SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Zhang Hong) ;lar1:(du)"

Sökning: WFRF:(Zhang Hong) > Högskolan Dalarna

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kinyoki, DK, et al. (författare)
  • Mapping local patterns of childhood overweight and wasting in low- and middle-income countries between 2000 and 2017
  • 2020
  • Ingår i: Nature medicine. - : Springer Science and Business Media LLC. - 1546-170X .- 1078-8956. ; 26:5, s. 750-759
  • Tidskriftsartikel (refereegranskat)abstract
    • A double burden of malnutrition occurs when individuals, household members or communities experience both undernutrition and overweight. Here, we show geospatial estimates of overweight and wasting prevalence among children under 5 years of age in 105 low- and middle-income countries (LMICs) from 2000 to 2017 and aggregate these to policy-relevant administrative units. Wasting decreased overall across LMICs between 2000 and 2017, from 8.4% (62.3 (55.1–70.8) million) to 6.4% (58.3 (47.6–70.7) million), but is predicted to remain above the World Health Organization’s Global Nutrition Target of <5% in over half of LMICs by 2025. Prevalence of overweight increased from 5.2% (30 (22.8–38.5) million) in 2000 to 6.0% (55.5 (44.8–67.9) million) children aged under 5 years in 2017. Areas most affected by double burden of malnutrition were located in Indonesia, Thailand, southeastern China, Botswana, Cameroon and central Nigeria. Our estimates provide a new perspective to researchers, policy makers and public health agencies in their efforts to address this global childhood syndemic.
  •  
2.
  • He, Wei, et al. (författare)
  • Operational performance of a novel heat pump assisted solar facade loop-heat-pipe water heating system
  • 2015
  • Ingår i: Applied Energy. - : Elsevier BV. - 0306-2619 .- 1872-9118. ; 146, s. 371-382
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper aims to present an investigation into the operational performance of a novel heat pump assisted solar façade loop-heat-pipe (LHP) water heating system using both theoretical and experimental methods. This involved (1) development of a computer numerical model; (2) simulation of the operational performance of the system by using the model; (3) test rig construction; and (4) dedicated experiment for verification of the model. It was found that the established model is able to predict the operational performance of the system at a reasonable accuracy. Analyses of the research results indicated that under the selected testing conditions, the average thermal efficiency of the LHP module was around 71%, much higher than that of the loop heat pipe without heat pump assistance. The thermal efficiency of the LHP module grew when the heat pump was turned-on and fell when the heat pump was turned-off. The water temperature remained a steadily growing trend throughout the heat pump turned-on period. Neglecting the heat loss of the water tank, the highest coefficient of the performance could reach up to 6.14 and its average value was around 4.93. In overall, the system is a new façade integrated, highly efficient and aesthetically appealing solar water heating configuration; wide deployment of the system will help reduce fossil fuel consumption in the building sector and carbon emission to the environment.
  •  
3.
  • He, Wei, et al. (författare)
  • Theoretical investigation of the thermal performance of a novel solar loop-heat-pipe facade-based heat pump water heating system
  • 2014
  • Ingår i: Energy and Buildings. - : Elsevier BV. - 0378-7788 .- 1872-6178. ; 77, s. 180-191
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the paper was to present a dedicated theoretical investigation into the thermal performance of a novel solar loop-heat-pipe façade based heat pump water heating system. This involved thermo-fluid analyses, computer numerical model development, the model running up, modelling result analyses and conclusion. An energy balance network was established on each part and the whole range of the system to address the associated energy conversion and transfer processes. On basis of this, a computer numerical model was developed and run up to predict the thermal performance of such a system at different system configurations, layouts and operational conditions. It was suggested that the loop heat pipes could be filled with either water, R134a, R22 or R600a; of which R600a is the favourite working fluid owing to its relatively larger heat transfer capacity and positive pressure in operation. Variations in the system configuration, i.e., glazing covers, heat exchangers, would lead to identifiable differences in the thermal performance of the system, represented by the thermal efficiency and COP. Furthermore, impact of the external operational parameters, i.e., solar radiation and ambient air temperature, to the system's thermal performance was also investigated. The research was based on an innovative loop-heat-pipe façade and came up with useful results reflecting the thermal performance of the combined system between the façade and heat pump. This would help promote development and market penetration of such an innovative solar heating technology, and thus contribute to achieving the global targets in energy saving and carbon emission reduction.
  •  
4.
  • Shen, Jingchun, et al. (författare)
  • Experimental study of a compact unglazed Solar Thermal Facade (STF) for energy-efficient buildings
  • 2016
  • Ingår i: Energy Procedia. - : Elsevier BV. - 1876-6102. ; 104, s. 3-8
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents a real-time experimental measurement of a novel compact unglazed solar thermal facade (STF) system at outdoor environment in Shanghai, China for about a whole summer week. It demonstrates the daily average solar thermal efficiency fluctuated from 40% to 45.5%. The overall result indicates the advantages of the STF with simple structure, low cost and high feasibility in architectural design for energy-efficient building application, especially at future district or city levels.
  •  
5.
  • Shen, Jingchun, et al. (författare)
  • Optimizing the configuration of a compact thermal facade module for solar renovation concept in buildings
  • 2016
  • Ingår i: Energy Procedia. - : Elsevier BV. - 1876-6102. ; 104, s. 9-14
  • Tidskriftsartikel (refereegranskat)abstract
    • Solar concepts show potentially an improved cost-performance (energy) ratio when applied as the integrated parts of building renovations. This paper reported a compact solar thermal facade (STF) module with the internally extruded flow channel suiting for solar renovation concept in buildings. A few of impact factors were considered for the parametric study in order to optimize the STF's configuration for various applications through the validated simulation model. The overall research results are expected to be useful for further improvement in the thermal performance of solar renovation measures.
  •  
6.
  • Zhang, Xingxing, et al. (författare)
  • Building integrated solar thermal (BIST) technologies and their applications : A review of structural design and architectural integration
  • 2015
  • Ingår i: Journal of Fundamentals of Renewable Energy and Applications. - : OMICS Publishing Group. - 2090-4533 .- 2090-4541. ; 5:5, s. 1-21
  • Tidskriftsartikel (refereegranskat)abstract
    • Solar energy has enormous potential to meet the majority of present world energy demand by effective integration with local building components. One of the most promising technologies is building integrated solar thermal (BIST) technology. This paper presents a review of the available literature covering various types of BIST technologies and their applications in terms of structural design and architectural integration. The review covers detailed description of BIST systems using air, hydraulic (water/heat pipe/refrigerant) and phase changing materials (PCM) as the working medium. The fundamental structure of BIST and the various specific structures of available BIST in the literature are described. Design criteria and practical operation conditions of BIST systems are illustrated. The state of pilot projects is also fully depicted. Current barriers and future development opportunities are therefore concluded. Based on the thorough review, it is clear that BIST is very promising devices with considerable energy saving prospective and building integration feasibility. This review shall facilitate the development of solar driven service for buildings and help the corresponding saving in fossil fuel consumption and the reduction in carbon emission.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy