SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wennerberg Ann 1955 ) ;lar1:(gu);pers:(Galli Silvia)"

Sökning: WFRF:(Wennerberg Ann 1955 ) > Göteborgs universitet > Galli Silvia

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alenezi, Ali, et al. (författare)
  • Osseointegration effects of local release of strontium ranelate from implant surfaces in rats
  • 2019
  • Ingår i: Journal of Materials Science: Materials in Medicine. - : Springer Science and Business Media LLC. - 0957-4530 .- 1573-4838. ; 30:10, s. 116-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND : Numerous studies have reported the beneficial effects of strontium on bone growth, particularly by stimulating osteoblast proliferation and differentiation. Thus, strontium release around implants has been suggested as one possible strategy to enhance implant osseointegration. AIM : This study aimed to evaluate whether the local release of strontium ranelate (Sr-ranelate) from implants coated with mesoporous titania could improve bone formation around implants in an animal model. MATERIALS AND METHODS : Mesoporous titania (MT) thin coatings were formed utilizing the evaporation induced self-assembly (EISA) method using Pluronic (P123) with or without the addition of poly propylene glycol (PPG) to create materials with two different pore sizes. The MT was deposited on disks and mini-screws, both made of cp Ti grade IV. Scanning electron microscopy (SEM) was performed to characterize the MT using a Leo Ultra55 FEG instrument (Zeiss, Oberkochen, Germany). The MT was loaded with Sr-ranelate using soaking and the drug uptake and release kinetics to and from the surfaces were evaluated using quartz crystal microbalance with dissipation monitoring (QCM-D) utilizing a Q-sense E4 instrument. For the in vivo experiment, 24 adult rats were analyzed at two time points of implant healing (2 and 6 weeks). Titanium implants shaped as mini screws were coated with MT films and divided into two groups; supplied with Sr-ranelate (test group) and without Sr-ranelate (control group). Four implants (both test and control) were inserted in the tibia of each rat. The in vivo study was evaluated using histomorphometric analyses of the implant/bone interphase using optical microscopy. RESULTS : SEM images showed the successful formation of evenly distributed MT films covering the entire surface with pore sizes of 6 and 7.2 nm, respectively. The QCM-D analysis revealed an absorption of 3300 ng/cm2 of Sr-ranelate on the 7.2 nm MT, which was about 3 times more than the observed amount on the 6 nm MT (1200 ng/cm2). Both groups showed sustained release of Sr-ranelate from MT coated disks. The histomorphometric analysis revealed no significant differences in bone implant contact (BIC) and bone area (BA) between the implants with Sr-ranelate and implants in the control groups after 2 and 6 weeks of healing (BIC with a p-value of 0.43 after 2 weeks and 0.172 after 6 weeks; BA with a p-value of 0.503 after 2 weeks, and 0.088 after 6 weeks). The mean BIC and BA values within the same group showed significant increase among all groups between 2 and 6 weeks. CONCLUSION : This study could not confirm any positive effects of Sr-ranelate on implant osseointegration.
  •  
2.
  • Bruns, S., et al. (författare)
  • On the material dependency of peri-implant morphology and stability in healing bone
  • 2023
  • Ingår i: Bioactive Materials. - : Elsevier. - 2452-199X. ; 28, s. 155-166
  • Tidskriftsartikel (refereegranskat)abstract
    • The microstructural architecture of remodeled bone in the peri-implant region of screw implants plays a vital role in the distribution of strain energy and implant stability. We present a study in which screw implants made from titanium, polyetheretherketone and biodegradable magnesium-gadolinium alloys were implanted into rat tibia and subjected to a push-out test four, eight and twelve weeks after implantation. Screws were 4 mm in length and with an M2 thread. The loading experiment was accompanied by simultaneous three-dimensional imaging using synchrotron-radiation microcomputed tomography at 5 mu m resolution. Bone deformation and strains were tracked by applying optical flow-based digital volume correlation to the recorded image sequences. Implant stabilities measured for screws of biodegradable alloys were comparable to pins whereas non-degradable biomaterials experienced additional mechanical stabilization. Peri-implant bone morphology and strain transfer from the loaded implant site depended heavily on the biomaterial utilized. Titanium implants stimulated rapid callus formation displaying a consistent monomodal strain profile whereas the bone volume fraction in the vicinity of magnesium-gadolinium alloys exhibited a minimum close to the interface of the implant and less ordered strain transfer. Correlations in our data suggest that implant stability benefits from disparate bone morphological properties depending on the biomaterial utilized. This leaves the choice of biomaterial as situational depending on local tissue properties.
  •  
3.
  • Kruger, D., et al. (författare)
  • High-resolution ex vivo analysis of the degradation and osseointegration of Mg-xGd implant screws in 3D
  • 2022
  • Ingår i: Bioactive Materials. - : Elsevier BV. - 2452-199X. ; 13, s. 37-52
  • Tidskriftsartikel (refereegranskat)abstract
    • Biodegradable magnesium (Mg) alloys can revolutionize osteosynthesis, because they have mechanical properties similar to those of the bone, and degrade over time, avoiding the need of removal surgery. However, they are not yet routinely applied because their degradation behavior is not fully understood. In this study we have investigated and quantified the degradation and osseointegration behavior of two biodegradable Mg alloys based on gadolinium (Gd) at high resolution. Mg-5Gd and Mg-10Gd screws were inserted in rat tibia for 4, 8 and 12 weeks. Afterward, the degradation rate and degradation homogeneity, as well as bone-to-implant interface, were studied with synchrotron radiation micro computed tomography and histology. Titanium (Ti) and polyether ether ketone (PEEK) were used as controls material to evaluate osseointegration. Our results showed that Mg-5Gd degraded faster and less homogeneously than Mg-10Gd. Both alloys gradually form a stable degradation layer at the interface and were surrounded by new bone tissue. The results were correlated to in vitro data obtained from the same material and shape. The average bone-to-implant contact of the Mg-xGd implants was comparable to that of Ti and higher than for PEEK. The results suggest that both Mg-xGd alloys are suitable as materials for bone implants.
  •  
4.
  • Peruzzi, Niccolò, et al. (författare)
  • Multimodal ex vivo methods reveal that Gd-rich corrosion byproducts remain at the implant site of biodegradable Mg-Gd screws
  • 2021
  • Ingår i: Acta Biomaterialia. - : Elsevier. - 1742-7061 .- 1878-7568. ; 136, s. 582-591
  • Tidskriftsartikel (refereegranskat)abstract
    • Extensive research is being conducted on magnesium (Mg) alloys for bone implant manufacturing, due to their biocompatibility, biodegradability and mechanical properties. Gadolinium (Gd) is among the most promising alloying elements for property control in Mg alloy implants; however, its toxicity is controversial. Investigating Gd behavior during implant corrosion is thus of utmost importance. In this study, we analyzed the degradation byproducts at the implant site of biodegradable Mg-5Gd and Mg-10Gd implants after 12 weeks healing time, using a combination of different imaging techniques: histology, energy-dispersive x-ray spectroscopy (EDX), x-ray microcomputed tomography (µCT) and neutron µCT. The main finding has been that, at the healing time in exam, the corrosion appears to have involved only the Mg component, which has been substituted by calcium and phosphorus, while the Gd remains localized at the implant site. This was observed in 2D by means of EDX maps and extended to 3D with a novel application of neutron tomography. X-ray fluorescence analysis of the main excretory organs also did not reveal any measurable accumulation of Gd, further reinforcing the conclusion that very limited or no removal at all of Gd-alloy happened during degradation.
  •  
5.
  • Reinedahl, David, et al. (författare)
  • Aseptic Ligatures Induce Marginal Peri-Implant Bone Loss-An 8-Week Trial in Rabbits
  • 2019
  • Ingår i: Journal of Clinical Medicine. - : MDPI. - 2077-0383. ; 8:8
  • Tidskriftsartikel (refereegranskat)abstract
    • The clinical value of ligature-induced experimental peri-implantitis studies has been questioned due to the artificial nature of the model. Despite repeated claims that ligatures of silk, cotton and other materials may not induce bone resorption by themselves; a recent review showed that the tissue reaction toward them has not been investigated. Hence, the current study aimed to explore the hard and soft tissue reactions toward commonly used ligature materials. A total of 60 dental implants were inserted into the femur ( = 20) and tibia ( = 40) of 10 rabbits. The femoral implants were ligated with sterile 3-0 braided silk in one leg and sterile cotton retraction chord in the other leg. The tibial implants were ligated with silk or left as non-ligated controls. All wounds were closed in layers. After a healing time of 8 weeks, femoral (silk versus cotton) and proximal tibial (silk versus non-ligated control) implants were investigated histologically. Distal tibial (silk versus non-ligated control) implants were investigated with real time polymerase chain reaction (qPCR). The distance from the implant-top to first bone contact point was longer for silk ligated implants compared to non-ligated controls ( = 0.007), but did not vary between cotton and silk. The ligatures triggered an immunological reaction with cell infiltrates in close contact with the ligature materials, adjacent soft tissue encapsulation and bone resorption. qPCR further demonstrated an upregulated immune response toward the silk ligatures compared to non-ligated controls. Silk and cotton ligatures provoke foreign body reactions of soft tissue encapsulation type and bone resorption around implants in the absence of plaque.
  •  
6.
  • Reinedahl, David, et al. (författare)
  • Review of PEEK implants and biomechanical and immunological responses to a zirconium phosphate nano-coated PEEK, a blasted PEEK, and a turned titanium implant surface
  • 2022
  • Ingår i: American journal of dentistry. - : Mosher & Linder, Inc.. - 0894-8275. ; 35:2, s. 152-160
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To investigate the biomechanical and immunological reactions to coated and non-coated blasted PEEK implants in vivo after 12 weeks and review the associated literature. METHODS: Two osteotomy sites were performed in each proximal tibia of 10 lop-eared rabbits (n= 4 per rabbit). Each rabbit received a randomly placed (1) blasted zirconium phosphate nano-coated PEEK- (nano-ZrP), (2) blasted PEEK- (PEEK) and (3) titanium implant (Ti) and an empty sham site. At 12 weeks, removal torque of all implants and biological investigation with qPCR was performed. The implant surfaces were analyzed prior to insertion with interferometry, SEM and XPS. RESULTS: The interferometry analysis showed that there was no difference in roughness for the uncoated PEEK compared to the ZrP coated PEEK implants. The titanium implants were considerably smoother (Sa= 0.23 µm) than the uncoated Sa= 1.11 µm) and ZrP coated PEEK implants (Sa= 1.12 µm). SEM analysis on the PEEK implants corroborated the interferometry results; no difference in structure between the uncoated vs. the ZrP coated PEEK was visible on the micrometer level. At higher magnifications, the ZrP coating was visible in the SEM as a thin, porous network. All tested implants displayed osseointegration with the highest RTQ for nano-ZrP (18.4 Ncm) followed by PEEK (14.5 Ncm) and Ti (11.5 Ncm). All implants activated the immune system, with elevated macrophage and M2 macrophage qPCR markers at 12 weeks compared to the sham site. CLINICAL SIGNIFICANCE: Nano-ZrP coating improves osseointegration of blasted PEEK implants at 12 weeks of follow-up. Osseointegration of titanium, PEEK and nano-ZrP PEEK is not a normal bone healing process, but rather a shield-off mechanism that appears to be regulated by the innate immune system. Copyright©American Journal of Dentistry.
  •  
7.
  • Toia, Marco, et al. (författare)
  • Clinical Evidence of OsseoSpeed EV Implants: A Retrospective Study and Characterization of the Newly Introduced System.
  • 2019
  • Ingår i: The International journal of periodontics & restorative dentistry. - : Quintessence Publishing. - 1945-3388 .- 0198-7569. ; 39:6, s. 863-874
  • Tidskriftsartikel (refereegranskat)abstract
    • This retrospective study sought to compare a new implant (Astra Tech OsseoSpeed EV) with its predecessor (Astra Tech OsseoSpeed TX) by scanning electron microscopy and interferometry. Radiographic data from 19 patients who underwent implant restoration with EV (n = 49) with a median follow-up of 16 months were evaluated for mean bone level (MBL) changes from delivery of the definitive prosthesis. EV and TX did not differ in surface roughness, and both systems had a tight seal at the implant-abutment interface. The median MBL change of the EV was -0.02 mm mesiodistally after a median follow-up period of 16 months. Greater maintenance of MBL was found in the screw-retained restorations (n = 17) compared to cemented (0.35 ± 0.33 mm and -0.38 ± 0.76 mm, respectively; P = .03). The data suggest that EV shows minimal levels of bone loss and high implant survival.
  •  
8.
  • Toia, Marco, et al. (författare)
  • The use of implant-level connection in screw-retained fixed partial dentures: A 3-year randomised clinical trial
  • 2022
  • Ingår i: Clinical Oral Implants Research. - : Wiley. - 0905-7161 .- 1600-0501. ; 33:1, s. 78-93
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives This randomised controlled trial compares the 3-year outcomes, that is, marginal bone-level (MBL) changes and clinical parameters, between an abutment-level (AL) and implant-level (IL) connection for implants with an internal conical connection (ICC) supporting a screw-retained fixed partial denture. Material and methods Fifty patients with 119 implants were randomly allocated to either the AL or IL group. Radiographic and clinical examinations were performed after one, two, and 3 years. A linear mixed model was used to evaluate the differences between groups. Results The MBL change was not significantly different between the groups at any point. The MBL was 0.12 +/- 0.31 mm (AL) and 0.23 +/- 0.26 mm (IL) after 1 year; 0.15 +/- 0.34 mm (AL) and 0.17 +/- 0.22 mm (IL) after 2 years; 0.18 +/- 0.39 mm (AL) and 0.15 +/- 0.21 mm (IL) after 3 years. The bleeding on probing was 43.44 +/- 39.24% (AL) and 58.19 +/- 41.20% (IL) after 1 year; 35.78 +/- 39.22% (AL) and 50.43 +/- 41.49% (IL) after 2 years; 51.27 +/- 44.63% (AL) and 49.57 +/- 37.31% (IL) after 3 years and was significantly different (p = .025) between 1 and 2 years. The probing depth showed a significant difference at each time point while the plaque was not significant between the groups. The overall technical, biological and prosthetic complication rates were 5.04%, 3.36%, and 16.00%, respectively. Conclusions The MBL change was similar in the groups. The slight differences in the soft tissue complications between the groups are likely not of clinical relevance. An IL connection is considered to be a valid alternative to an AL set-up in ICC implants.
  •  
9.
  • Trindade, Ricardo, et al. (författare)
  • Bone Immune Response to Materials, Part II:Copper and Polyetheretherketone (PEEK) Compared to Titanium at 10 and 28 Days in Rabbit Tibia
  • 2019
  • Ingår i: Journal of Clinical Medicine. - : MDPI AG. - 2077-0383. ; 8:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Osseointegration is likely the result of an immunologically driven bone reaction to materials such as titanium. Osseointegration has resulted in the clinical possibility to anchor oral implants in jaw bone tissue. However, the mechanisms behind bony anchorage are not fully understood and complications over a longer period of time have been reported. The current study aims at exploring possible differences between copper (Cu) and polyetheretherketone (PEEK) materials that do not osseointegrate, with osseointegrating cp titanium as control. The implants were placed in rabbit tibia and selected immune markers were evaluated at 10 and 28 days of follow-up. Cu and PEEK demonstrated at both time points a higher immune activation than cp titanium. Cu demonstrated distance osteogenesis due to a maintained proinflammatory environment over time, and PEEK failed to osseointegrate due to an immunologically defined preferential adipose tissue formation on its surface. The here presented results suggest the description of two different mechanisms for failed osseointegration, both of which are correlated to the immune system.
  •  
10.
  • Trindade, Ricardo, et al. (författare)
  • Osseointegration and foreign body reaction: Titanium implants activate the immune system and suppress bone resorption during the first 4 weeks after implantation
  • 2018
  • Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley. - 1523-0899 .- 1708-8208. ; 20:1, s. 82-91
  • Tidskriftsartikel (refereegranskat)abstract
    • © 2017 Wiley Periodicals, Inc. Background: Osseointegration mechanisms are still not entirely understood. Purpose: The present pilot study aims at demonstrating the involvement of the immune system in the process of osseointegration around titanium implants, comparing bone healing in the presence and absence of a titanium implant. Materials and Methods: Fifteen New Zealand White rabbits had one osteotomy performed at each of the distal femurs; on one side, no implant was placed (sham) and on the other side a titanium implant was introduced. Subjects were sacrificed at 10 and 28 days for gene expression analysis (three subjects each time point) and for decalcified qualitative histology (six subjects each time point). At 10 days, the three subjects for gene expression analysis were part of the six subjects for histology. Results: Gene expression analysis: at 10 days, ARG1 was significantly up-regulated around titanium, indicating an activation of M2-macrophages. At 28 days CD11b, ARG1, NCF-1, and C5aR1 were significantly up-regulated, indicating activation of the innate immune system, respectively M1-macrophages, M2-macrophages and group 2-innate lymphoid cells, neutrophils, and the complement system; on the other hand, the bone resorption markers RANKL, OPG, cathepsin K, and TRAP were significantly down-regulated around titanium. Histology: at 10 days new bone formation is seen around both sham and titanium sites, separating bone marrow from the osteotomy/implant site; at 28 days no bone trabeculae is seen on the sham site, which is healing at the original cortical level, whereas around titanium implants, bone continues into organization of more mature cortical-like bone, forming a layer between the implant and the bone marrow. Conclusions: The presence of a titanium implant during bone healing activates the immune system and displays type 2 inflammation, which is likely to guide the host-biomaterial relationship. At the same time, bone resorption is suppressed around titanium sites compared to sham sites after 4 weeks of implantation, suggesting a shift to a more pronounced bone forming environment. This suggests two important steps in osseointegration: identification of the titanium foreign body by the immune system and the development of a bone forming environment, that at tissue level translates into bone build-up on the titanium surface and can be perceived as an attempt to isolate the foreign body from the bone marrow space.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy