SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(White Ian) ;pers:(Goossens An)"

Search: WFRF:(White Ian) > Goossens An

  • Result 1-10 of 13
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Thyssen, Jacob Pontoppidan, et al. (author)
  • p-Phenylenediamine sensitization is more prevalent in central and southern European patch test centres than in Scandinavian: results from a multicentre study
  • 2009
  • In: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 60:6, s. 314-319
  • Journal article (peer-reviewed)abstract
    • Positive patch test reactions to p-phenylenediamine (PPD) are common. PPD is used in oxidative hair dyes and is also present in dark henna temporary 'tattoos'. Cross-sensitization to other contact allergens may occur. Because subjects sensitized to PPD are at risk of clinically severe reactions upon hair dyeing, there is a need for 'current' prevalence data on PPD sensitization. To compare PPD patch test results from dermatitis patients tested between 2003 and 2007 in 10 European patch test centres and to analyse the causes and determine relevance of positive PPD patch test reactions. Patch testing was performed using PPD (1% free base in petrolatum from Trolab (Almirall Hermal GmbH, Reinbeck, Germany) or Chemotechnique (Malmo, Sweden), equivalent to 0.090 mg/cm(2) in the TRUE (R) test from MEKOS Laboratories AS). Statistical analysis was performed using the chi-squared test. The weighted average prevalence was 4.6% among 21 515 patients. PPD sensitization occurred more often in centres located in Central and Southern Europe than in Scandinavian centres (odds ratio = 2.40; 95% confidence interval = 2.07-2.78). The overall proportion of positive patch test reactions to PPD that were registered as being of either current or 'past' relevance was high (weighted average 53.6% and 20.3%, respectively). Consumer hair dyeing was the most prominent cause of PPD sensitization (weighted average 41.8%). Furthermore, occupational hair dye exposure (10.6%) and cross-sensitization to textile dyes (12.6%) were frequently reported. PPD sensitization caused by exposure to hair dyes is frequent and remains a present problem for patients visiting contact dermatitis clinics, especially in patch test centres located in Central and Southern Europe.
  •  
2.
  • Agner, Tove, et al. (author)
  • Contact sensitisation in hand eczema patients-relation to subdiagnosis, severity and quality of life: a multi-centre study
  • 2009
  • In: Contact Dermatitis. - 0105-1873. ; 61:5, s. 291-296
  • Journal article (peer-reviewed)abstract
    • Background Contact sensitisation has been identified as a factor associated with poor prognosis for patients with hand eczema. Objectives To study implications of contact sensitisation with respect to severity, quality of life (QoL) and subdiagnosis of hand eczema. Methods The study was performed as a multi-centre, cross-sectional study from 10 European clinics. All patients were patch tested, and severity of hand eczema assessed by Hand Eczema Severity Index. A multi-variate analysis was performed to explore which factors influenced severity, QoL and sick leave. Results A total 416 patients were included, and 63% had contact sensitisation to one or more of the tested allergens. More women (66%) than men (51%) were sensitized. No significant association was found between sensitisation to specific allergens, disease severity, QoL or diagnostic subgroups. High age, male sex, atopic eczema and presence of contact sensitisation were independent risk factors for increased severity as measured by Hand Eczema Severity Index. Furthermore, the severity of hand eczema increased by the number of contact sensitisations detected (P = 0.023). High age and personal history of atopic eczema were independent risk factors for low QoL, as measured by Dermatology Life Quality Index, and atopic eczema as well as allergic contact dermatitis as subdiagnosis was associated with increased sick leave. Conclusion Diagnostic subgroups were not found to be related to specific allergens. Contact sensitisation was found to be a risk factor for increased severity of hand eczema, as did high age, male sex and atopic eczema.
  •  
3.
  • Agner, Tove, et al. (author)
  • Hand eczema severity and quality of life: a cross-sectional, multicentre study of hand eczema patients
  • 2008
  • In: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 59:1, s. 43-47
  • Journal article (peer-reviewed)abstract
    • Background and Objectives: Hand eczema is a chronic disease with negative impact on quality of life (QoL). In this study, QoL in hand eczema patients is assessed and related to age, sex, severity, and diagnostic subgroups. Methods: A total of 416 patients with hand eczema from 10 European patch test clinics participated in the study. Data on QoL were obtained from a self-administered questionnaire using the Dermatology Life Quality Index (DLQI). Severity was assessed by a scoring system (Hand Eczema Severity Index, HECSI) as well as frequency of eruptions and sick leave due to hand eczema. Results: No significant difference was found between males and females with respect to QoL [DLQI median values and 25/75 percentiles for males and females being 7.0 (3-14) and 8.0 (3-13), respectively], although males were more severely affected than females (P < 0.025). A significant positive correlation was found for hand eczema severity and age (P < 0.001), while no significant correlation was found for QoL and age. QoL was found increasingly reduced when sick leave was getting higher (P < 0.001). A statistically significant correlation between QoL (as measured by DLQI) and hand eczema severity as measured by HECSI was found (P < 0.001). No significant difference in QoL was found between diagnostic subgroups. Conclusions: QoL was found markedly negatively affected in hand eczema patients and was significantly correlated to disease severity. No significant difference in QoL was found between males and females, in spite of significantly more severe eczema in males, indicating that QoL in female patients is more easily affected.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  • Johansen, Jeanne D., et al. (author)
  • European Society of Contact Dermatitis guideline for diagnostic patch testing : recommendations on best practice
  • 2015
  • In: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 73:4, s. 195-221
  • Research review (peer-reviewed)abstract
    • The present guideline summarizes all aspects of patch testing for the diagnosis of contact allergy in patients suspected of suffering, or having been suffering, from allergic contact dermatitis or other delayed-type hypersensitivity skin and mucosal conditions. Sections with brief descriptions and discussions of different pertinent topics are followed by a highlighted short practical recommendation. Topics comprise, after an introduction with important definitions, materials, technique, modifications of epicutaneous testing, individual factors influencing the patch test outcome or necessitating special considerations, children, patients with occupational contact dermatitis and drug eruptions as special groups, patch testing of materials brought in by the patient, adverse effects of patch testing, and the final evaluation and patient counselling based on this judgement. Finally, short reference is made to aspects of (continuing) medical education and to electronic collection of data for epidemiological surveillance.
  •  
8.
  • Matura, Mihaly, 1964, et al. (author)
  • Not only oxidized R-(+)- but also S-(-)-limonene is a common cause of contact allergy in dermatitis patients in Europe.
  • 2006
  • In: Contact dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 55:5, s. 274-9
  • Journal article (peer-reviewed)abstract
    • Limonene, one of the most often used fragrance terpenes in any kind of scented products, is prone to air-oxidation. The oxidation products formed have a considerable sensitizing potential. In previous patch test studies on consecutively tested dermatitis patients, oxidized R-limonene has been proven to be a good and frequent indicator of fragrance-related contact allergy. The current study extends these investigations to 6 European clinics of dermatology, where the oxidation mixture of both enantiomers of limonene (R and S) have been tested in 2411 dermatitis patients. Altogether, 63 out of 2411 patients tested (2.6%) reacted to 1 or both the oxidized limonene preparations. Only 2.3% reacted to the oxidized R-limonene and 2.0% to the oxidized S-limonene. In 57% of the cases, simultaneous reactions were observed to both oxidation mixtures. Concomitant reactions to the fragrance mix, colophonium, Myroxylon pereirae, and fragrance-related contact allergy were common in patients reacting to 1 or both the oxidized limonene enantiomers. Our study provides clinical evidence for the importance of oxidation products of limonene in contact allergy. It seems advisable to screen consecutive dermatitis patients with oxidized limonene 3% petrolatum, although this patch test material is not yet commercially available.
  •  
9.
  •  
10.
  • Pontén, Ann, et al. (author)
  • Patch testing with 2.0% (0.60 mg/cm(2) ) formaldehyde instead of 1.0% (0.30 mg/cm(2) ) detects significantly more contact allergy.
  • 2013
  • In: Contact Dermatitis. - : Wiley. - 0105-1873. ; 68:1, s. 50-53
  • Journal article (peer-reviewed)abstract
    • Background.The currently used patch test concentration for formaldehyde is 1.0% (wt/vol) in water. However, clinical experience and previous studies suggest that 1.0% might be insufficient for detecting an optimized number of clinically relevant cases of contact allergy to formaldehyde. Objectives.To validate earlier patch test results for comparison of 1% (wt/vol) and 2% (wt/vol) formaldehyde in water, and to investigate co-reactivity with quaternium-15. Materials and methods.In 12 dermatology clinics, 3591 patients were routinely patch tested simultaneously with 2.0% (wt/vol) (0.60 mg/cm(2) ) and 1.0% (wt/vol) (0.30 mg/cm(2) ) formaldehyde. Micropipettes were used for delivering the exact dosage of the allergen. Results.Significantly more patients reacted to 2.0% formaldehyde than to 1.0% (3.4% versus 1.8%, p < 0.001). Overall, there were no sex differences between those reacting positively to 2.0% and 1.0%. Of 25 quaternium-15-positive patients, 4 (0.1%) reacted positively without reacting to formaldehyde. Conclusion.On the basis of the results of this multicentre study, as well as of previous studies, it can be suggested that 2.0% (wt/vol) in water formaldehyde should be used in routine patch testing in the baseline series.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view