelines, thus reducing the need of manual analyses by trained radiologists. The objective of this work was to lay the foundation for such automated pipelining by constructing and evaluating a probabilistic atlas describing the shape and location of the major cerebral arteries. Specifically, we investigated how the implementation of a non-linear normalization into Montreal Neurological Institute (MNI) space improved the alignment of individual arterial branches. In a population-based cohort of 167 subjects, age 64-68 years, we performed 4D flow MRI with whole brain volumetric coverage, yielding both angiographic and anatomical data. For each subject, sixteen cerebral arteries were manually labeled to construct the atlas. Angiographic data were normalized to MNI space using both rigid-body and non-linear transformations obtained from anatomical images. The alignment of arterial branches was significantly improved by the non-linear normalization (p < 0.001). Validation of the atlas was based on its applicability in automatic arterial labeling. A leave-one-out validation scheme revealed a labeling accuracy of 96 %. Arterial labeling was also performed in a separate clinical sample (n = 10) with an accuracy of 92.5 %. In conclusion, using non-linear spatial normalization we constructed an artery-specific probabilistic atlas, useful for cerebral arterial labeling.
  •  
7.
  • Dunås, Tora, et al. (författare)
  • Automatic labeling of cerebral arteries in magnetic resonance angiography
  • 2016
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - : Springer Science and Business Media LLC. - 0968-5243 .- 1352-8661. ; 29:1, s. 39-47
  • Tidskriftsartikel (refereegranskat)abstract
    • In order to introduce 4D flow magnetic resonance imaging (MRI) as a standard clinical instrument for studying the cerebrovascular system, new and faster postprocessing tools are necessary. The objective of this study was to construct and evaluate a method for automatic identification of individual cerebral arteries in a 4D flow MRI angiogram. Forty-six elderly individuals were investigated with 4D flow MRI. Fourteen main cerebral arteries were manually labeled and used to create a probabilistic atlas. An automatic atlas-based artery identification method (AAIM) was developed based on vascular-branch extraction and the atlas was used for identification. The method was evaluated by comparing automatic with manual identification in 4D flow MRI angiograms from 67 additional elderly individuals. Overall accuracy was 93 %, and internal carotid artery and middle cerebral artery labeling was 100 % accurate. Smaller and more distal arteries had lower accuracy; for posterior communicating arteries and vertebral arteries, accuracy was 70 and 89 %, respectively. The AAIM enabled fast and fully automatic labeling of the main cerebral arteries. AAIM functionality provides the basis for creating an automatic and powerful method to analyze arterial cerebral blood flow in clinical routine.
  •  
8.
  • Dunås, Tora, et al. (författare)
  • Towards Automatic Identification of Cerebral Arteries in 4D Flow MRI
  • 2015
  • Ingår i: 16th Nordic-Baltic Conference on Biomedical Engineering. - Cham : Springer International Publishing. - 9783319129662 - 9783319129679 ; , s. 40-43
  • Konferensbidrag (refereegranskat)abstract
    • 4D flow MRI is a powerful imaging technique which provides an angiographic image with information about blood flow in a large volume, time resolved over the cardiac cycle, in a short imaging time. This study aims to develop an automatic method for identification of cerebral arteries. The proposed method is based on an atlas of twelve arteries, developed from 4D flow MRI of 25 subjects. The atlas was constructed by normalizing all images to MNI-space, manually identifying the arteries and creating an average over the volume. The identification is done by extracting a vascular skeleton from the image, transforming it to MNI-space, labeling it with the atlas and transforming it back to subject space. The method was evaluated on a pilot cohort of 8 subjects. The rate of correctly identified arteries was 97%.
  •  
9.
  • Eklund, Anders, et al. (författare)
  • The Pressure Difference between Eye and Brain Changes with Posture
  • 2016
  • Ingår i: Annals of Neurology. - : Wiley. - 0364-5134 .- 1531-8249. ; 80:2, s. 269-276
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The discovery of a posture-dependent effect on the difference between intraocular pressure (IOP) and intracranial pressure (ICP) at the level of lamina cribrosa could have important implications for understanding glaucoma and idiopathic intracranial hypertension and could help explain visual impairments in astronauts exposed to microgravity. The aim of this study was to determine the postural influence on the difference between simultaneously measured ICP and IOP.Methods: Eleven healthy adult volunteers (age = 46 ± 10 years) were investigated with simultaneous ICP, assessed through lumbar puncture, and IOP measurements when supine, sitting, and in 9° head-down tilt (HDT). The trans–lamina cribrosa pressure difference (TLCPD) was calculated as the difference between the IOP and ICP. To estimate the pressures at the lamina cribrosa, geometrical distances were estimated from magnetic resonance imaging and used to adjust for hydrostatic effects.Results: The TLCPD (in millimeters of mercury) between IOP and ICP was 12.3 ± 2.2 for supine, 19.8 ± 4.6 for sitting, and 6.6 ± 2.5 for HDT. The expected 24-hour average TLCPD on earth—assuming 8 hours supine and 16 hours upright—was estimated to be 17.3mmHg. By removing the hydrostatic effects on pressure, a corresponding 24-hour average TLCPD in microgravity environment was simulated to be 6.7mmHg.Interpretation: We provide a possible physiological explanation for how microgravity can cause symptoms similar to those seen in patients with elevated ICP. The observed posture dependency of TLCPD also implies that assessment of the difference between IOP and ICP in upright position may offer new understanding of the pathophysiology of idiopathic intracranial hypertension and glaucoma. 
  •  
10.
  • Holmlund, Petter, et al. (författare)
  • Human jugular vein collapse in the upright posture : implications for postural intracranial pressure regulation
  • 2017
  • Ingår i: Fluids and Barriers of the CNS. - : BioMed Central. - 2045-8118. ; 14
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Intracranial pressure (ICP) is directly related to cranial dural venous pressure (P-dural). In the upright posture, P-dural is affected by the collapse of the internal jugular veins (IJVs) but this regulation of the venous pressure has not been fully understood. A potential biomechanical description of this regulation involves a transmission of surrounding atmospheric pressure to the internal venous pressure of the collapsed IJVs. This can be accomplished if hydrostatic effects are cancelled by the viscous losses in these collapsed veins, resulting in specific IJV cross-sectional areas that can be predicted from flow velocity and vessel inclination. Methods: We evaluated this potential mechanism in vivo by comparing predicted area to measured IJV area in healthy subjects. Seventeen healthy volunteers (age 45 +/- 9 years) were examined using ultrasound to assess IJV area and flow velocity. Ultrasound measurements were performed in supine and sitting positions. Results: IJV area was 94.5 mm(2) in supine and decreased to 6.5 +/- 5.1 mm(2) in sitting position, which agreed with the predicted IJV area of 8.7 +/- 5.2 mm(2) (equivalence limit +/- 5 mm(2), one-sided t tests, p = 0.03, 33 IJVs). Conclusions: The agreement between predicted and measured IJV area in sitting supports the occurrence of a hydrostatic-viscous pressure balance in the IJVs, which would result in a constant pressure segment in these collapsed veins, corresponding to a zero transmural pressure. This balance could thus serve as the mechanism by which collapse of the IJVs regulates P-dural and consequently ICP in the upright posture.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 27

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy