SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wieland Thomas) ;mspu:(conferencepaper)"

Sökning: WFRF:(Wieland Thomas) > Konferensbidrag

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Reifarth, R., et al. (författare)
  • Nuclear astrophysics with radioactive ions at FAIR
  • 2016
  • Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 665:1
  • Konferensbidrag (refereegranskat)abstract
    • The nucleosynthesis of elements beyond iron is dominated by neutron captures in the s and r processes. However, 32 stable, proton-rich isotopes cannot be formed during those processes, because they are shielded from the s-process flow and r-process beta-decay chains. These nuclei are attributed to the p and rp process. For all those processes, current research in nuclear astrophysics addresses the need for more precise reaction data involving radioactive isotopes. Depending on the particular reaction, direct or inverse kinematics, forward or time-reversed direction are investigated to determine or at least to constrain the desired reaction cross sections. The Facility for Antiproton and Ion Research (FAIR) will offer unique, unprecedented opportunities to investigate many of the important reactions. The high yield of radioactive isotopes, even far away from the valley of stability, allows the investigation of isotopes involved in processes as exotic as the r or rp processes.
  •  
2.
  • Lieder, R M, et al. (författare)
  • Gamma-ray tracking arrays
  • 2001
  • Ingår i: PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, VOL 46. ; , s. 399-407
  • Konferensbidrag (refereegranskat)abstract
    • The next generation of 4 pi arrays for high-precision gamma -ray spectroscopy will involve "gamma -ray tracking front-end on digital signal processing techniques, which allows to extract energy, timing and spatial information on the interactions of a gamma -ray in the Ge detector by pulse shape analysis of its signals. Utilizing the information on the positions of the interaction points and the energies released at each point the tracks of the gamma -rays in a Ge shell can be reconstructed in three dimensions.
  •  
3.
  • Moosmann, Julian, et al. (författare)
  • A load frame for in situ tomography at PETRA III
  • 2019
  • Ingår i: Developments in X-Ray Tomography XII. - : SPIE. - 0277-786X .- 1996-756X. - 9781510629196 ; 11113
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • A load frame for in situ mechanical testing is developed for the microtomography end stations at the imaging beamline P05 and the high-energy material science beamline P07 of PETRA III at DESY, both operated by the Helmholtz- Zentrum Geesthacht. The load frame is fully integrated into the beamline control system and can be controlled via a feedback loop. All relevant parameters (load, displacement, temperature, etc.) are continuously logged. It can be operated in compression or tensile mode applying forces of up to 1 kN and is compatible with all contrast modalities available at IBL and HEMS i.e. conventional attenuation contrast, propagation based phase contrast and differential phase contrast using a grating interferometer. The modularity and flexibility of the load frame allows conducting a wide range of experiments. E.g. compression tests to understand the failure mechanisms in biodegradable implants in rat bone or to investigate the mechanics and kinematics of the tessellated cartilage skeleton of sharks and rays, or tensile tests to illuminate the structure-property relationship in poplar tension wood or to visualize the 3D deformation of the tendonbone insertion. We present recent results from the experiments described including machine-learning driven volume segmentation and digital volume correlation of load tomography sequences.
  •  
4.
  • Moosmann, Julian, et al. (författare)
  • Biodegradable magnesium-based implants in bone studied by synchrotron radiation microtomography
  • 2017
  • Ingår i: Developments in X-Ray Tomography XI. - : SPIE - International Society for Optical Engineering. ; 10391
  • Konferensbidrag (refereegranskat)abstract
    • Permanent implants made of titanium or its alloys are the gold standard in many orthopedic and traumatological applications due to their good biocompatibility and mechanical properties. However, a second surgical intervention is required for this kind of implants as they have to be removed in the case of children that are still growing or on patient's demand. Therefore, magnesium-based implants are considered for medical applications as they are degraded under physiological conditions. The major challenge is tailoring the degradation in a manner that is suitable for a biological environment and such that stabilization of the bone is provided for a controlled period. In order to understand failure mechanisms of magnesium-based implants in orthopedic applications and, further, to better understand the osseointegration, screw implants in bone are studied under mechanical load by means of a push-out device installed at the imaging beamline P05 of PETRA III at DESY. Conventional absorption contrast microtomography and phasecontrast techniques are applied in order to monitor the bone-to-implant interface under increasing load conditions. In this proof-of-concept study, first results from an in situ push-out experiment are presented.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy