SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wennerberg Ann 1955 ) ;pers:(Östman Pär Olov 1968)"

Sökning: WFRF:(Wennerberg Ann 1955 ) > Östman Pär Olov 1968

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Östman, Pär-Olov, 1968, et al. (författare)
  • Immediate occlusal loading of NanoTite PREVAIL implants: a prospective 1-year clinical and radiographic study.
  • 2010
  • Ingår i: Clinical implant dentistry and related research. - : Wiley. - 1708-8208 .- 1523-0899. ; 12:1, s. 39-47
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Recently, a new implant surface texture, featuring application of nanometer-scale calcium phosphate has been shown to enhance early bone fixation and formation in preclinical studies and in human histomorphometric studies, which may be beneficial in immediate loading situations. AIM: The purpose of the present prospective clinical study was to, during 1 year, clinically and radiographically evaluate a nanometer scale surface modified implant placed for immediate loading of fixed prostheses in both maxillary and mandibular regions. MATERIALS AND METHODS: Thirty-five out of 38 patients who needed implant treatment and met inclusion criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 25 Ncm prior to final seating and an implant stability quotient above 55. A total of 102 NanoTite PREVAIL (NTP) implants (BIOMET 3i, Palm Beach Gardens, FL, USA) (66 maxillary and 36 mandibular) were placed by one investigator, and the majority of these were placed in posterior regions (65%) and in soft bone (69%). A total of 44 prosthetic constructions were evaluated consisting of 14 single-tooth restorations, 26 fixed partial dentures, and four complete fixed restorations. All provisional constructions were delivered within 1 hour, and the final constructions placed after 4 months. Implants were monitored for clinical and radiographic outcomes at follow-up examinations scheduled for 3, 6, and 12 months. RESULTS: Of the 102 study implants, one implant failed. The simple cumulative survival rate value at 1 year was 99.2%. The average marginal bone resorption was 0.37 mm (SD 0.39) during the first year in function. According to the success criteria of Albrektsson and Zarb, success grade 1 was found with 93% of the implants. CONCLUSION: Although limited to the short follow-up, immediate loading of NanoTite Prevail implants seems to be a viable option in implant rehabilitation, at least when a good initial fixation is achieved.
  •  
2.
  • Östman, Pär-Olov, 1968, et al. (författare)
  • Immediate Occlusal Loading of NanoTite™ Tapered Implants: A Prospective 1-Year Clinical and Radiographic Study.
  • 2013
  • Ingår i: Clinical implant dentistry and related research. - : Wiley. - 1708-8208 .- 1523-0899. ; 15:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: During the last decade, high success rates have been reported for implants placed with immediate loading procedures, especially when bone quality and quantity provide good implant stability. In many of these studies, straight-walled implants with moderately rough surfaces were employed. Tapered implants are becoming increasingly more popular due to standardized drilling protocols and reports of high initial primary stability. Purpose: The aim of the present prospective, single center clinical study was to evaluate surface topographical analysis and the clinical and radiographic outcomes of the NanoTite™ (BIOMET 3i, Palm Beach Gardens, FL, USA) Tapered Implant when used for immediate loading of fixed prostheses and single-tooth restorations. Materials and Methods: Forty-two patients who needed implant treatment and met admission criteria agreed to participate in the study and were consecutively enrolled. Surgical implant placement requirements consisted of a final torque of a least 30 Ncm prior to final seating and an implant stability quotient above 55. A total of 139 NanoTite Tapered implants (112 maxillary and 27 mandibular) were placed by one investigator, and the majority of these implants (n = 77/55%) were placed in posterior regions, and in soft bone (n = 90/65%). A total of 57 prosthetic constructions were evaluated consisting of 20 single-tooth restorations, 30 fixed partial dentures, and 7 complete, fixed maxillary restorations. Radiographs were taken at baseline and at 12 months of follow-up. Results: Of the 139 study implants, one implant failure was declared. The overall cumulative survival rate at 1 year is 99.4%. Mean marginal bone resorption is 1.01 mm (SD 0.85) during the first year of function. Conclusion: Although limited to the short follow-up, immediate loading of NanoTite Tapered implants seems to be a viable option in implant rehabilitation, when insertion torque of at least 30 Ncm is achieved. Further studies are needed to authenticate the finding of this study.
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3
Typ av publikation
tidskriftsartikel (3)
Typ av innehåll
refereegranskat (3)
Författare/redaktör
Wennerberg, Ann, 195 ... (3)
Albrektsson, Tomas, ... (2)
Sennerby, Lars, 1960 (1)
Ekestubbe, Annika, 1 ... (1)
Hellman, Mats (1)
Lärosäte
Göteborgs universitet (3)
Malmö universitet (3)
Språk
Engelska (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy