SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wollmer Per) ;hsvcat:1"

Sökning: WFRF:(Wollmer Per) > Naturvetenskap

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Rissler, Jenny, et al. (författare)
  • An experimental study on lung deposition of inhaled 2 μm particles in relation to lung characteristics and deposition models
  • 2023
  • Ingår i: Particle and Fibre Toxicology. - : BioMed Central Ltd. - 1743-8977. ; 20
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The understanding of inhaled particle respiratory tract deposition is a key link to understand the health effects of particles or the efficiency for medical drug delivery via the lung. However, there are few experimental data on particle respiratory tract deposition, and the existing data deviates considerably when comparing results for particles > 1 μm. Methods: We designed an experimental set-up to measure deposition in the respiratory tract for particles > 1 μm, more specifically 2.3 μm, with careful consideration to minimise foreseen errors. We measured the deposition in seventeen healthy adults (21–68 years). The measurements were performed at tidal breathing, during three consecutive 5-minute periods while logging breathing patterns. Pulmonary function tests were performed, including the new airspace dimension assessment (AiDA) method measuring distal lung airspace radius (r AiDA). The lung characteristics and breathing variables were used in statistical models to investigate to what extent they can explain individual variations in measured deposited particle fraction. The measured particle deposition was compared to values predicted with whole lung models. Model calculations were made for each subject using measured variables as input (e.g., breathing pattern and functional residual capacity). Results: The measured fractional deposition for 2.3 μm particles was 0.60 ± 0.14, which is significantly higher than predicted by any of the models tested, ranging from 0.37 ± 0.08 to 0.53 ± 0.09. The multiple-path particle dosimetry (MPPD) model most closely predicted the measured deposition when using the new PNNL lung model. The individual variability in measured particle deposition was best explained by breathing pattern and distal airspace radius (r AiDA) at half inflation from AiDA. All models underestimated inter-subject variability even though the individual breathing pattern and functional residual capacity for each participant was used in the model. Conclusions: Whole lung models need to be tuned and improved to predict the respiratory tract particle deposition of micron-sized particles, and to capture individual variations – a variation that is known to be higher for aged and diseased lungs. Further, the results support the hypothesis that the AiDA method measures dimensions in the peripheral lung and that r AiDA, as measured by the AiDA, can be used to better understand the individual variation in the dose to healthy and diseased lungs.
  •  
2.
  • Fridolfsson, Jonatan, 1992, et al. (författare)
  • Physical activity spectrum discriminant analysis—A method to compare detailed patterns between groups
  • 2021
  • Ingår i: Scandinavian Journal of Medicine and Science in Sports. - : Wiley. - 0905-7188 .- 1600-0838. ; 31:12, s. 2333-2342
  • Tidskriftsartikel (refereegranskat)abstract
    • Investigating physical activity (PA) patterns as a detailed intensity spectrum instead of crude intensity categories have improved the ability to analyze the relationship between measured PA and health variables. The aim of this methodological study was to introduce and investigate the utility of using detailed PA intensity spectrum compared to crude PA intensity categories for comparison of PA between groups and between repeated measures. The study sample consisted of two groups of children, where one group was scheduled for extended physical education (PE) by daily classes while the other group followed usual PE schedule. Accelerometer data was processed into traditional crude PA intensity categories and into detailed PA intensity spectrum. Multivariate partial least squares regression for discriminant analysis (PLS-DA) was applied for PA intensity spectrum group comparison and compared to traditional univariate statistical analysis. Repeated measures were investigated using independent PLS-DA as well as multilevel PLS-DA for paired analysis. While traditional analysis of crude PA intensity categories was unable to find any group differences, multivariate analysis of the PA intensity spectrum identified statistically significant differences. By the extension of multilevel PLS-DA for paired comparison, a clear difference in the PA intensity spectrum was demonstrated between repeated measures. In conclusion, analysis of detailed PA intensity spectrum demonstrates utility for comparing detailed PA data between groups and between repeated measures in interventional and observational research.
  •  
3.
  • Linell, Julia, et al. (författare)
  • Alterations of particle deposition in the respiratory tract at increasing activity
  • 2023
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The deposited dose of particles in the respiratory tract is an important factor for understanding health effects of aerosol particles. It is a combination of the exposure, volume of inhaled air and particle deposition. At increasing activity the minute ventilation ( volume of breath x number of breaths ) increase . Little is known about if and how this affects the regional particle deposition.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Oddstig, Jenny, et al. (författare)
  • Comparison of conventional and Si-photomultiplier-based PET systems for image quality and diagnostic performance
  • 2019
  • Ingår i: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 19:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: A new generation of positron emission tomography with computed tomography (PET-CT) was recently introduced using silicon (Si) photomultiplier (PM)-based technology. Our aim was to compare the image quality and diagnostic performance of a SiPM-based PET-CT (Discovery MI; GE Healthcare, Milwaukee, WI, USA) with a time-of-flight PET-CT scanner with a conventional PM detector (Gemini TF; Philips Healthcare, Cleveland, OH, USA), including reconstruction algorithms per vendor's recommendations. METHODS: Imaging of the National Electrical Manufacturers Association IEC body phantom and 16 patients was carried out using 1.5 min/bed for the Discovery MI PET-CT and 2 min/bed for the Gemini TF PET-CT. Images were analysed for recovery coefficients for the phantom, signal-to-noise ratio in the liver, standardized uptake values (SUV) in lesions, number of lesions and metabolic TNM classifications in patients. RESULTS: In phantom, the correct (> 90%) activity level was measured for spheres ≥17 mm for Discovery MI, whereas the Gemini TF reached a correct measured activity level for the 37-mm sphere. In patient studies, metabolic TNM classification was worse using images obtained from the Discovery MI compared those obtained from the Gemini TF in 4 of 15 patients. A trend toward more malignant, inflammatory and unclear lesions was found using images acquired with the Discovery MI compared with the Gemini TF, but this was not statistically significant. Lesion-to-blood-pool SUV ratios were significantly higher in images from the Discovery MI compared with the Gemini TF for lesions smaller than 1 cm (p < 0.001), but this was not the case for larger lesions (p = 0.053). The signal-to-noise ratio in the liver was similar between platforms (p = 0.52). Also, shorter acquisition times were possible using the Discovery MI, with preserved signal-to-noise ratio in the liver. CONCLUSIONS: Image quality was better with Discovery MI compared to conventional Gemini TF. Although no gold standard was available, the results indicate that the new PET-CT generation will provide potentially better diagnostic performance.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy