SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Akselsson Roland) srt2:(1975-1979);pers:(Winchester John W)"

Sökning: WFRF:(Akselsson Roland) > (1975-1979) > Winchester John W

  • Resultat 1-10 av 12
  • [1]2Nästa
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Akselsson, Roland, et al. (författare)
  • Application of Proton Induced X-Ray Emission Analysis to the St. Louis Regional Air Pollution Study
  • 1975
  • Ingår i: Advances in X-Ray Analysis. - Plenum Publishing Corporation, New York, USA. ; 18, s. 588-597
  • Tidskriftsartikel (refereegranskat)abstract
    • The St Louis aerosol was sampled during the period 16-22 August 1973 simultaneously at two locations using cascade impactors for sequential 12-hour samples. The six particle size fractions of each sampling were individually analyzed using PIXE for elements from S to Br and beyond and for heavy elements including Pb which permitted time variations of concentrations and particle size distributions to be followed and related to meteorological changes during the sampling period. In addition, the data were compared with average levels of the elements in coastal north Florida and maritime Bermuda as well as at a third St. Louis site. From this it appeared that some of the concentrations in St. Louis were at natural levels whereas others appeared to be higher and linked to air pollution sources. These relationships and others in this study may lead to criteria for distinguishing between pollutants and natural background in urban aerosols.
  •  
2.
  • Akselsson, Roland, et al. (författare)
  • Particle Size Distribution and Human Respiratory Deposition of Trace Metals in Indoor Work Environments
  • 1976
  • Ingår i: Annals of Occupational Hygiene. - Pergamon Press. - 0003-4878 .- 1475-3162. ; 19:3-4, s. 225-238
  • Tidskriftsartikel (refereegranskat)abstract
    • Respiratory response to inhalation of fine particles has been investigated for the aerosol generated by welding. Particles were sampled using a pair of 5-stage cascade impactors operating at 1 l./min flow rate. The subject exhaled into one impactor through an air ballast arrangement, and the other impactor simultaneously sampled the surrounding air. Particle size fractions were analyzed for principal elemental constituents from sulphur to lead using proton induced X-ray emission, PIXE. The results indicated a complex respiratory response, including both increase in particle size due to exposure to high humidity in the respiratory tract and deposition of particles during inhalation. The response was found to be different for the element group Mn, Cr, Fe, Ni compared to the group K, Ca, Ti by observing the associations among the elements as a function of particle size in the inhaled and exhaled aerosol. However, for respiratory deposition efficiency alone in all runs averaged together, no systematic differences between the different elements are demonstrated at the 99 % confidence level.
3.
  • Akselsson, Roland, et al. (författare)
  • Proton Scattering for Analysis of Atmospheric Particulate Matter
  • 1975
  • Ingår i: Bulletin of the American Physical Society Ser II. ; 20
  • Tidskriftsartikel (refereegranskat)abstract
    • Proton scattering has been applied to the problem of elemental quantitative analysis of air particulate matter. Elements up through chlorine may be resolved using 16 MeV protons incident upon targets up to about 1 mg/cm2 in thickness. Using the FSU Super FM Tandem Accelerator and a large area solid state proton detector, an analysis can be performed in several minutes. Combination of this technique with proton induced X-ray emission analysis provides a means of quantitative analysis for all elements. These accelerator based methods are being applied to studies of the composition of air particulate matter in diverse locations such as St. Louis, Mo.; Los Angeles, Ca.; several cities in Florida; and Bermuda.
  •  
4.
  • Akselsson, Roland, et al. (författare)
  • X-Ray Techniques for Aerosol Sulfur Baseline Assessment Along an Urban Freeway
  • 1976
  • Ingår i: Advances in X-Ray Analysis. - Kendall/Hunt Publishing Co, Dubuque, Iowa, USA. ; 19, s. 415-425
  • Tidskriftsartikel (refereegranskat)abstract
    • Atmospheric aerosol particles have been sampled near a Los Angeles freeway and analyzed by proton-induced X-ray emission, PIXE, as a sulfur baseline study in September 1974 before 1975-model automobiles, equipped with catalytic emission control devices, appeared in large numbers. The sampling plan was optimized according to the requirements of X-ray analysis techniques, fluctuations in air flow across the freeway, and the time and particle size resolution of the aerosol sampling equipment. During five selected two-hour intervals with cross wind conditions, particles were collected as a function of size by six cascade impactors operating simultaneously on three towers at 2 and 7 meters above road level 35 meters upwind and 35 meters downwind of the traffic lanes. Particles as a function of time were sampled continuously, for the 100-hour duration of the experiment, from the tree 7-meter heights using time series streaker filter samplers with two-hour time resolution. Precise analysis of S, Cl, K, Ca, Fe, Br, and Pb established relationships which permit estimates to be made of future increases in particulate sulfur as a consequence of increased sulfate emissions from catalytic automobiles
  •  
5.
  •  
6.
  • Desaedeleer, Georges G, et al. (författare)
  • Monitoring Aerosol Elemental Composition in Particle Size Fractions for Predicting Human Respiratory Uptake
  • 1977
  • Ingår i: Nuclear Instruments and Methods. - North-Holland Publishing Co.. - 0029554x. ; 142:1-2, s. 97-99
  • Tidskriftsartikel (refereegranskat)abstract
    • Proton induced X-ray emission analysis is useful in measuring changes in particle size distribution of trace elements on exposure of aerosol to the human lung environment and deposition in the air-ways. PIXE analysis is also useful in detecting variations in particle size distributions of elements as they occur in the atmosphere. For the case of lead aerosol along a highway, it is shown that the extent and site of respiratory deposition of particles depend on their size, and the size distribution may vary under urban atmospheric conditions sufficiently to affect respiratory deposition efficiency.
  •  
7.
  •  
8.
  • Hardy, Kenneth A., et al. (författare)
  • Elemental Constituents of Miami Aerosol as Function of Particle Size
  • 1976
  • Ingår i: Environmental Science & Technology. ; 10:2, s. 176-182
  • Tidskriftsartikel (refereegranskat)abstract
    • Results are presented of proton-induced x-ray emission analysis of aerosol samples taken in Miami, Fla., in the summer of 1974. Elemental concentrations and elemental ratios as a function of particle size are shown for 13 elements. These size distributions allow the determination of the sources of several elements observed in the Miami aerosol. Data from north Florida and Bermuda are compared.
  •  
9.
  • Nelson, J William, et al. (författare)
  • Automatic Time Sequence Filter Sampling of Aerosols for Rapid Multi-Element Analysis by Proton-Induced X-Ray Emission
  • 1976
  • Ingår i: Advances in X-Ray Analysis. - Kendall/Hunt Publishing Co, Dubuque, Iowa, USA. ; 19, s. 403-413
  • Tidskriftsartikel (refereegranskat)abstract
    • An automatic time sequence filter sampler has been developed for atmospheric aerosol particle sampling of ambient air and subsequent analysis for elemental composition using the proton beam of a Van de Graaff accelerator. Some features of the operation of the sampler are given, the retention of particles by the filter material are discussed, examples of the type of data obtained are presented, and some approaches to the numerical analysis of data for environmental interpretation are considered. Lines for further development and improvement in this type of sampler are indicated.
  •  
10.
  • Orsini, Celso Q, et al. (författare)
  • Variation of Elemental Composition with Particle Size in the St. Louis Aerosol
  • 1977
  • Ingår i: Nuclear Instruments and Methods. - North-Holland Publishing Company. ; 142:1-2, s. 91-96
  • Tidskriftsartikel (refereegranskat)abstract
    • Detailed particle size distribution of elemental constituents have been determined in the St. Louis aerosol by sampling with cascade impactors for particles >0.25 μm aerodynamic diameter and by analyzing using proton-induced X-ray emission, PIXE, for S, Cl, K, Ca, Ti, Mn, Fe, Zn, Br, and Pb. Two rooftop sites were selected for intensive sampling in industrial and residential locations in St. Louis during February 1974, every 12 h for a 7 d period which included clear, rainy, and snowy weather regimes. The data could be compared with the results of a similar study of the St. Louis aerosol during August 1973 when the weather was generally warm and without rain. Both data sets could also be compared with results of studies of Tallahassee, situated in coastal north Florida, and the north Atlantic marine atmosphere of Bermuda. Although variation in elemental concentrations and their size distributions were observed which could be associated with local weather conditions during the February sampling period, the data set was sufficiently large for meaningful average characteristics to be computed. As examples, two elements of pollution importance, sulfur and iron, show the following comparison between St. Louis and the Florida and Atlantic locations: Sulfur in all data sets was most abundant in the smallest particle size classes. Winter and summer concentration in St. Louis air were the same within a factor of two but generally exceeded north Florida concentrations. Bermuda concentrations were intermediate between St. Louis and north Florida, except for largest particles where sea spray derived material was present. The results reflect the importance of gas phase conversion to particulate forms of sulfur, e.g. sulfate, in all three locations. Iron concentrations in St. Louis generally exceeded those in north Florida for smallest particles and to a lesser extent for larger sizes. Concentrations in Bermuda were about 10-fold lower than in St. Louis for all particle sizes. The results reflect the terrestrial dust origin of iron and also suggest that iron is partially pollution-derived in the St. Louis atmosphere, especially in smaller size ranges.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12
  • [1]2Nästa
 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy