SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Beale P) srt2:(2020)"

Sökning: WFRF:(Beale P) > (2020)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Beale, S. B., et al. (författare)
  • Combined two-phase co-flow and counter-flow in a gas channel/porous transport layer assembly
  • 2020. - 9
  • Ingår i: PRiME 2020 : Polymer Electrolyte Fuel Cells and Electrolyzers 20 (PEFC and E 20) - Polymer Electrolyte Fuel Cells and Electrolyzers 20 (PEFC and E 20). - : The Electrochemical Society. - 1938-5862 .- 1938-6737. - 9781607685395 ; 98:9, s. 305-315
  • Konferensbidrag (refereegranskat)abstract
    • This paper considers a detailed numerical analysis of combined liquid-gas co-flow in a gas channel, with liquid-gas counter-flow in a porous transport layer, as is typically found on the cathode side of a polymer electrolyte fuel cell. The geometry is obtained by digital reconstruction of nano-computer tomography images. From this, the domain is tessellated with an unstructured castellated or octree mesh, upon which the equations of mass and momentum are solved by means of a volume of fluid method. Liquid water is produced from an electrode where gaseous oxygen is simultaneously consumed by electrochemical reduction; Liquid-gas counter flow in the porous transport layer results in liquid drops being entrained in co-flow in the gas channels and convected by the gas downstream.
  •  
2.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy